Literature DB >> 19654125

Pulmonary vein isolation with high-intensity focused ultrasound: results from the HIFU 12F study.

Boris Schmidt1, Kyoung Ryul Julian Chun, Andreas Metzner, Alexander Fuernkranz, Feifan Ouyang, Karl-Heinz Kuck.   

Abstract

AIMS: High-intensity focused ultrasound (HIFU) applied via a balloon catheter (BC) is a novel technology for simplified pulmonary vein isolation (PVI). Safety and efficacy of the third generation HIFU-BC were assessed. METHODS AND
RESULTS: In 22 patients (10 male, mean age 65 +/- 6 years) with paroxysmal atrial fibrillation (PAF), a PVI during real-time PV spike registration and oesophageal temperature measurement was attempted. In 15 patients, a steerable sheath was used along with the HIFU-BC. In 67 of 83 PVs (81%), PVI was achieved exclusively using HIFU. Using the steerable sheath, the acute PVI rate rose from 50% (10/20 PVs) to 90% (57/63 PVs). In the latter, PVI was achieved with a single HIFU application in 60% (38/63 PVs) and mean sonication time of 11 +/- 7 s. The mean procedure time was 166 +/- 74 min including 58 +/- 25 min of HIFU-BC left atrial indwelling time. In four patients, peri-procedural complications occurred (one transient ischaemic attack, one phrenic nerve palsy, and two vascular access complications). During a median follow-up of 342 days (range 272-378 days), 71% patients remained free of any AF/AT recurrence without antiarrhythmic drugs after a single procedure.
CONCLUSION: The novel defocused 12F HIFU-BC used in conjunction with a steerable sheath allows for very rapid PVI in patients with PAF. The enthusiasm for rapid PVI is still dampened by the potential risk of collateral damage.

Entities:  

Mesh:

Year:  2009        PMID: 19654125     DOI: 10.1093/europace/eup208

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  8 in total

1.  THERMOCOOL® SMARTTOUCH® CATHETER - The Evidence So Far for Contact Force Technology and the Role of VISITAG™ MODULE.

Authors:  Tina Lin; Feifan Ouyang; Karl-Heinz Kuck; Roland Tilz
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-05-30

Review 2.  Therapeutic endoscopy for acute upper gastrointestinal bleeding.

Authors:  Mitchell S Cappell
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2010-03-09       Impact factor: 46.802

Review 3.  Emerging non-cancer applications of therapeutic ultrasound.

Authors:  Meaghan A O'Reilly; Kullervo Hynynen
Journal:  Int J Hyperthermia       Date:  2015-03-20       Impact factor: 3.914

4.  Pulmonary vein electrophysiology during cryoballoon ablation as a predictor for procedural success.

Authors:  Uwe Dorwarth; Martin Schmidt; Michael Wankerl; Juergen Krieg; Florian Straube; Ellen Hoffmann
Journal:  J Interv Card Electrophysiol       Date:  2011-05-19       Impact factor: 1.900

Review 5.  Innovations in atrial fibrillation ablation.

Authors:  Jitae A Kim; Khurrum Khan; Riyad Kherallah; Shamis Khan; Ishan Kamat; Owais Ulhaq; Qussay Marashly; Mihail G Chelu
Journal:  J Interv Card Electrophysiol       Date:  2022-04-11       Impact factor: 1.900

Review 6.  Cardiovascular applications of therapeutic ultrasound.

Authors:  Babak Nazer; Edward P Gerstenfeld; Akiko Hata; Lawrence A Crum; Thomas J Matula
Journal:  J Interv Card Electrophysiol       Date:  2013-12-03       Impact factor: 1.900

Review 7.  Surgical perspectives in the management of atrial fibrillation.

Authors:  Katerina Kyprianou; Agamemnon Pericleous; Antonio Stavrou; Inetzi A Dimitrakaki; Dimitrios Challoumas; Georgios Dimitrakakis
Journal:  World J Cardiol       Date:  2016-01-26

8.  The Future of Pulmonary Vein Isolation - Single-shot Devices, Remote Navigation or Improving Conventional Radiofrequency Delivery by Contact Monitoring and Lesion Characterisation?

Authors:  David Filgueiras-Rama; Jose L Merino
Journal:  Arrhythm Electrophysiol Rev       Date:  2013-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.