Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling.

Andreas Syrek1, Gunnar Reich, Dieter Ranftl, Christoph Klein, Barbara Cerny, Jutta Brodesser.   

Abstract

OBJECTIVES: The aim of the present study was to compare the fit of all-ceramic crowns fabricated from intraoral digital impressions with the fit of all-ceramic crowns fabricated from silicone impressions.
METHODS: Twenty patients agreed to take part in the study to receive two Lava crowns each for the same preparation. One crown was fabricated from intraoral scans using the Lava Chairside Oral Scanner (Lava C.O.S.), and the other crown from a two-step silicone impression. Prior to cementation the fit of both crowns was clinically evaluated by two calibrated and blinded examiners; the marginal fit was also scored from replicas. Data from the replica scores were analysed by Anderson-Darling test, Levene's test and Mann-Whitney test. All tests were performed with alpha-level of 0.05.
RESULTS: Median marginal gap in the conventional impression group was 71microm (Q1:45microm; Q3:98microm), and in the digital impression group 49microm (Q1:32microm; Q3:65microm). Mann-Whitney test revealed a significant difference between the groups (p<0.05). No differences were found regarding the occlusion, and there was a trend for better interproximal fit for the digitally fabricated crowns.
CONCLUSIONS: 1. Crowns from intraoral scans revealed significantly better marginal fit than crowns from silicone impressions. 2. Marginal discrepancies in both groups were within the limits of clinical acceptability. 3. Crowns from intraoral scans tended to show better interproximal contact area quality. 4. Crowns from both groups performed equally well with regard to occlusion. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20381576     DOI: 10.1016/j.jdent.2010.03.015

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  62 in total

1.  Clinical evaluation comparing the fit of all-ceramic crowns obtained from silicone and digital intraoral impressions.

Authors:  Cristina Zarauz; Arelhys Valverde; Francisco Martinez-Rus; Bassam Hassan; Guillermo Pradies
Journal:  Clin Oral Investig       Date:  2015-09-12       Impact factor: 3.573

2.  In vivo precision of conventional and digital methods for obtaining quadrant dental impressions.

Authors:  Andreas Ender; Moritz Zimmermann; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-11-07       Impact factor: 3.573

3.  Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns.

Authors:  S Berrendero; M P Salido; A Valverde; A Ferreiroa; G Pradíes
Journal:  Clin Oral Investig       Date:  2016-01-23       Impact factor: 3.573

4.  The comparative evaluation of the translucency of crowns fabricated with three different all-ceramic materials: an in vitro study.

Authors:  Y Sravanthi; Y V Ramani; Asha M Rathod; Sabita M Ram; Hetal Turakhia
Journal:  J Clin Diagn Res       Date:  2015-02-01

5.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

Review 6.  Revolutionizing restorative dentistry: an overview.

Authors:  D R Prithviraj; Harleen Kaur Bhalla; Richa Vashisht; K Sounderraj; Shruthi Prithvi
Journal:  J Indian Prosthodont Soc       Date:  2014-02-05

7.  In vitro evaluation of prosthodontic impression on natural dentition: a comparison between traditional and digital techniques.

Authors:  G Malaguti; R Rossi; B Marziali; A Esposito; G Bruno; C Dariol; A DI Fiore
Journal:  Oral Implantol (Rome)       Date:  2017-02-14

8.  Accuracy of digital and conventional impression techniques and workflow.

Authors:  Paul Seelbach; Cora Brueckel; Bernd Wöstmann
Journal:  Clin Oral Investig       Date:  2012-10-21       Impact factor: 3.573

9.  The clinical accuracy of single crowns exclusively fabricated by digital workflow--the comparison of two systems.

Authors:  Petya K Brawek; Stefan Wolfart; Lutz Endres; Armin Kirsten; Sven Reich
Journal:  Clin Oral Investig       Date:  2013-01-31       Impact factor: 3.573

10.  Accuracy of digital models obtained by direct and indirect data capturing.

Authors:  Jan-Frederik Güth; Christine Keul; Michael Stimmelmayr; Florian Beuer; Daniel Edelhoff
Journal:  Clin Oral Investig       Date:  2012-07-31       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.