Literature DB >> 17213464

Renal function measurements from MR renography and a simplified multicompartmental model.

Vivian S Lee1, Henry Rusinek, Louisa Bokacheva, Ambrose J Huang, Niels Oesingmann, Qun Chen, Manmeen Kaur, Keyma Prince, Ting Song, Elissa L Kramer, Edward F Leonard.   

Abstract

The purpose of this study was to determine the accuracy and sources of error in estimating single-kidney glomerular filtration rate (GFR) derived from low-dose gadolinium-enhanced T1-weighted MR renography. To analyze imaging data, MR signal intensity curves were converted to concentration vs. time curves, and a three-compartment, six-parameter model of the vascular-nephron system was used to analyze measured aortic, cortical, and medullary enhancement curves. Reliability of the parameter estimates was evaluated by sensitivity analysis and by Monte Carlo analyses of model solutions to which random noise had been added. The dominant sensitivity of the medullary enhancement curve to GFR 1-4 min after tracer injection was supported by a low coefficient of variation in model-fit GFR values (4%) when measured data were subjected to 5% noise. These analyses also showed the minimal effects of bolus dispersion in the aorta on parameter reliability. Single-kidney GFR from MR renography analyzed by the three-compartment model (4.0-71.4 ml/min) agreed well with reference measurements from (99m)Tc-DTPA clearance and scintigraphy (r = 0.84, P < 0.001). Bland-Altman analysis showed an average difference of 11.9 ml/min (95% confidence interval = 5.8-17.9 ml/min) between model and reference values. We conclude that a nephron-based multicompartmental model can be used to derive clinically useful estimates of single-kidney GFR from low-dose MR renography.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17213464     DOI: 10.1152/ajprenal.00347.2006

Source DB:  PubMed          Journal:  Am J Physiol Renal Physiol        ISSN: 1522-1466


  41 in total

1.  Joint segmentation and groupwise registration of cardiac perfusion images using temporal information.

Authors:  Dwarikanath Mahapatra
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

Review 2.  [Functional magnetic resonance imaging of the kidneys].

Authors:  R S Lanzman; M Notohamiprodjo; H J Wittsack
Journal:  Radiologe       Date:  2015-12       Impact factor: 0.635

Review 3.  GFR Estimating Equations and Liver Disease.

Authors:  Tomasz Beben; Dena E Rifkin
Journal:  Adv Chronic Kidney Dis       Date:  2015-09       Impact factor: 3.620

4.  Functional assessment of the kidney from magnetic resonance and computed tomography renography: impulse retention approach to a multicompartment model.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Lilach O Lerman; Qun Chen; Chekema Prince; Niels Oesingmann; Ting Song; Vivian S Lee
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

5.  Angiotensin-converting enzyme inhibitor-enhanced MR renography: repeated measures of GFR and RPF in hypertensive patients.

Authors:  Jeff L Zhang; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Qun Chen; Pippa Storey; Keyma Prince; Elizabeth M Hecht; Danny C Kim; Vivian S Lee
Journal:  Am J Physiol Renal Physiol       Date:  2009-01-21

Review 6.  Renal relevant radiology: renal functional magnetic resonance imaging.

Authors:  Behzad Ebrahimi; Stephen C Textor; Lilach O Lerman
Journal:  Clin J Am Soc Nephrol       Date:  2013-12-26       Impact factor: 8.237

7.  Prospective pediatric study comparing glomerular filtration rate estimates based on motion-robust dynamic contrast-enhanced magnetic resonance imaging and serum creatinine (eGFR) to 99mTc DTPA.

Authors:  Sila Kurugol; Onur Afacan; Richard S Lee; Catherine M Seager; Michael A Ferguson; Deborah R Stein; Reid C Nichols; Monet Dugan; Alto Stemmer; Simon K Warfield; Jeanne S Chow
Journal:  Pediatr Radiol       Date:  2020-01-27

8.  Performance of an efficient image-registration algorithm in processing MR renography data.

Authors:  Christopher C Conlin; Jeff L Zhang; Florian Rousset; Clement Vachet; Yangyang Zhao; Kathryn A Morton; Kristi Carlston; Guido Gerig; Vivian S Lee
Journal:  J Magn Reson Imaging       Date:  2015-07-14       Impact factor: 4.813

9.  Optimal k-space sampling for dynamic contrast-enhanced MRI with an application to MR renography.

Authors:  Ting Song; Andrew F Laine; Qun Chen; Henry Rusinek; Louisa Bokacheva; Ruth P Lim; Gerhard Laub; Randall Kroeker; Vivian S Lee
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

10.  Acute impairment of rat renal function by L -NAME as measured using dynamic MRI.

Authors:  Farid Sari-Sarraf; Silvia Pomposiello; Didier Laurent
Journal:  MAGMA       Date:  2008-07-26       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.