Literature DB >> 26863653

Feasibility of Swept Synthetic Aperture Ultrasound Imaging.

Nick Bottenus, Will Long, Haichong K Zhang, Marko Jakovljevic, David P Bradway, Emad M Boctor, Gregg E Trahey.   

Abstract

Ultrasound image quality is often inherently limited by the physical dimensions of the imaging transducer. We hypothesize that, by collecting synthetic aperture data sets over a range of aperture positions while precisely tracking the position and orientation of the transducer, we can synthesize large effective apertures to produce images with improved resolution and target detectability. We analyze the two largest limiting factors for coherent signal summation: aberration and mechanical uncertainty. Using an excised canine abdominal wall as a model phase screen, we experimentally observed an effective arrival time error ranging from 18.3 ns to 58 ns (root-mean-square error) across the swept positions. Through this clutter-generating tissue, we observed a 72.9% improvement in resolution with only a 3.75 dB increase in side lobe amplitude compared to the control case. We present a simulation model to study the effect of calibration and mechanical jitter errors on the synthesized point spread function. The relative effects of these errors in each imaging dimension are explored, showing the importance of orientation relative to the point spread function. We present a prototype device for performing swept synthetic aperture imaging using a conventional 1-D array transducer and ultrasound research scanner. Point target reconstruction error for a 44.2 degree sweep shows a reconstruction precision of 82.8 μm and 17.8 μm in the lateral and axial dimensions respectively, within the acceptable performance bounds of the simulation model. Improvements in resolution, contrast and contrast-to-noise ratio are demonstrated in vivo and in a fetal phantom.

Entities:  

Mesh:

Year:  2016        PMID: 26863653      PMCID: PMC5485828          DOI: 10.1109/TMI.2016.2524992

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  21 in total

1.  Three-dimensional synthetic aperture focusing using a rocking convex array transducer.

Authors:  Henrik Andresen; Svetoslav Ivanov Nikolov; Mads Møller Pedersen; Daniel Buckton; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2010-05       Impact factor: 2.725

2.  Speckle tracking in a phantom and feature-based tracking in liver in the presence of respiratory motion using 4D ultrasound.

Authors:  Emma J Harris; Naomi R Miller; Jeffrey C Bamber; J Richard N Symonds-Tayler; Philip M Evans
Journal:  Phys Med Biol       Date:  2010-05-26       Impact factor: 3.609

3.  In-vivo evaluation of convex array synthetic aperture imaging.

Authors:  Morten H Pedersen; Kim L Gammelmark; Jørgen A Jensen
Journal:  Ultrasound Med Biol       Date:  2007-01       Impact factor: 2.998

4.  Estimation and correction of ultrasonic wavefront distortion using pulse-echo data received in a two-dimensional aperture.

Authors:  D D Liu; R C Waag
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

5.  Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming.

Authors:  G R Lockwood; J R Talman; S S Brunke
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

6.  The application of k-space in pulse echo ultrasound.

Authors:  W F Walker; G E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

7.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

8.  US extended-field-of-view imaging technology.

Authors:  L Weng; A P Tirumalai; C M Lowery; L F Nock; D E Gustafson; P L Von Behren; J H Kim
Journal:  Radiology       Date:  1997-06       Impact factor: 11.105

9.  In vivo and in vitro ultrasound beam distortion measurements of a large aperture and a conventional aperture focussed transducer.

Authors:  M Moshfeghi; R C Waag
Journal:  Ultrasound Med Biol       Date:  1988       Impact factor: 2.998

10.  Compounding in synthetic aperture imaging.

Authors:  Jens Munk Hansen; Jørgen Arendt Jensen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-09       Impact factor: 2.725

View more
  10 in total

1.  Toward dynamic lumbar puncture guidance using needle-based single-element ultrasound imaging.

Authors:  Haichong K Zhang; Younsu Kim; Melissa Lin; Mateo Paredes; Karun Kannan; Abhay Moghekar; Nicholas J Durr; Emad M Boctor
Journal:  J Med Imaging (Bellingham)       Date:  2018-04-02

2.  Phantom with multiple active points for ultrasound calibration.

Authors:  Haichong K Zhang; Alexis Cheng; Younsu Kim; Qianli Ma; Gregory S Chirikjian; Emad M Boctor
Journal:  J Med Imaging (Bellingham)       Date:  2018-11-27

3.  Coherent Multi-Transducer Ultrasound Imaging.

Authors:  Laura Peralta; Alberto Gomez; Ying Luan; Bae-Hyung Kim; Joseph V Hajnal; Robert J Eckersley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-06-05       Impact factor: 2.725

4.  Dual-Resonance (16/32 MHz) Piezoelectric Transducer With a Single Electrical Connection for Forward-Viewing Robotic Guidewire.

Authors:  Graham C Collins; Timothy A Brumfiel; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

5.  A novel design framework of synthetic radial aperture focusing for volumetric transrectal ultrasound imaging.

Authors:  Hyunwoo Song; Jeeun Kang; Emad M Boctor
Journal:  J Comput Des Eng       Date:  2022-08-24

6.  Evaluation of Large-Aperture Imaging Through the ex Vivo Human Abdominal Wall.

Authors:  Nick Bottenus; Will Long; Matthew Morgan; Gregg Trahey
Journal:  Ultrasound Med Biol       Date:  2017-12-14       Impact factor: 2.998

7.  A Robotically Steerable Guidewire With Forward-Viewing Ultrasound: Development of Technology for Minimally-Invasive Imaging.

Authors:  Graham C Collins; Achraj Sarma; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.756

8.  Sub-wavelength lateral detection of tissue-approximating masses using an ultrasonic metamaterial lens.

Authors:  Ezekiel L Walker; Yuqi Jin; Delfino Reyes; Arup Neogi
Journal:  Nat Commun       Date:  2020-11-24       Impact factor: 14.919

9.  Highly Integrated Multiplexing and Buffering Electronics for Large Aperture Ultrasonic Arrays.

Authors:  Robert Wodnicki; Haochen Kang; Di Li; Douglas N Stephens; Hayong Jung; Yizhe Sun; Ruimin Chen; Lai-Ming Jiang; Nestor E Cabrera-Munoz; Josquin Foiret; Qifa Zhou; Katherine W Ferrara
Journal:  BME Front       Date:  2022-06-30

10.  Improving plane wave ultrasound imaging through real-time beamformation across multiple arrays.

Authors:  Josquin Foiret; Xiran Cai; Hanna Bendjador; Eun-Yeong Park; Aya Kamaya; Katherine W Ferrara
Journal:  Sci Rep       Date:  2022-08-04       Impact factor: 4.996

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.