Application of intelligent optimal kV scanning technology (CARE kV) in dual-source computed tomography (DSCT) coronary angiography.

Jun Zhang1, Shaolei Kang2, Dan Han2, Xiaojie Xie2, Yaming Deng2.   

Abstract

This study aims to evaluate the applications and values of dual-source computed tomography (DSCT) intelligent optimal kV scanning technology (CARE kV) in coronary CT angiography (CCTA). 150 patients with normal body mass index were performed DSCT coronary angiography, then randomly divided into the "Semi", 120,100 and 80 kV Group, and the 2 "on" groups, with 30 patients in each group. The first 5 groups used the reference voltage as 120 kV, and the reference current as 400 mAs, while the other group used the reference voltage as 100 kV, and the reference current as 400 mAs. The image quality, average CT value, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and radiation dose were comparatively analyzed among the 5 groups. The image quality scores of the five groups showed no significant difference (P > 0.05); the average CT values and image noises had significance (P < 0.05), while SNR and CNR showed no significant difference (P > 0.05). The 80 kV group showed the biggest noise, with the CT value as 700 HU, while the radiation dose was the lowest, followed by the on group. As for the patients with normal body mass index (BMI), CARE kV-"on" could obtain high-quality images and lower radiation dose for CCTA, while the operation was simple and convenient.

Entities:  

Keywords:  CARE kV; Tomography; X-ray computer; coronary angiography; radiation dose

Year:  2015        PMID: 26770354      PMCID: PMC4694254     

Source DB:  PubMed          Journal:  Int J Clin Exp Med        ISSN: 1940-5901


  23 in total

1.  Automatic Tube Potential Selection with Tube Current Modulation (APSCM) in coronary CT angiography: Comparison of image quality and radiation dose with conventional body mass index-based protocol.

Authors:  Young Jean Park; Young Jin Kim; Ji Won Lee; Hee Yeong Kim; Yoo Jin Hong; Hye-Jeong Lee; Jin Hur; Ji Eun Nam; Byoung Wook Choi
Journal:  J Cardiovasc Comput Tomogr       Date:  2012-04-06

2.  Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction.

Authors:  Michaela M Hell; Daniel Bittner; Annika Schuhbaeck; Gerd Muschiol; Michael Brand; Michael Lell; Michael Uder; Stephan Achenbach; Mohamed Marwan
Journal:  J Cardiovasc Comput Tomogr       Date:  2014-09-16

Review 3.  CT myocardial perfusion imaging.

Authors:  Akos Varga-Szemes; Felix G Meinel; Carlo N De Cecco; Stephen R Fuller; Richard R Bayer; U Joseph Schoepf
Journal:  AJR Am J Roentgenol       Date:  2015-03       Impact factor: 3.959

4.  Comparison of 128-Slice Dual Source CT Coronary Angiography with Invasive Coronary Angiography.

Authors:  Rajneesh Madhok; Abhinav Aggarwal
Journal:  J Clin Diagn Res       Date:  2014-06-20

5.  Interobserver variability of CT angiography for evaluation of aortic annulus dimensions prior to transcatheter aortic valve implantation (TAVI).

Authors:  C Schmidkonz; M Marwan; L Klinghammer; M Mitschke; A Schuhbaeck; M Arnold; M Lell; S Achenbach; T Pflederer
Journal:  Eur J Radiol       Date:  2014-06-19       Impact factor: 3.528

6.  Iterative image reconstruction algorithms in coronary CT angiography improve the detection of lipid-core plaque--a comparison with histology.

Authors:  Stefan B Puchner; Maros Ferencik; Pal Maurovich-Horvat; Masataka Nakano; Fumiyuki Otsuka; Hans-Ulrich Kauczor; Renu Virmani; Udo Hoffmann; Christopher L Schlett
Journal:  Eur Radiol       Date:  2014-09-03       Impact factor: 5.315

7.  Truncus arteriosus: Diagnosis with dual-source computed tomography angiography and low radiation dose.

Authors:  Mustafa Koplay; Derya Cimen; Mesut Sivri; Osman Güvenc; Derya Arslan; Alaaddin Nayman; Bulent Oran
Journal:  World J Radiol       Date:  2014-11-28

8.  Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: a phantom study.

Authors:  Felix G Meinel; Christian Canstein; U Joseph Schoepf; Martin Sedlmaier; Bernhard Schmidt; Brett S Harris; Thomas G Flohr; Carlo N De Cecco
Journal:  Eur Radiol       Date:  2014-05-10       Impact factor: 5.315

9.  Cardiac computed tomography angiography with automatic tube potential selection: effects on radiation dose and image quality.

Authors:  Brian B Ghoshhajra; Leif-Christopher Engel; Mihály Károlyi; Manavjot Singh Sidhu; Bryan Wai; Mitya Barreto; Uthamalingam Shanmugam; Udo Hoffmann; Thomas J Brady; Manudeep Kalra; Suhny Abbara
Journal:  J Thorac Imaging       Date:  2013-01       Impact factor: 3.000

10.  A rare case of single right coronary artery with congenital absence of left coronary artery in an adult: a case report.

Authors:  Fengli Fu; Hongfeng Jin; Yue Feng
Journal:  J Cardiothorac Surg       Date:  2015-04-21       Impact factor: 1.637

View more
  3 in total

Review 1.  Low tube voltage prospectively ECG-triggered coronary CT angiography: a systematic review of image quality and radiation dose.

Authors:  Sock Keow Tan; Chai Hong Yeong; Raja Rizal Azman Raja Aman; Kwan Hoong Ng; Yang Faridah Abdul Aziz; Kok Han Chee; Zhonghua Sun
Journal:  Br J Radiol       Date:  2018-03-29       Impact factor: 3.039

2.  Validation of CARE kV automated tube voltage selection for PET-CT: PET quantification and CT radiation dose reduction in phantoms.

Authors:  Natalie A Bebbington; Troels Jørgensen; Erik Dupont; Mille A Micheelsen
Journal:  EJNMMI Phys       Date:  2021-03-20

3.  Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels.

Authors:  Zhenlin Li; Jinge Zhang; Chunchao Xia; Fei Zhao; Kai Zhang; Yuming Li; Lei Li; Jin Pu; Wanlin Peng; Keling Liu; Yingkun Guo
Journal:  Ann Transl Med       Date:  2020-08
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.