Literature DB >> 26816576

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

Ye-Kyu Rhee1, Yoon-Hyuk Huh1, Lee-Ra Cho1, Chan-Jin Park1.   

Abstract

PURPOSE: The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression.
MATERIALS AND METHODS: Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis.
RESULTS: In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression.
CONCLUSION: The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

Entities:  

Keywords:  Intraoral scanning; Laser scanning; Three-dimensional deviation; Two-dimensional deviation

Year:  2015        PMID: 26816576      PMCID: PMC4722150          DOI: 10.4047/jap.2015.7.6.460

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  32 in total

1.  The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions.

Authors:  Jeffrey A Ceyhan; Glen H Johnson; Xavier Lepe
Journal:  J Prosthet Dent       Date:  2003-08       Impact factor: 3.426

2.  Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling.

Authors:  Andreas Syrek; Gunnar Reich; Dieter Ranftl; Christoph Klein; Barbara Cerny; Jutta Brodesser
Journal:  J Dent       Date:  2010-04-08       Impact factor: 4.379

3.  A clinical study comparing marginal and occlusal accuracy of crowns fabricated from double-arch and complete-arch impressions.

Authors:  J R Cox
Journal:  Aust Dent J       Date:  2005-06       Impact factor: 2.291

4.  Will digital impressions eliminate the current problems with conventional impressions?

Authors:  Gordon J Christensen
Journal:  J Am Dent Assoc       Date:  2008-06       Impact factor: 3.634

5.  Trouble-shooting dual arch impressions II.

Authors:  G J Kaplowitz
Journal:  J Am Dent Assoc       Date:  1997-09       Impact factor: 3.634

6.  Comparison of occlusal contacts in maximum intercuspation for two impression techniques.

Authors:  M H Parker; S M Cameron; J C Hughbanks; D E Reid
Journal:  J Prosthet Dent       Date:  1997-09       Impact factor: 3.426

7.  Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth.

Authors:  Beatriz Giménez; Mutlu Özcan; Francisco Martínez-Rus; Guillermo Pradíes
Journal:  Int J Oral Maxillofac Implants       Date:  2014 Jul-Aug       Impact factor: 2.804

8.  Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis.

Authors:  Robert G Nedelcu; Anna S K Persson
Journal:  J Prosthet Dent       Date:  2014-08-16       Impact factor: 3.426

Review 9.  The accuracy of implant impressions: a systematic review.

Authors:  Heeje Lee; Joseph S So; J L Hochstedler; Carlo Ercoli
Journal:  J Prosthet Dent       Date:  2008-10       Impact factor: 3.426

10.  Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays.

Authors:  Glen H Johnson; Lloyd A Mancl; E Ricardo Schwedhelm; Douglas R Verhoef; Xavier Lepe
Journal:  J Prosthet Dent       Date:  2010-01       Impact factor: 3.426

View more
  17 in total

1.  Assessment of different types of intra oral scanners and 3D printers on the accuracy of printed models: An in vitro study.

Authors:  Fernando Igai; Washington-Steagall Junior; Carolina-Mayumi Iegami; Pedro-Tortamano Neto
Journal:  J Clin Exp Dent       Date:  2021-12-01

Review 2.  Intraoral Scanner Technologies: A Review to Make a Successful Impression.

Authors:  Raphaël Richert; Alexis Goujat; Laurent Venet; Gilbert Viguie; Stéphane Viennot; Philip Robinson; Jean-Christophe Farges; Michel Fages; Maxime Ducret
Journal:  J Healthc Eng       Date:  2017-09-05       Impact factor: 2.682

3.  Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis.

Authors:  Hang-Nga Mai; Kyeong Eun Lee; Kyu-Bok Lee; Seung-Mi Jeong; Seok-Jae Lee; Cheong-Hee Lee; Seo-Young An; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

Review 4.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

5.  Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol.

Authors:  Corina Marilena Cristache; Silviu Gurbanescu
Journal:  Int J Dent       Date:  2017-05-07

6.  In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques.

Authors:  Emi Kamimura; Shinpei Tanaka; Masayuki Takaba; Keita Tachi; Kazuyoshi Baba
Journal:  PLoS One       Date:  2017-06-21       Impact factor: 3.240

7.  Efficient digitalization method for dental restorations using micro-CT data.

Authors:  Changhwan Kim; Seung Hoon Baek; Taewon Lee; Jonggun Go; Sun Young Kim; Seungryong Cho
Journal:  Sci Rep       Date:  2017-03-15       Impact factor: 4.379

8.  A comparative evaluation of intraoral and extraoral digital impressions: An in vivo study.

Authors:  Gursharan Kaur Sason; Gaurang Mistry; Rubina Tabassum; Omkar Shetty
Journal:  J Indian Prosthodont Soc       Date:  2018 Apr-Jun

9.  Accuracy evaluation of dental models manufactured by CAD/CAM milling method and 3D printing method.

Authors:  Yoo-Geum Jeong; Wan-Sun Lee; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

10.  Accuracy of new implant impression technique using dual arch tray and bite impression coping.

Authors:  Shin-Eon Lee; Sung-Eun Yang; Cheol-Won Lee; Won-Sup Lee; Su Young Lee
Journal:  J Adv Prosthodont       Date:  2018-08-17       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.