Literature DB >> 28501079

Functional Magnetic Resonance Imaging of the Kidneys-With and Without Gadolinium-Based Contrast.

Jeff L Zhang1.   

Abstract

Assessment of renal function with magnetic resonance imaging (MRI) has been actively explored in the past decade. In this review, we introduce the principle of MRI and review recent progress of MRI methods (contrast enhanced and noncontrast) in assessing renal function. Contrast-enhanced MRI using ultra-low dose of gadolinium-based agent has been validated for measuring single-kidney glomerular filtration rate and renal plasma flow accurately. For routine functional test, contrast-enhanced MRI may not replace the simple serum-creatinine method. However, for patients with renal diseases, it is often worthy to perform MRI to accurately monitor renal function, particularly for the diseased kidney. As contrast-enhanced MRI is already an established clinical tool for characterizing renal structural abnormalities, including renal mass and ureteral obstruction, it is possible to adapt the clinical MRI protocol to measure single-kidney glomerular filtration rate and renal plasma flow, as demonstrated by recent studies. What makes MRI unique is the promise of its noncontrast methods. These methods include arterial spin labeling for tissue perfusion, blood oxygen-level dependent for blood and tissue oxygenation, and diffusion-weighted imaging for water diffusion. For each method, we reviewed recent findings and summarized challenges.
Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Diffusion coefficient; Glomerular filtration rat; Magnetic resonance imaging; Tissue oxygenation; Tissue perfusion

Mesh:

Substances:

Year:  2017        PMID: 28501079      PMCID: PMC5433253          DOI: 10.1053/j.ackd.2017.03.006

Source DB:  PubMed          Journal:  Adv Chronic Kidney Dis        ISSN: 1548-5595            Impact factor:   3.620


  46 in total

Review 1.  Renal relevant radiology: renal functional magnetic resonance imaging.

Authors:  Behzad Ebrahimi; Stephen C Textor; Lilach O Lerman
Journal:  Clin J Am Soc Nephrol       Date:  2013-12-26       Impact factor: 8.237

2.  Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping.

Authors:  S G Kim
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

3.  Use of 3D DCE-MRI for the estimation of renal perfusion and glomerular filtration rate: an intrasubject comparison of FLASH and KWIC with a comprehensive framework for evaluation.

Authors:  Eli Eikefjord; Erling Andersen; Erlend Hodneland; Frank Zöllner; Arvid Lundervold; Einar Svarstad; Jarle Rørvik
Journal:  AJR Am J Roentgenol       Date:  2015-03       Impact factor: 3.959

4.  Functional multiparametric magnetic resonance imaging of the kidneys using blood oxygen level dependent and diffusion-weighted sequences.

Authors:  Gianluca Giannarini; Thomas M Kessler; Beat Roth; Peter Vermathen; Harriet C Thoeny
Journal:  J Urol       Date:  2014-02-25       Impact factor: 7.450

5.  Measurement of renal tissue oxygenation with blood oxygen level-dependent MRI and oxygen transit modeling.

Authors:  Jeff L Zhang; Glen Morrell; Henry Rusinek; Lizette Warner; Pierre-Hugues Vivier; Alfred K Cheung; Lilach O Lerman; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2014-01-22

Review 6.  MRI tools for assessment of microstructure and nephron function of the kidney.

Authors:  Luke Xie; Kevin M Bennett; Chunlei Liu; G Allan Johnson; Jeff Lei Zhang; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2016-09-14

7.  Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.

Authors:  D Le Bihan; E Breton; D Lallemand; M L Aubin; J Vignaud; M Laval-Jeantet
Journal:  Radiology       Date:  1988-08       Impact factor: 11.105

8.  Dynamic MR urography in children with uropathic disease with a combined 2D and 3D acquisition protocol--comparison with MAG3 scintigraphy.

Authors:  A Boss; P Martirosian; J Fuchs; F Obermayer; I Tsiflikas; F Schick; J F Schäfer
Journal:  Br J Radiol       Date:  2014-10-01       Impact factor: 3.039

9.  Assessment of renal artery stenosis using intravoxel incoherent motion diffusion-weighted magnetic resonance imaging analysis.

Authors:  Behzad Ebrahimi; Naveen Rihal; John R Woollard; James D Krier; Alfonso Eirin; Lilach O Lerman
Journal:  Invest Radiol       Date:  2014-10       Impact factor: 6.016

10.  MRI-measurement of perfusion and glomerular filtration in the human kidney with a separable compartment model.

Authors:  Steven P Sourbron; Henrik J Michaely; Maximilian F Reiser; Stefan O Schoenberg
Journal:  Invest Radiol       Date:  2008-01       Impact factor: 6.016

View more
  1 in total

1.  Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.

Authors:  Cesar A Romero; Glauber Cabral; Robert A Knight; Guangliang Ding; Edward L Peterson; Oscar A Carretero
Journal:  Am J Physiol Renal Physiol       Date:  2017-10-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.