Literature DB >> 23131063

Study design of the man and machine trial: a prospective international controlled noninferiority trial comparing manual with robotic catheter ablation for treatment of atrial fibrillation.

Andreas Rillig1, Boris Schmidt, Daniel Steven, Udo Meyerfeldt, Luigi DI Biase, Erik Wissner, Rüdiger Becker, Dierk Thomas, Peter Wohlmuth, G Joseph Gallinghouse, Eberhardt Scholz, Werner Jung, Stefan Willems, Andrea Natale, Feifan Ouyang, Karl Heinz Kuck, Roland Tilz.   

Abstract

BACKGROUND: Pulmonary vein isolation (PVI) has become the cornerstone procedure for the treatment of symptomatic drug-resistant atrial fibrillation (AF). At the present time, circumferential PVI (CPVI) using irrigated radiofrequency (RF) is the mostly used ablation technique. However, for CPVI, precise catheter navigation and excellent catheter stability is crucial thereby requiring experienced operators. Robotic navigation systems have been introduced to facilitate catheter navigation and to improve catheter stability, therefore potentially increasing procedural success and making CPVI accessible to less experienced operators. To date, no prospective randomized trial has evaluated the efficacy and safety of CPVI using RNS compared to manually performed ablation.
METHODS: In this prospective international multicenter noninferiority trial, 258 patients with either paroxysmal or short-standing persistent AF will be randomized for comparison of PVI using either manual or robotic ablation. In all patients, CPVI will be performed using irrigated RF ablation in combination with a 3D mapping system. The primary endpoint of the trial is the absence of AF or atrial tachycardia without antiarrhythmic drug therapy during 12-month follow-up. Secondary endpoints will be evaluation of periprocedural complications and procedural data such as procedure time, fluoroscopy time, as well as the incidence of esophageal injury assessed by endoscopy within 48 hours after the procedure.
CONCLUSION: The "Man and Machine Trial" is the first prospective international randomized controlled multicenter noninferiority trial to compare manually performed CPVI with robotically navigated CPVI, evaluating both the safety and efficacy of the 2 techniques during a 12-month follow-up period.
© 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 23131063     DOI: 10.1111/j.1540-8167.2012.02418.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  7 in total

1.  THERMOCOOL® SMARTTOUCH® CATHETER - The Evidence So Far for Contact Force Technology and the Role of VISITAG™ MODULE.

Authors:  Tina Lin; Feifan Ouyang; Karl-Heinz Kuck; Roland Tilz
Journal:  Arrhythm Electrophysiol Rev       Date:  2014-05-30

Review 2.  Comparing Antiarrhythmic Drugs and Catheter Ablation for Treatment of Atrial Fibrillation.

Authors:  Andreas Rillig; Tina Lin; Feifan Ouyang; Karl Heinz Kuck; Roland Richard Tilz
Journal:  J Atr Fibrillation       Date:  2013-06-30

Review 3.  Differences In Tissue Injury and Ablation Outcomes In Atrial Fibrillation Patients - Manual versus Robotic Catheters.

Authors:  Georg Nölker; Dieter Horstkotte; Klaus Jürgen Gutleben
Journal:  J Atr Fibrillation       Date:  2013-08-31

4.  Experience matters: long-term results of pulmonary vein isolation using a robotic navigation system for the treatment of paroxysmal atrial fibrillation.

Authors:  Andreas Rillig; Tina Lin; Boris Schmidt; Britta Feige; Christian Heeger; Jascha Wegner; Erik Wissner; Andreas Metzner; Anita Arya; Shibu Mathew; Peter Wohlmuth; Feifan Ouyang; Karl-Heinz Kuck; Roland Richard Tilz
Journal:  Clin Res Cardiol       Date:  2015-07-22       Impact factor: 5.460

5.  [Catheter ablation of paroxysmal atrial fibrillation. Optimal approach and result].

Authors:  Shibu Mathew; Andreas Metzner; Feifan Ouyang; Karl-Heinz Kuck; Roland Richard Tilz
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-04-16

6.  The comparison between robotic and manual ablations in the treatment of atrial fibrillation: a systematic review and meta-analysis.

Authors:  Wenli Zhang; Nan Jia; Jinzi Su; Jinxiu Lin; Feng Peng; Wenquan Niu
Journal:  PLoS One       Date:  2014-05-06       Impact factor: 3.240

Review 7.  Robotic magnetic navigation for ablation of human arrhythmias.

Authors:  Antoine Da Costa; Jean Baptiste Guichard; Cécile Roméyer-Bouchard; Antoine Gerbay; Karl Isaaz
Journal:  Med Devices (Auckl)       Date:  2016-09-19
  7 in total