Literature DB >> 35143395

Dual-Resonance (16/32 MHz) Piezoelectric Transducer With a Single Electrical Connection for Forward-Viewing Robotic Guidewire.

Graham C Collins, Timothy A Brumfiel, Zachary L Bercu, Jaydev P Desai, Brooks D Lindsey.   

Abstract

Peripheral artery disease (PAD) affects more than 200 million people globally. Minimally invasive endovascular procedures can provide relief and salvage limbs while reducing injury rates and recovery times. Unfortunately, when a calcified chronic total occlusion is encountered, ~25% of endovascular procedures fail due to the inability to advance a guidewire using the view provided by fluoroscopy. To enable a sub-millimeter, robotically steerable guidewire to cross these occlusions, a novel single-element, dual-band transducer is developed that provides simultaneous multifrequency, forward-viewing imaging with high penetration depth and high spatial resolution while requiring only a single electrical connection. The design, fabrication, and acoustic characterization of this device are described, and proof-of-concept imaging is demonstrated in an ex vivo porcine artery after integration with a robotically steered guidewire. Measured center frequencies of the developed transducer were 16 and 32 MHz, with -6 dB fractional bandwidths of 73% and 23%, respectively. When imaging a 0.2-mm wire target at a depth of 5 mm, measured -6 dB target widths were 0.498 ± 0.02 and 0.268 ± 0.01 mm for images formed at 16 and 32 MHz, respectively. Measured SNR values were 33.3 and 21.3 dB, respectively. The 3-D images of the ex vivo artery demonstrate high penetration for visualizing vessel morphology at 16 MHz and ability to resolve small features close to the transducer at 32 MHz. Using images acquired simultaneously at both frequencies as part of an integrated forward-viewing, guidewire-based imaging system, an interventionalist could visualize the best path for advancing the guidewire to improve outcomes for patients with PAD.

Entities:  

Mesh:

Year:  2022        PMID: 35143395      PMCID: PMC9013008          DOI: 10.1109/TUFFC.2022.3150746

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   3.267


  70 in total

1.  Annular-ring CMUT arrays for forward-looking IVUS: transducer characterization and imaging.

Authors:  F Levent Degertekin; Rasim O Guldiken; Mustafa Karaman
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-02       Impact factor: 2.725

2.  An Improved CMUT Structure Enabling Release and Collapse of the Plate in the Same Tx/Rx Cycle for Dual-Frequency Acoustic Angiography.

Authors:  Marzana Mantasha Mahmud; Xun Wu; Jean Lunsford Sanders; Ali Onder Biliroglu; Oluwafemi Joel Adelegan; Isabel G Newsome; Feysel Yalcin Yamaner; Paul A Dayton; Omer Oralkan
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-06-09       Impact factor: 2.725

Review 3.  Peripheral artery disease: epidemiology and global perspectives.

Authors:  F Gerry R Fowkes; Victor Aboyans; Freya J I Fowkes; Mary M McDermott; Uchechukwu K A Sampson; Michael H Criqui
Journal:  Nat Rev Cardiol       Date:  2016-11-17       Impact factor: 32.419

4.  A Dual-Frequency Colinear Array for Acoustic Angiography in Prostate Cancer Evaluation.

Authors:  Sibo Li; Jinwook Kim; Zhuochen Wang; Sandeep Kasoji; Brooks D Lindsey; Paul A Dayton; Xiaoning Jiang
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

5.  Two-year results after directional atherectomy of infrapopliteal arteries with the SilverHawk device.

Authors:  Thomas Zeller; Sebastian Sixt; Uwe Schwarzwälder; Thomas Schwarz; Ulrich Frank; Karlheinz Bürgelin; Volker Pochert; Christian Müller; Elias Noory; Hans Krankenberg; Kirsten Hauswald; Franz-Josef Neumann; Aljoscha Rastan
Journal:  J Endovasc Ther       Date:  2007-04       Impact factor: 3.487

6.  Synthetic receive aperture imaging with phase correction for motion and for tissue inhomogeneities. II. Effects of and correction for motion.

Authors:  G E Trahey; L F Nock
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

7.  Implementation of a Novel 288-Element Dual-Frequency Array for Acoustic Angiography: In Vitro and In Vivo Characterization.

Authors:  Isabel G Newsome; Thomas M Kierski; Guofeng Pang; Jianhua Yin; Jing Yang; Emmanuel Cherin; F Stuart Foster; Claudia A Carnevale; Christine E M Demore; Paul A Dayton
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-07-26       Impact factor: 3.267

8.  Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging.

Authors:  K Heath Martin; Brooks D Lindsey; Jianguo Ma; Mike Lee; Sibo Li; F Stuart Foster; Xiaoning Jiang; Paul A Dayton
Journal:  Sensors (Basel)       Date:  2014-11-04       Impact factor: 3.576

Review 9.  Advances in Revascularization for Peripheral Artery Disease: Revascularization in PAD.

Authors:  Joshua A Beckman; Peter A Schneider; Michael S Conte
Journal:  Circ Res       Date:  2021-06-10       Impact factor: 17.367

10.  A 35 MHz/105 MHz Dual-Element Focused Transducer for Intravascular Ultrasound Tissue Imaging Using the Third Harmonic.

Authors:  Junsu Lee; Ju-Young Moon; Jin Ho Chang
Journal:  Sensors (Basel)       Date:  2018-07-15       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.