Literature DB >> 26855407

Assessment of renal function using intravoxel incoherent motion diffusion-weighted imaging and dynamic contrast-enhanced MRI.

Octavia Bane1, Mathilde Wagner1, Jeff L Zhang2, Hadrien A Dyvorne1, Matthew Orton3, Henry Rusinek4, Bachir Taouli1,5.   

Abstract

PURPOSE: To assess the correlation between each of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in renal parenchyma with renal function, in a cohort of patients with chronic liver disease.
MATERIALS AND METHODS: Thirty patients with liver disease underwent abdominal MRI at 1.5T, including a coronal respiratory-triggered IVIM-DWI sequence and a coronal 3D FLASH DCE-MRI acquisition. Diffusion signals in the renal cortex and medulla were fitted to the IVIM model to estimate the diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF). The apparent diffusion coefficient (ADC) was calculated using all b-values. The glomerular filtration rate (GFR), cortical and medullary renal plasma flow (RPF), mean transit times (MTT) of vascular and tubular compartments and the whole kidney, were calculated from DCE-MRI data by fitting to a three-compartment model. The estimated GFR (eGFR) was calculated from serum creatinine measured 30 ± 27 days of MRI.
RESULTS: ADC, PF, and RPF were significantly higher in renal cortex vs. medulla (P < 10(-5) ). DCE-MRI GFR significantly correlated with, but underestimated, eGFR (Spearman's r/P = 0.49/0.01). IVIM-DWI parameters were not significantly correlated with eGFR. DCE-MRI GFR correlated weakly with D (cortex, r/P = 0.3/0.03; medulla r/P = 0.27/0.05) and ADC (cortex r/P = 0.28/0.04; medulla r/P = 0.34/0.01). Weak correlations were observed for pooled cortical and medullar RPF with PF (r/P = 0.32/10(-3) ) and with ADC (r/P = 0.29/0.0025). Significant negative correlations were observed for vascular MTT with cortical D* (r/P = -0.38/0.004) and D*×PF (r/P = -0.34/0.01).
CONCLUSION: The weak correlations between renal IVIM and DCE-MRI perfusion parameters imply that these functional measures could be complementary. J. Magn. Reson. Imaging 2016;44:317-326.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  IVIM; renal DCE-MRI; renal DWI-MRI; renal function in liver disease

Mesh:

Substances:

Year:  2016        PMID: 26855407      PMCID: PMC4946973          DOI: 10.1002/jmri.25171

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  28 in total

1.  Renal function measurements from MR renography and a simplified multicompartmental model.

Authors:  Vivian S Lee; Henry Rusinek; Louisa Bokacheva; Ambrose J Huang; Niels Oesingmann; Qun Chen; Manmeen Kaur; Keyma Prince; Ting Song; Elissa L Kramer; Edward F Leonard
Journal:  Am J Physiol Renal Physiol       Date:  2007-01-09

2.  Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.

Authors:  D Le Bihan; E Breton; D Lallemand; M L Aubin; J Vignaud; M Laval-Jeantet
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

3.  Demonstration of nonlinearity bias in the measurement of the apparent diffusion coefficient in multicenter trials.

Authors:  Dariya I Malyarenko; David Newitt; Lisa J Wilmes; Alina Tudorica; Karl G Helmer; Lori R Arlinghaus; Michael A Jacobs; Guido Jajamovich; Bachir Taouli; Thomas E Yankeelov; Wei Huang; Thomas L Chenevert
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

4.  DCE-MRI of the liver: effect of linear and nonlinear conversions on hepatic perfusion quantification and reproducibility.

Authors:  Shimon Aronhime; Claudia Calcagno; Guido H Jajamovich; Hadrien Arezki Dyvorne; Philip Robson; Douglas Dieterich; M Isabel Fiel; Valérie Martel-Laferriere; Manjil Chatterji; Henry Rusinek; Bachir Taouli
Journal:  J Magn Reson Imaging       Date:  2013-11-04       Impact factor: 4.813

5.  Diffusion-weighted MR imaging of kidneys in healthy volunteers and patients with parenchymal diseases: initial experience.

Authors:  Harriet C Thoeny; Frederik De Keyzer; Raymond H Oyen; Ronald R Peeters
Journal:  Radiology       Date:  2005-04-21       Impact factor: 11.105

6.  Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI.

Authors:  D Baumann; M Rudin
Journal:  Magn Reson Imaging       Date:  2000-06       Impact factor: 2.546

7.  Hepatic MR Elastography: Clinical Performance in a Series of 1377 Consecutive Examinations.

Authors:  Meng Yin; Kevin J Glaser; Jayant A Talwalkar; Jun Chen; Armando Manduca; Richard L Ehman
Journal:  Radiology       Date:  2015-07-08       Impact factor: 11.105

8.  Diffusion-weighted imaging of the liver with multiple b values: effect of diffusion gradient polarity and breathing acquisition on image quality and intravoxel incoherent motion parameters--a pilot study.

Authors:  Hadrien A Dyvorne; Nicola Galea; Thomas Nevers; M Isabel Fiel; David Carpenter; Edmund Wong; Matthew Orton; Andre de Oliveira; Thorsten Feiweier; Marie-Louise Vachon; James S Babb; Bachir Taouli
Journal:  Radiology       Date:  2012-12-06       Impact factor: 11.105

9.  Measurement of single-kidney glomerular filtration rate using a contrast-enhanced dynamic gradient-echo sequence and the Rutland-Patlak plot technique.

Authors:  Nils Hackstein; Jan Heckrodt; Wigbert S Rau
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

10.  Measurement reproducibility of perfusion fraction and pseudodiffusion coefficient derived by intravoxel incoherent motion diffusion-weighted MR imaging in normal liver and metastases.

Authors:  A Andreou; D M Koh; D J Collins; M Blackledge; T Wallace; M O Leach; M R Orton
Journal:  Eur Radiol       Date:  2012-10-06       Impact factor: 5.315

View more
  12 in total

1.  Assessment of unilateral ureter obstruction with multi-parametric MRI.

Authors:  Feng Wang; Keiko Takahashi; Hua Li; Zhongliang Zu; Ke Li; Junzhong Xu; Raymond C Harris; Takamune Takahashi; John C Gore
Journal:  Magn Reson Med       Date:  2017-07-24       Impact factor: 4.668

Review 2.  Functional Magnetic Resonance Imaging of the Kidneys-With and Without Gadolinium-Based Contrast.

Authors:  Jeff L Zhang
Journal:  Adv Chronic Kidney Dis       Date:  2017-05       Impact factor: 3.620

3.  Accuracy, repeatability, and interplatform reproducibility of T1 quantification methods used for DCE-MRI: Results from a multicenter phantom study.

Authors:  Octavia Bane; Stefanie J Hectors; Mathilde Wagner; Lori L Arlinghaus; Madhava P Aryal; Yue Cao; Thomas L Chenevert; Fiona Fennessy; Wei Huang; Nola M Hylton; Jayashree Kalpathy-Cramer; Kathryn E Keenan; Dariya I Malyarenko; Robert V Mulkern; David C Newitt; Stephen E Russek; Karl F Stupic; Alina Tudorica; Lisa J Wilmes; Thomas E Yankeelov; Yi-Fei Yen; Michael A Boss; Bachir Taouli
Journal:  Magn Reson Med       Date:  2017-09-14       Impact factor: 4.668

4.  Magnetic resonance image compilation sequence to quantitatively detect active sacroiliitis with axial spondyloarthritis.

Authors:  Yunping Jiang; Wenjuan Li; Jing Zheng; Ke Zhang; Chaoran Liu; Guobin Hong
Journal:  Quant Imaging Med Surg       Date:  2022-07

5.  Motion-Robust Spatially Constrained Parameter Estimation in Renal Diffusion-Weighted MRI by 3D Motion Tracking and Correction of Sequential Slices.

Authors:  Sila Kurugol; Bahram Marami; Onur Afacan; Simon K Warfield; Ali Gholipour
Journal:  Mol Imaging Reconstr Anal Mov Body Organs Stroke Imaging Treat (2017)       Date:  2017-09-09

6.  Quantitative assessment of renal allograft pathologic changes: comparisons of mono-exponential and bi-exponential models using diffusion-weighted imaging.

Authors:  Min Fan; Zhaoyu Xing; Yanan Du; Liang Pan; Yangyang Sun; Xiaozhou He
Journal:  Quant Imaging Med Surg       Date:  2020-06

7.  Retrospective Distortion and Motion Correction for Free-Breathing DW-MRI of the Kidneys Using Dual-Echo EPI and Slice-to-Volume Registration.

Authors:  Jaume Coll-Font; Onur Afacan; Scott Hoge; Harsha Garg; Kumar Shashi; Bahram Marami; Ali Gholipour; Jeanne Chow; Simon Warfield; Sila Kurugol
Journal:  J Magn Reson Imaging       Date:  2020-12-31       Impact factor: 4.813

8.  Assessment of Correlation between Intravoxel Incoherent Motion Diffusion Weighted MR Imaging and Dynamic Contrast-Enhanced MR Imaging of Sacroiliitis with Ankylosing Spondylitis.

Authors:  Yinghua Zhao; Qun Zhang; Zhiming Xiang; Shaolin Li; Wei Li; Yanqiu Feng; Yihao Guo
Journal:  Biomed Res Int       Date:  2017-12-27       Impact factor: 3.411

9.  Renal Diffusion-Weighted Imaging in Healthy Dogs: Reproducibility, Test-Retest Repeatability, and Selection of the Optimal b-value Combination.

Authors:  Sang-Kwon Lee; Juryeoung Lee; Seolyn Jang; Eunji Lee; Chang-Yeop Jeon; Kyung-Seoub Lim; Yeung Bae Jin; Jihye Choi
Journal:  Front Vet Sci       Date:  2021-07-02

10.  Can introvoxel incoherent motion MRI be used to differentiate patients with placenta accreta spectrum disorders?

Authors:  Tao Lu; Hong Pu; Kui-de Li; Jie Mei; Meng-Wei Huang; Shao-Yu Wang
Journal:  BMC Pregnancy Childbirth       Date:  2019-12-30       Impact factor: 3.007

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.