Literature DB >> 12886207

The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions.

Jeffrey A Ceyhan1, Glen H Johnson, Xavier Lepe.   

Abstract

STATEMENT OF PROBLEM: Dual-arch trays are often used to generate impressions of prepared teeth and of the opposing arch simultaneously. There is concern that accuracy of the casts generated with this technique can be affected by the type of tray, viscosity of the impression material, and sequence of pouring the cast.
PURPOSE: This study compared the accuracy of working dies made from impressions with metal and plastic dual-arch trays, for 2 different viscosities of impression tray material and by altering which side of the impression was poured first.
MATERIALS AND METHODS: Impressions were made of a typodont mandibular arch containing a circular stainless steel crown preparation (standard). There were 3 variables: type of dual-arch tray, impression material viscosity, and order of pour of the impressioned arches. A balanced design with independent samples was used (n=10). Two types of dual-arch trays, plastic (Triple Tray) and metal (COE Impression Tray), and 2 viscosities of addition silicone for the tray were used (Aquasil Rigid and Aquasil Monophase). Type IV gypsum (Fuji-Rock) with a ratio of 20 mL of distilled water to 100 g of powder was hand-mixed for 10 seconds then mixed under vacuum for 40 seconds and poured into the trays while being vibrated. One side of the dual-arch impression was poured with 35 g of stone and allowed to set for 1 hour before the other side was poured with 35 g of stone. The order of pour was randomized, and all casts were allowed to set for 24 hours at room temperature before removal. The dies were measured in 3 dimensions (buccolingual, mesiodistal, and occlusogingival) with a measuring microscope. The gypsum working dies were placed into a custom jig fabricated to permit measurement at a fixed, reproducible position under the microscope. Each dimension of the working dies was measured 3 times, and the mean was used for the sample value. The same 3 aspects of the stainless steel standard were measured multiple times, before and then at the conclusion of measuring all working dies, to arrive at the 3 standard values to which all working die means were compared. The means for the standard used in the statistical analysis were those taken at the conclusion of the study. The intraexaminer variation for measuring the standard was 0.001 mm. A 3-factor analysis of variance was used for the statistical analysis with hypothesis testing at alpha=.05.
RESULTS: Statistically significant differences were found with viscosity selection for the buccolingual and occlusogingival dimensions of the working die. The rigid material produced working dies slightly taller (1 microm) than the standard, and those from the monophase material were 4 microm shorter. Regarding tray selection, metal trays were slightly more accurate in the mesiodistal dimension, and when monophase was used in a plastic tray, gypsum dies were nearly 30 microm smaller in the mesiodistal dimension (P<.05). Differences were not detected for sequence of pouring impressions.
CONCLUSION: Within the limitations of this study, the monophase material, when compared with the rigid impression material, was most accurate for the occlusogingival and mesiodistal dimensions, although not as accurate in the buccolingual. This buccolingual difference (0.002 mm-0.006 mm) would be clinically inconsequential with the application of die spacer. The rigid impression material was also unaffected by tray selection for the mesiodistal, whereas monophase was affected. When a monophase impression material was used, plastic dual-arch trays yielded gypsum dies which were significantly smaller (0.029 mm) than the ones generated from the metal trays (0.006 mm). Thus rigid impression materials can be recommended for use in dual-arch trays; however, the magnitude of the differences would generally not be clinically significant because they could be compensated for with several coats of die spacer.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12886207     DOI: 10.1016/s0022-3913(03)00276-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  12 in total

1.  Comparative evaluation of dimensional accuracy of different polyvinyl siloxane putty-wash impression techniques-in vitro study.

Authors:  Ramandeep Dugal; Bhargavi Railkar; Smita Musani
Journal:  J Int Oral Health       Date:  2013-10-26

2.  Influence of material surface on the scanning error of a powder-free 3D measuring system.

Authors:  Michael Kurz; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2015-03-07       Impact factor: 3.573

3.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

4.  In vivo Study of the Accuracy of Dual-arch Impressions.

Authors:  Luciana Martinelli Santayana de Lima; Gilberto Antonio Borges; Luiz Henrique Burnett Junior; Ana Maria Spohr
Journal:  J Int Oral Health       Date:  2014-06-26

5.  A Comparative Evaluation of the Linear Dimensional Accuracy of Four Impression Techniques using Polyether Impression Material.

Authors:  Smita Sara Manoj; K P Cherian; Vidya Chitre; Meena Aras
Journal:  J Indian Prosthodont Soc       Date:  2013-02-06

6.  Influence of Custom Trays, Dual-Arch Passive, Flexed Trays and Viscosities of Elastomeric Impression Materials on Working Dies.

Authors:  Mansi Arora; Shivani Kohli; Rupali Kalsi
Journal:  J Clin Diagn Res       Date:  2016-05-01

7.  A Comparative Evaluation of Accuracy of the Dies Affected by Tray Type, Material Viscosity, and Pouring Sequence of Dual and Single Arch Impressions- An In vitro Study.

Authors:  Poonam R Kulkarni; Rahul S Kulkarni; Rupal J Shah; Rahul Chhajlani; Bhuwan Saklecha; Kavita Maru
Journal:  J Clin Diagn Res       Date:  2017-04-01

8.  A Comparison of Dimensional Accuracy of Addition Silicone of Different Consistencies with Two Different Spacer Designs - In-vitro Study.

Authors:  Suprabha Rathee; B Eswaran; Ma Eswaran; R Prabhu; Kr Geetha; Gp Krishna
Journal:  J Clin Diagn Res       Date:  2014-07-20

9.  Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

Authors:  Ye-Kyu Rhee; Yoon-Hyuk Huh; Lee-Ra Cho; Chan-Jin Park
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

10.  Comparison of digital and conventional impression techniques: evaluation of patients' perception, treatment comfort, effectiveness and clinical outcomes.

Authors:  Emir Yuzbasioglu; Hanefi Kurt; Rana Turunc; Halenur Bilir
Journal:  BMC Oral Health       Date:  2014-01-30       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.