Literature DB >> 25032765

Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth.

Beatriz Giménez, Mutlu Özcan, Francisco Martínez-Rus, Guillermo Pradíes.   

Abstract

PURPOSE: To evaluate the accuracy of a digital impression system based on parallel confocal red laser technology, taking into consideration clinical parameters such as operator experience and angulation and depth of implants.
MATERIALS AND METHODS: A maxillary master model with six implants (located bilaterally in the second molar, second premolar, and lateral incisor positions) was fitted with six polyether ether ketone scan bodies. One second premolar implant was placed with 30 degrees of mesial angulation; the opposite implant was positioned with 30 degrees of distal angulation. The lateral incisor implants were placed 2 or 4 mm subgingivally. Two experienced and two inexperienced operators performed intraoral scanning. Five different interimplant distances were then measured. The files obtained from the scans were imported with reverse-engineering software. Measurements were then made with a coordinate measurement machine, with values from the master model used as reference values. The deviations from the actual values were then calculated. The differences between experienced and inexperienced operators and the effects of different implant angulations and depths were compared statistically.
RESULTS: Overall, operator 3 obtained significantly less accurate results. The angulated implants did not significantly influence accuracy compared to the parallel implants. Differences were found in the amount of error in the different quadrants. The second scanned quadrant had significantly worse results than the first scanned quadrant. Impressions of the implants placed at the tissue level were less accurate than implants placed 2 and 4 mm subgingivally.
CONCLUSIONS: The operator affected the accuracy of measurements, but the performance of the operator was not necessarily dependent on experience. Angulated implants did not decrease the accuracy of the digital impression system tested. The scanned distance affected the predictability of the accuracy of the scanner, and the error increased with the increased length of the scanned section.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25032765     DOI: 10.11607/jomi.3343

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  19 in total

1.  In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants.

Authors:  Leonardo Ciocca; Roberto Meneghello; Carlo Monaco; Gianpaolo Savio; Lorenzo Scheda; Maria Rosaria Gatto; Paolo Baldissara
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-03-02       Impact factor: 2.924

2.  A new 3D-method to assess the inter implant dimensions in patients - A pilot study.

Authors:  Alexander Schmidt; Jan-Wilhelm Billig; Maximiliane A Schlenz; Bernd Wöstmann
Journal:  J Clin Exp Dent       Date:  2020-02-01

Review 3.  Precision and practical usefulness of intraoral scanners in implant dentistry: A systematic literature review.

Authors:  Ignacio García-Gil; Jorge Cortés-Bretón-Brinkmann; Jaime Jiménez-García; Jesus Peláez-Rico; María-Jesús Suárez-García
Journal:  J Clin Exp Dent       Date:  2020-08-01

4.  Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study.

Authors:  Gülce Çakmak; Hakan Yilmaz; Alejandro Treviño Santos; Ali Murat Kökat; Burak Yilmaz
Journal:  J Prosthodont       Date:  2021-09-21       Impact factor: 3.485

5.  Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

Authors:  Ye-Kyu Rhee; Yoon-Hyuk Huh; Lee-Ra Cho; Chan-Jin Park
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

6.  Influence of Scanner Precision and Analysis Software in Quantifying Three-Dimensional Intraoral Changes: Two-Factor Factorial Experimental Design.

Authors:  Saoirse O'Toole; David Bartlett; Andrew Keeling; John McBride; Eduardo Bernabe; Luuk Crins; Bas Loomans
Journal:  J Med Internet Res       Date:  2020-11-27       Impact factor: 5.428

7.  Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

Authors:  Fan Zhang; Kyung-Jin Suh; Kyung-Min Lee
Journal:  PLoS One       Date:  2016-06-15       Impact factor: 3.240

Review 8.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

Review 9.  Assessment of intraoral scanning technology for multiple implant impressions - A systematic review and meta-analysis.

Authors:  Saloni Kachhara; Deepak Nallaswamy; Dhanraj M Ganapathy; Vinay Sivaswamy; Vaishnavi Rajaraman
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

10.  Trueness and Precision of Three-Dimensional Digitizing Intraoral Devices.

Authors:  Hussam Mutwalli; Michael Braian; Deyar Mahmood; Christel Larsson
Journal:  Int J Dent       Date:  2018-11-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.