Literature DB >> 26835065

THERMOCOOL® SMARTTOUCH® CATHETER - The Evidence So Far for Contact Force Technology and the Role of VISITAG™ MODULE.

Tina Lin1, Feifan Ouyang2, Karl-Heinz Kuck3, Roland Tilz4.   

Abstract

Catheter ablation has become an important modality in the treatment of most cardiac arrhythmias. In recent years there has been significant development of new ablation energies and technologies in an attempt to improve clinical outcomes and decrease disease burden. Ablation failure is often associated with inadequate lesion formation, and catheter-to-myocardial contact force (CF) and catheter stability are two of the parameters required to produce effective lesions during radiofrequency energy application. Recently, CF sensing catheters and tagging modules have been developed to give operators realtime data on catheter force and stability. This review describes the novel THERMOCOOL(®) SMARTTOUCH(®) CATHETER (Biosense Webster Inc., CA, US) and VISITAG™ MODULE (Biosense Webster Inc., CA, US) software, and discusses the results of several studies on CF and catheter stability during mapping and ablation of the left atrium and ventricle from our electrophysiology laboratory. We assess the short- and longer-term outcomes during mapping and ablation with and without CF data, as well as the use of the VISITAG MODULE™ software, which allows the evaluation of multiple parameters of lesion formation, then integrates and displays this as automatic tags in a relatively objective way.

Entities:  

Keywords:  Radiofrequency ablation; THERMOCOOL® SMARTTOUCH® CATHETER; VISITAG™; contact force; three-dimensional (3D) mapping

Year:  2014        PMID: 26835065      PMCID: PMC4712621          DOI: 10.15420/aer.2011.3.1.44

Source DB:  PubMed          Journal:  Arrhythm Electrophysiol Rev        ISSN: 2050-3369


  35 in total

1.  Area under the real-time contact force curve (force-time integral) predicts radiofrequency lesion size in an in vitro contractile model.

Authors:  Dipen C Shah; Hendrik Lambert; Hiroshi Nakagawa; Arne Langenkamp; Nicolas Aeby; Giovanni Leo
Journal:  J Cardiovasc Electrophysiol       Date:  2010-09

2.  Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters.

Authors:  Tobias Reichlin; Sven Knecht; Christopher Lane; Michael Kühne; Eyal Nof; Nagesh Chopra; Thomas M Tadros; Vivek Y Reddy; Beat Schaer; Roy M John; Stefan Osswald; William G Stevenson; Christian Sticherling; Gregory F Michaud
Journal:  Heart Rhythm       Date:  2013-10-28       Impact factor: 6.343

3.  Contact force monitoring for cardiac mapping in patients with ventricular tachycardia.

Authors:  Hiroya Mizuno; Pasquale Vergara; Giuseppe Maccabelli; Nicola Trevisi; Sebastiano Colombo Eng; Chiara Brombin; Patrizio Mazzone; Paolo Della Bella
Journal:  J Cardiovasc Electrophysiol       Date:  2013-02-01

4.  Ipsilateral pulmonary vein isolation performed by a single continuous circular lesion: role of pulmonary vein mapping during ablation.

Authors:  Alexander Fürnkranz; Julian K R Chun Julian; Boris Schmidt; Peter Wohlmuth; Roland Tilz; Karl-Heinz Kuck; Feifan Ouyang
Journal:  Europace       Date:  2011-03-31       Impact factor: 5.214

5.  Recovered pulmonary vein conduction as a dominant factor for recurrent atrial tachyarrhythmias after complete circular isolation of the pulmonary veins: lessons from double Lasso technique.

Authors:  Feifan Ouyang; Matthias Antz; Sabine Ernst; Hitoshi Hachiya; Hercules Mavrakis; Florian T Deger; Anselm Schaumann; Julian Chun; Peter Falk; Detlef Hennig; Xingpeng Liu; Dietmar Bänsch; Karl-Heinz Kuck
Journal:  Circulation       Date:  2004-12-27       Impact factor: 29.690

6.  Pulmonary vein isolation with high-intensity focused ultrasound: results from the HIFU 12F study.

Authors:  Boris Schmidt; Kyoung Ryul Julian Chun; Andreas Metzner; Alexander Fuernkranz; Feifan Ouyang; Karl-Heinz Kuck
Journal:  Europace       Date:  2009-08-04       Impact factor: 5.214

7.  Acute termination of human atrial fibrillation by identification and catheter ablation of localized rotors and sources: first multicenter experience of focal impulse and rotor modulation (FIRM) ablation.

Authors:  Kalyanam Shivkumar; Kenneth A Ellenbogen; John D Hummel; John M Miller; Jonathan S Steinberg
Journal:  J Cardiovasc Electrophysiol       Date:  2012-11-06

8.  Study design of the man and machine trial: a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation.

Authors:  Andreas Rillig; Boris Schmidt; Daniel Steven; Udo Meyerfeldt; Luigi DI Biase; Erik Wissner; Rüdiger Becker; Dierk Thomas; Peter Wohlmuth; G Joseph Gallinghouse; Eberhardt Scholz; Werner Jung; Stefan Willems; Andrea Natale; Feifan Ouyang; Karl Heinz Kuck; Roland Tilz
Journal:  J Cardiovasc Electrophysiol       Date:  2012-11-06

9.  Elimination of local abnormal ventricular activities: a new end point for substrate modification in patients with scar-related ventricular tachycardia.

Authors:  Pierre Jaïs; Philippe Maury; Paul Khairy; Frédéric Sacher; Isabelle Nault; Yuki Komatsu; Mélèze Hocini; Andrei Forclaz; Amir S Jadidi; Rukshen Weerasooryia; Ashok Shah; Nicolas Derval; Hubert Cochet; Sebastien Knecht; Shinsuke Miyazaki; Nick Linton; Lena Rivard; Matthew Wright; Stephen B Wilton; Daniel Scherr; Patrizio Pascale; Laurent Roten; Michala Pederson; Pierre Bordachar; François Laurent; Steven J Kim; Philippe Ritter; Jacques Clementy; Michel Haïssaguerre
Journal:  Circulation       Date:  2012-04-04       Impact factor: 29.690

10.  The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study.

Authors:  Kyoung-Ryul Julian Chun; Boris Schmidt; Andreas Metzner; Roland Tilz; Thomas Zerm; Ilka Köster; Alexander Fürnkranz; Buelent Koektuerk; Melanie Konstantinidou; Matthias Antz; Feifan Ouyang; Karl Heinz Kuck
Journal:  Eur Heart J       Date:  2008-12-24       Impact factor: 29.983

View more
  7 in total

Review 1.  3D Mapping for PVI- Geometry, Image Integration and Incorporation of Contact Force Into Work Flow.

Authors:  Martin Borlich; Leon Iden; Krister Kuhnhardt; Ingo Paetsch; Gerhard Hindricks; Philipp Sommer
Journal:  J Atr Fibrillation       Date:  2018-04-30

Review 2.  The Impact of Advances in Atrial Fibrillation Ablation Devices on the Incidence and Prevention of Complications.

Authors:  Fehmi Keçe; Katja Zeppenfeld; Serge A Trines
Journal:  Arrhythm Electrophysiol Rev       Date:  2018-08

3.  Lesion modeling, characterization, and visualization for image-guided cardiac ablation therapy monitoring.

Authors:  Cristian A Linte; Jon J Camp; Maryam E Rettmann; Dieter Haemmerich; Mehmet K Aktas; David T Huang; Douglas L Packer; David R Holmes
Journal:  J Med Imaging (Bellingham)       Date:  2018-03-01

4.  Contact force-sensing catheters: performance in an ex vivo porcine heart model.

Authors:  Eduardo Franco; Daniel Rodríguez Muñoz; Roberto Matía; Antonio Hernández-Madrid; Inmaculada Sánchez Pérez; José Luis Zamorano; Javier Moreno
Journal:  J Interv Card Electrophysiol       Date:  2018-08-14       Impact factor: 1.900

5.  Catheter inversion during cavotricuspid isthmus catheter ablation: The new shaft visualization catheter reduces fluoroscopy use.

Authors:  Amato Santoro; Claudia Baiocchi; Nicolò Sisti; Valerio Zacà; Carlo Renato Pondrelli; Francesca Falciani; Filippo Lamberti
Journal:  J Arrhythm       Date:  2021-07-11

6.  Two-Year Follow-Up after Contact Force Sensing Radiofrequency Catheter and Second-Generation Cryoballoon Ablation for Paroxysmal Atrial Fibrillation: A Comparative Single Centre Study.

Authors:  Attila Kardos; Zsuzsanna Kis; Zoltan Som; Zsofia Nagy; Csaba Foldesi
Journal:  Biomed Res Int       Date:  2016-05-22       Impact factor: 3.411

7.  Comparison of the efficacy between impedance-guided and contact force-guided atrial fibrillation ablation using an automated annotation system.

Authors:  Hyoung-Seob Park; In-Cheol Kim; Yun-Kyeong Cho; Hyuck-Jun Yoon; Hyungseop Kim; Chang-Wook Nam; Seongwook Han; Seung-Ho Hur; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  J Arrhythm       Date:  2018-04-11
  7 in total