Literature DB >> 29651451

Toward dynamic lumbar puncture guidance using needle-based single-element ultrasound imaging.

Haichong K Zhang1, Younsu Kim1, Melissa Lin2, Mateo Paredes3, Karun Kannan3, Abhay Moghekar4, Nicholas J Durr2,3, Emad M Boctor1,2,5.   

Abstract

Lumbar punctures (LPs) are interventional procedures that are used to collect cerebrospinal fluid. Since the target window is small, physicians have limited success conducting the procedure. The procedure is especially difficult for obese patients due to the increased distance between bone and skin surface. We propose a simple and direct needle insertion platform, enabling image formation by sweeping a needle with a single ultrasound element at the tip. The needle-shaped ultrasound transducer can not only sense the distance between the tip and a potential obstacle, such as bone, but also visually locate the structures by combining transducer location tracking and synthetic aperture focusing. The concept of the system was validated through a simulation that revealed robust image reconstruction under expected errors in tip localization. The initial prototype was built into a 14 G needle and was mounted on a holster equipped with a rotation shaft allowing one degree-of-freedom rotational sweeping and a rotation tracking encoder. We experimentally evaluated the system using a metal-wire phantom mimicking high reflection bone structures and human spinal bone phantom. Images of the phantoms were reconstructed, and the synthetic aperture reconstruction improved the image quality. These results demonstrate the potential of the system to be used as a real-time guidance tool for improving LPs.

Entities:  

Keywords:  lumbar puncture guidance; synthetic aperture; ultrasound imaging; ultrasound needle

Year:  2018        PMID: 29651451      PMCID: PMC5879152          DOI: 10.1117/1.JMI.5.2.021224

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  18 in total

1.  Eyes in the needle: novel epidural needle with embedded high-frequency ultrasound transducer--epidural access in porcine model.

Authors:  Huihua K Chiang; Qifa Zhou; M Susan Mandell; Mei-Yung Tsou; Shih-Pin Lin; K Kirk Shung; Chien-Kun Ting
Journal:  Anesthesiology       Date:  2011-06       Impact factor: 7.892

2.  Incidence of traumatic lumbar puncture.

Authors:  Kaushal H Shah; Kathleen M Richard; Sarah Nicholas; Jonathan A Edlow
Journal:  Acad Emerg Med       Date:  2003-02       Impact factor: 3.451

3.  Single-Camera Closed-Form Real-Time Needle Tracking for Ultrasound-Guided Needle Insertion.

Authors:  Mohammad Najafi; Purang Abolmaesumi; Robert Rohling
Journal:  Ultrasound Med Biol       Date:  2015-07-26       Impact factor: 2.998

4.  Addendum to assessment: Prevention of post-lumbar puncture headaches: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology.

Authors:  Carmel Armon; Randolph W Evans
Journal:  Neurology       Date:  2005-08-23       Impact factor: 9.910

Review 5.  Synthetic aperture ultrasound imaging.

Authors:  Jørgen Arendt Jensen; Svetoslav Ivanov Nikolov; Kim Løkke Gammelmark; Morten Høgholm Pedersen
Journal:  Ultrasonics       Date:  2006-08-11       Impact factor: 2.890

Review 6.  Evaluation of the eZono 4000 with eZGuide for ultrasound-guided procedures.

Authors:  Jeff Gadsden; Malikah Latmore; Daniel M Levine
Journal:  Expert Rev Med Devices       Date:  2014-12-29       Impact factor: 3.166

Review 7.  Ultrasound imaging for lumbar punctures and epidural catheterisations: systematic review and meta-analysis.

Authors:  Furqan Shaikh; Jack Brzezinski; Sarah Alexander; Cristian Arzola; Jose C A Carvalho; Joseph Beyene; Lillian Sung
Journal:  BMJ       Date:  2013-03-26

8.  Residency training: a failed lumbar puncture is more about obesity than lack of ability.

Authors:  Cory Edwards; Enrique C Leira; Pedro Gonzalez-Alegre
Journal:  Neurology       Date:  2015-03-10       Impact factor: 9.910

9.  Image guidance for spinal facet injections using tracked ultrasound.

Authors:  John Moore; Colin Clarke; Daniel Bainbridge; Chris Wedlake; Andrew Wiles; Danielle Pace; Terry Peters
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

10.  Antibiotic treatment delay and outcome in acute bacterial meningitis.

Authors:  Rasmus Køster-Rasmussen; André Korshin; Christian N Meyer
Journal:  J Infect       Date:  2008-11-09       Impact factor: 6.072

View more
  3 in total

1.  Dual-Resonance (16/32 MHz) Piezoelectric Transducer With a Single Electrical Connection for Forward-Viewing Robotic Guidewire.

Authors:  Graham C Collins; Timothy A Brumfiel; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

2.  A Robotically Steerable Guidewire With Forward-Viewing Ultrasound: Development of Technology for Minimally-Invasive Imaging.

Authors:  Graham C Collins; Achraj Sarma; Zachary L Bercu; Jaydev P Desai; Brooks D Lindsey
Journal:  IEEE Trans Biomed Eng       Date:  2021-06-17       Impact factor: 4.756

3.  Actuated Reflector-Based 3-D Ultrasound Imaging With Synthetic Aperture Focusing.

Authors:  Yichuan Tang; Ryosuke Tsumura; Jakub Tomasz Kaminski; Haichong K Zhang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-07-29       Impact factor: 3.267

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.