Fast, accurate, and precise mapping of the RF field in vivo using the 180 degrees signal null.

Nicholas G Dowell1, Paul S Tofts.   

Abstract

RF field B1 nonuniformity is the largest cause of error in the quantitative measurement of many clinically relevant parameters in MR images and spectra. Knowledge of the absolute flip angles at every region will improve the accuracy and precision of such parameters. This method uses the 180 degrees signal null to construct a flip angle map of the entire brain in less than 4 min, independent of T1, T2, and proton density. Three spoiled gradient echo volume acquisitions of the whole brain were made with three different flip angles. The optimum choice of flip angles was determined to be 145 degrees, 180 degrees, and 215 degrees. Linear regression analysis was used to determine the nominal (system calibrated) flip angle required for a signal null at every pixel and thence determine the absolute flip angle at that location. The experiment utilizes an existing MR sequence supplied by the scanner manufacturer. The technique is validated experimentally and a theoretical investigation into the optimum experimental parameters is presented. Copyright (c) 2007 Wiley-Liss, Inc.

Mesh:

Substances:

Year:  2007        PMID: 17763355     DOI: 10.1002/mrm.21368

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  46 in total

Review 1.  Multicentre imaging measurements for oncology and in the brain.

Authors:  P S Tofts; D J Collins
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

3.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

4.  Measuring B1 distributions by B1 phase encoding.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2016-01-17       Impact factor: 4.668

5.  Accurate T1 mapping of short T2 tissues using a three-dimensional ultrashort echo time cones actual flip angle imaging-variable repetition time (3D UTE-Cones AFI-VTR) method.

Authors:  Ya-Jun Ma; Xing Lu; Michael Carl; Yanchun Zhu; Nikolaus M Szeverenyi; Graeme M Bydder; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2018-01-03       Impact factor: 4.668

6.  Improved localization, spectral quality, and repeatability with advanced MRS methodology in the clinical setting.

Authors:  Dinesh K Deelchand; Kejal Kantarci; Gülin Öz
Journal:  Magn Reson Med       Date:  2017-06-15       Impact factor: 4.668

7.  Rapid B1 field mapping at 3 T using the 180° signal null method with extended flip angle.

Authors:  Abinand C Rejimon; Diana Y Lee; Christopher M Bergeron; You Zhuo; Wenshu Qian; Richard G Spencer; Mustapha Bouhrara
Journal:  Magn Reson Imaging       Date:  2018-06-26       Impact factor: 2.546

8.  Lowering the B1 threshold for improved BEAR B1 mapping.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

9.  Modification of population based arterial input function to incorporate individual variation.

Authors:  Harrison Kim
Journal:  Magn Reson Imaging       Date:  2017-09-27       Impact factor: 2.546

10.  Slice profile and B1 corrections in 2D magnetic resonance fingerprinting.

Authors:  Dan Ma; Simone Coppo; Yong Chen; Debra F McGivney; Yun Jiang; Shivani Pahwa; Vikas Gulani; Mark A Griswold
Journal:  Magn Reson Med       Date:  2017-01-11       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.