Literature DB >> 16050087

A clinical study comparing marginal and occlusal accuracy of crowns fabricated from double-arch and complete-arch impressions.

J R Cox1.   

Abstract

BACKGROUND: The double-arch impression technique is widely used in the provision of laboratory fabricated restorations. However, there is little clinical evidence to support or refute its use. The aim of this prospective clinical study was to evaluate the occlusion and marginal fit of posterior full crowns made from double-arch impressions, and to compare these to control crowns fabricated from conventional complete-arch impressions.
METHODS: Ten patients requiring single posterior ceramo-metal full crowns had both double-arch and complete-arch impressions taken of the prepared tooth. Two crowns were fabricated for each tooth, using the casts made from both impression methods. Both crowns were tried in and the occlusion and margins evaluated. The results were composed using nonparametric statistical analysis with the probability level for significance at alpha=0.05.
RESULTS: The crowns fabricated from the double-arch impression were found to be more accurate in closure to the intercuspal position and had fewer interferences in lateral excursions. There were no significant differences between the two crown groups regarding protrusive interferences and margin quality.
CONCLUSIONS: Crowns fabricated from the double-arch impressions were equivalent in marginal accuracy and superior occlusally to crowns fabricated from the complete-arch impressions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16050087     DOI: 10.1111/j.1834-7819.2005.tb00346.x

Source DB:  PubMed          Journal:  Aust Dent J        ISSN: 0045-0421            Impact factor:   2.291


  5 in total

1.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

2.  In vivo Study of the Accuracy of Dual-arch Impressions.

Authors:  Luciana Martinelli Santayana de Lima; Gilberto Antonio Borges; Luiz Henrique Burnett Junior; Ana Maria Spohr
Journal:  J Int Oral Health       Date:  2014-06-26

3.  Influence of Custom Trays, Dual-Arch Passive, Flexed Trays and Viscosities of Elastomeric Impression Materials on Working Dies.

Authors:  Mansi Arora; Shivani Kohli; Rupali Kalsi
Journal:  J Clin Diagn Res       Date:  2016-05-01

4.  A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study.

Authors:  Poonam R Kulkarni; Rahul S Kulkarni; Rupal J Shah; Rahul Chhajlani; Bhuwan Saklecha; Kavita Maru
Journal:  J Clin Diagn Res       Date:  2017-04-01

5.  Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

Authors:  Ye-Kyu Rhee; Yoon-Hyuk Huh; Lee-Ra Cho; Chan-Jin Park
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.