Literature DB >> 18244252

Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming.

G R Lockwood1, J R Talman, S S Brunke.   

Abstract

A method for real-time three-dimensional (3-D) ultrasound imaging using a mechanically scanned linear phased array is proposed. The high frame rate necessary for real-time volumetric imaging is achieved using a sparse synthetic aperture beamforming technique utilizing only a few transmit pulses for each image. Grating lobes in the two-way radiation pattern are avoided by adjusting the transmit element spacing and the receive aperture functions to account for the missing transmit elements. The signal loss associated with fewer transmit pulses is minimized by increasing the power delivered to each transmit element and by using multiple transmit elements for each transmit pulse. By mechanically rocking the array, in a way similar to what is done with an annular array, a 3-D set of images can be collected in the time normally required for a single image.

Year:  1998        PMID: 18244252     DOI: 10.1109/58.710573

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  14 in total

1.  2-D array for 3-D ultrasound imaging using synthetic aperture techniques.

Authors:  Nadim M Daher; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-05       Impact factor: 2.725

2.  Angular coherence in ultrasound imaging: Theory and applications.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2017-03       Impact factor: 1.840

3.  High-resolution real-time three-dimensional acoustic imaging system with a reflector.

Authors:  Hirofumi Taki; Toru Sato
Journal:  J Med Ultrason (2001)       Date:  2007-09-14       Impact factor: 1.314

4.  Impact of element pitch on synthetic aperture ultrasound imaging.

Authors:  Hideyuki Hasegawa; Chris L de Korte
Journal:  J Med Ultrason (2001)       Date:  2016-02-20       Impact factor: 1.314

5.  Application of X-Y separable 2-D array beamforming for increased frame rate and energy efficiency in handheld devices.

Authors:  Kevin Owen; Michael Fuller; John Hossack
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-07       Impact factor: 2.725

6.  Feasibility of Swept Synthetic Aperture Ultrasound Imaging.

Authors:  Nick Bottenus; Will Long; Haichong K Zhang; Marko Jakovljevic; David P Bradway; Emad M Boctor; Gregg E Trahey
Journal:  IEEE Trans Med Imaging       Date:  2016-02-03       Impact factor: 10.048

7.  Design of a Volumetric Imaging Sequence Using a Vantage-256 Ultrasound Research Platform Multiplexed With a 1024-Element Fully Sampled Matrix Array.

Authors:  Jaesok Yu; Heechul Yoon; Yousuf M Khalifa; Stanislav Y Emelianov
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-09-19       Impact factor: 2.725

8.  3-D ultrafast Doppler imaging applied to the noninvasive mapping of blood vessels in vivo.

Authors:  Jean Provost; Clement Papadacci; Charlie Demene; Jean-Luc Gennisson; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-08       Impact factor: 2.725

9.  High-contrast ultrafast imaging of the heart.

Authors:  Clement Papadacci; Mathieu Pernot; Mathieu Couade; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-02       Impact factor: 2.725

10.  Transthoracic ultrafast Doppler imaging of human left ventricular hemodynamic function.

Authors:  Bruno-Felix Osmanski; David Maresca; Emmanuel Messas; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-08       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.