Literature DB >> 26778689

Measuring B1 distributions by B1 phase encoding.

Kalina V Jordanova1, Dwight G Nishimura1, Adam B Kerr1.   

Abstract

PURPOSE: We propose a method to acquire B1 distribution plots by encoding in B1 instead of image space. Using this method, B1 data is acquired in a different way from traditional spatial B1 mapping, and allows for quick measurement of high dynamic range B1 data.
METHODS: To encode in B1, we acquire multiple projections of a slice, each along the same direction, but using a different phase sensitivity to B1. Using a convex optimization formulation, we reconstruct histograms of the B1 distribution estimates of the slice.
RESULTS: We verify in vivo B1 distribution measurements by comparing measured distributions to distributions calculated from reference spatial B1 maps using the Earth Mover's Distance. Phantom measurements using a surface coil show that for increased spatial B1 variations, measured B1 distributions using the proposed method more accurately estimate the distribution than a low-resolution spatial B1 map, resulting in a 37% Earth Mover's Distance decrease while using fewer measurements.
CONCLUSION: We propose and validate the performance of a method to acquire B1 distribution information directly without acquiring a spatial B1 map. The method may provide faster estimates of a B1 field for applications that do not require spatial B1 localization, such as the transmit gain calibration of the scanner, particularly for high dynamic B1 ranges. Magn Reson Med 77:229-236, 2017.
© 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  zzm321990B1 distributions; zzm321990B1 mapping

Mesh:

Year:  2016        PMID: 26778689      PMCID: PMC4947573          DOI: 10.1002/mrm.26114

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

2.  DREAM--a novel approach for robust, ultrafast, multislice B₁ mapping.

Authors:  Kay Nehrke; Peter Börnert
Journal:  Magn Reson Med       Date:  2012-01-17       Impact factor: 4.668

3.  Fast, accurate, and precise mapping of the RF field in vivo using the 180 degrees signal null.

Authors:  Nicholas G Dowell; Paul S Tofts
Journal:  Magn Reson Med       Date:  2007-09       Impact factor: 4.668

4.  Transmit gain calibration for nonproton MR using the Bloch-Siegert shift.

Authors:  Rolf F Schulte; Laura Sacolick; Martin H Deppe; Martin A Janich; Markus Schwaiger; Jim M Wild; Florian Wiesinger
Journal:  NMR Biomed       Date:  2011-03-08       Impact factor: 4.044

5.  Lowering the B1 threshold for improved BEAR B1 mapping.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

6.  Magnetic field mapping.

Authors:  J P Hornak; J Szumowski; R G Bryant
Journal:  Magn Reson Med       Date:  1988-02       Impact factor: 4.668

7.  Rapid B1 mapping using orthogonal, equal-amplitude radio-frequency pulses.

Authors:  Yulin V Chang
Journal:  Magn Reson Med       Date:  2011-06-28       Impact factor: 4.668

8.  Calibration of RF transmitter voltages for hyperpolarized gas MRI.

Authors:  Adil Bashir; Mark S Conradi; Jason C Woods; James D Quirk; Ddmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

9.  B1 estimation using adiabatic refocusing: BEAR.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2013-11-22       Impact factor: 4.668

10.  Accurate flip-angle calibration for 13C MRI.

Authors:  Ileana Hancu; Ronald Watkins; Susan J Kohler; Richard P Mallozzi
Journal:  Magn Reson Med       Date:  2007-07       Impact factor: 3.737

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.