Literature DB >> 21713982

Rapid B1 mapping using orthogonal, equal-amplitude radio-frequency pulses.

Yulin V Chang1.   

Abstract

We present a new phase-based method for mapping the amplitude of the radio-frequency field (B(1) ) of a transmitter coil in three-dimension. This method exploits the noncommutation relation between rotations about orthogonal axes. Our implementation of this principle in the current work results in a simple relation between the phase of the final magnetization and the flip angle (FA). In this study, we focus on FAs less than 90°. Our method is rapid and easy to implement compared with the existing B(1) mapping schemes. The mapping sequence can be simply obtained by adding to a regular three-dimensional gradient-echo sequence a magnetization preparation radio-frequency pulse of the same FA but orthogonal in phase to the excitation radio-frequency pulse. This method is demonstrated capable of generating reliable maps of the B(1) field within 1 min using FAs no larger than 60°. We show that it is robust against T(1), small chemical shift, and mild background inhomogeneity. This method may especially be suitable for B(1) mapping in situations (e.g., long-T(1) and hyperpolarized-gas imaging) where magnitude-based methods are not readily applicable. A noise calculation of the FA map using this method is also presented.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21713982      PMCID: PMC4638182          DOI: 10.1002/mrm.23051

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  14 in total

1.  Signal-to-noise in phase angle reconstruction: dynamic range extension using phase reference offsets.

Authors:  T E Conturo; G D Smith
Journal:  Magn Reson Med       Date:  1990-09       Impact factor: 4.668

2.  Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

3.  Saturated double-angle method for rapid B1+ mapping.

Authors:  Charles H Cunningham; John M Pauly; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2006-06       Impact factor: 4.668

4.  Fast 3D radiofrequency field mapping using echo-planar imaging.

Authors:  F Jiru; U Klose
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

5.  Fast, accurate, and precise mapping of the RF field in vivo using the 180 degrees signal null.

Authors:  Nicholas G Dowell; Paul S Tofts
Journal:  Magn Reson Med       Date:  2007-09       Impact factor: 4.668

6.  A phase-sensitive method of flip angle mapping.

Authors:  Glen R Morrell
Journal:  Magn Reson Med       Date:  2008-10       Impact factor: 4.668

7.  Imaging of the active B1 field in vivo.

Authors:  R Stollberger; P Wach
Journal:  Magn Reson Med       Date:  1996-02       Impact factor: 4.668

8.  Magnetic field mapping.

Authors:  J P Hornak; J Szumowski; R G Bryant
Journal:  Magn Reson Med       Date:  1988-02       Impact factor: 4.668

9.  Quantitative in vivo assessment of lung microstructure at the alveolar level with hyperpolarized 3He diffusion MRI.

Authors:  Dmitriy A Yablonskiy; Alexander L Sukstanskii; Jason C Leawoods; David S Gierada; G Larry Bretthorst; Stephen S Lefrak; Joel D Cooper; Mark S Conradi
Journal:  Proc Natl Acad Sci U S A       Date:  2002-02-26       Impact factor: 11.205

10.  Calibration of RF transmitter voltages for hyperpolarized gas MRI.

Authors:  Adil Bashir; Mark S Conradi; Jason C Woods; James D Quirk; Ddmitriy A Yablonskiy
Journal:  Magn Reson Med       Date:  2009-01       Impact factor: 4.668

View more
  6 in total

1.  Mapping of low flip angles in magnetic resonance.

Authors:  Fabien Balezeau; Pierre-Antoine Eliat; Alejandro Bordelois Cayamo; Hervé Saint-Jalmes
Journal:  Phys Med Biol       Date:  2011-09-23       Impact factor: 3.609

2.  Measuring B1 distributions by B1 phase encoding.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2016-01-17       Impact factor: 4.668

3.  Lowering the B1 threshold for improved BEAR B1 mapping.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

4.  B1 estimation using adiabatic refocusing: BEAR.

Authors:  Kalina V Jordanova; Dwight G Nishimura; Adam B Kerr
Journal:  Magn Reson Med       Date:  2013-11-22       Impact factor: 4.668

5.  Ultrafast 3D Bloch-Siegert B <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"><mml:msubsup><mml:mrow/> <mml:mn>1</mml:mn> <mml:mo>+</mml:mo></mml:msubsup> </mml:math> -mapping using variational modeling.

Authors:  Andreas Lesch; Matthias Schlöegl; Martin Holler; Kristian Bredies; Rudolf Stollberger
Journal:  Magn Reson Med       Date:  2018-10-12       Impact factor: 4.668

6.  Characterization of phase-based methods used for transmission field uniformity mapping: a magnetic resonance study at 3.0 T and 7.0 T.

Authors:  Flavio Carinci; Davide Santoro; Federico von Samson-Himmelstjerna; Tomasz Dawid Lindel; Matthias Alexander Dieringer; Thoralf Niendorf
Journal:  PLoS One       Date:  2013-03-05       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.