Coherent Multi-Transducer Ultrasound Imaging.

Laura Peralta, Alberto Gomez, Ying Luan, Bae-Hyung Kim, Joseph V Hajnal, Robert J Eckersley.   

Abstract

This work extends the effective aperture size by coherently compounding the received radio frequency data from multiple transducers. As a result, it is possible to obtain an improved image, with enhanced resolution, an extended field of view (FoV), and high-acquisition frame rates. A framework is developed in which an ultrasound imaging system consisting of N synchronized matrix arrays, each with partly shared FoV, take turns to transmit plane waves (PWs). Only one individual transducer transmits at each time while all N transducers simultaneously receive. The subwavelength localization accuracy required to combine information from multiple transducers is achieved without the use of any external tracking device. The method developed in this study is based on the study of the backscattered echoes received by the same transducer and resulting from a targeted scatterer point in the medium insonated by the multiple ultrasound probes of the system. The current transducer locations along with the speed of sound in the medium are deduced by optimizing the cross correlation between these echoes. The method is demonstrated experimentally in 2-D for two linear arrays using point targets and anechoic lesion phantoms. The first demonstration of a free-hand experiment is also shown. Results demonstrate that the coherent multi-transducer ultrasound imaging method has the potential to improve ultrasound image quality, improving resolution, and target detectability. Compared with coherent PW compounding using a single probe, lateral resolution improved from 1.56 to 0.71 mm in the coherent multi-transducer imaging method without acquisition frame rate sacrifice (acquisition frame rate 5350 Hz).

Entities:  

Year:  2019        PMID: 31180847      PMCID: PMC7115943          DOI: 10.1109/TUFFC.2019.2921103

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  29 in total

Review 1.  A review of calibration techniques for freehand 3-D ultrasound systems.

Authors:  Laurence Mercier; Thomas Langø; Frank Lindseth; Louis D Collins
Journal:  Ultrasound Med Biol       Date:  2005-02       Impact factor: 2.998

2.  Estimation and correction of ultrasonic wavefront distortion using pulse-echo data received in a two-dimensional aperture.

Authors:  D D Liu; R C Waag
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1998       Impact factor: 2.725

3.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography.

Authors:  Gabriel Montaldo; Mickaël Tanter; Jérémy Bercoff; Nicolas Benech; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

4.  The direct estimation of sound speed using pulse-echo ultrasound.

Authors:  M E Anderson; G E Trahey
Journal:  J Acoust Soc Am       Date:  1998-11       Impact factor: 1.840

5.  In vivo acoustic super-resolution and super-resolved velocity mapping using microbubbles.

Authors:  Kirsten Christensen-Jeffries; Richard J Browning; Meng-Xing Tang; Christopher Dunsby; Robert J Eckersley
Journal:  IEEE Trans Med Imaging       Date:  2014-09-23       Impact factor: 10.048

6.  A closed-form differential formulation for ultrasound spatial calibration: multi-wedge phantom.

Authors:  Mohammad Najafi; Narges Afsham; Purang Abolmaesumi; Robert Rohling
Journal:  Ultrasound Med Biol       Date:  2014-06-07       Impact factor: 2.998

7.  Microbubble Axial Localization Errors in Ultrasound Super-Resolution Imaging.

Authors:  Kirsten Christensen-Jeffries; Sevan Harput; Jemma Brown; Peter N T Wells; Paul Aljabar; Christopher Dunsby; Meng-Xing Tang; Robert J Eckersley
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-08-17       Impact factor: 2.725

8.  Acoustic reciprocity of spatial coherence in ultrasound imaging.

Authors:  Nick Bottenus; Kutay F Üstüner
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-05       Impact factor: 2.725

9.  ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods.

Authors:  Enrico Boni; Luca Bassi; Alessandro Dallai; Francesco Guidi; Valentino Meacci; Alessandro Ramalli; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-11       Impact factor: 2.725

10.  Evaluation of Large-Aperture Imaging Through the ex Vivo Human Abdominal Wall.

Authors:  Nick Bottenus; Will Long; Matthew Morgan; Gregg Trahey
Journal:  Ultrasound Med Biol       Date:  2017-12-14       Impact factor: 2.998

View more
  2 in total

1.  Modeling toolchain for realistic simulation of photoacoustic data acquisition.

Authors:  Jan-Willem Muller; Mustafa Ü Arabul; Hans-Martin Schwab; Marcel C M Rutten; Marc R H M van Sambeek; Min Wu; Richard G P Lopata
Journal:  J Biomed Opt       Date:  2022-09       Impact factor: 3.758

2.  Improving plane wave ultrasound imaging through real-time beamformation across multiple arrays.

Authors:  Josquin Foiret; Xiran Cai; Hanna Bendjador; Eun-Yeong Park; Aya Kamaya; Katherine W Ferrara
Journal:  Sci Rep       Date:  2022-08-04       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.