Literature DB >> 25121042

Comparison of 128-Slice Dual Source CT Coronary Angiography with Invasive Coronary Angiography.

Rajneesh Madhok1, Abhinav Aggarwal2.   

Abstract

BACKGROUND: Coronary artery disease (CAD) is one of the leading cause of the morbidity and mortality in India as well as worldwide and last decade has seen a steep rise in incidence of CAD in India. Direct visualization of the coronary arteries by invasive catheterization still represents the cornerstone of the evaluation of CAD. Cardiac imaging is a challenge of 21 (st) century and is being answered by 128 slice dual source CT as it has good temporal resolution, high scanning speed as well as low radiation dose. AIM: To assess the diagnostic accuracy of 128-slice dual source CT Cardiac Angiography in comparison with Conventional Catheter Cardiac Angiography.
MATERIALS AND METHODS: Forty patients attending the cardiology OPD with complaint of chest pain and suspected of having CAD were evaluated by CT coronary angiography and conventional invasive Catheter coronary angiography and the results were compared. All patients were checked for serum creatinine and ECG before the angiography. Computed Tomography (CT) coronary angiography was done using SIEMENS 128-slice Dual Source Flash Definition CT Scanner under either Retrospective or Prospective mode depending on the heart rate of the patient. Oral/IV beta-blocker were used whenever required.
RESULTS: Coronary arteries were assessed as per 17- segment AHA model. A total of 600/ 609 segments were evaluable in 40 suspected patients on CT coronary angiography, of which 21 were false positives and 8 were false negatives with specificity of 95.12% and sensitivity and positive predictive value of 95.26% & 88.46% respectively.
CONCLUSION: Non-invasive assessment of CAD is now possible with high accuracy on 128-slice dual source CT scanner.

Entities:  

Keywords:  Cardiac angiography; Cardiac imaging; Invasive

Year:  2014        PMID: 25121042      PMCID: PMC4129286          DOI: 10.7860/JCDR/2014/9568.4514

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  11 in total

1.  Coronary artery imaging with multidetector CT: visualization issues.

Authors:  Peter M A van Ooijen; Kai Yiu Ho; Joost Dorgelo; Matthijs Oudkerk
Journal:  Radiographics       Date:  2003-08-07       Impact factor: 5.333

Review 2.  Coronary artery disease in India.

Authors:  Soumitra Kumar
Journal:  J Indian Med Assoc       Date:  2009-09

3.  Accuracy of 64-MDCT in the diagnosis of ischemic heart disease.

Authors:  Konstantin Nikolaou; Andreas Knez; Carsten Rist; Bernd J Wintersperger; Alexander Leber; Thorsten Johnson; Maximilian F Reiser; Christoph R Becker
Journal:  AJR Am J Roentgenol       Date:  2006-07       Impact factor: 3.959

4.  High-resolution spiral computed tomography coronary angiography in patients referred for diagnostic conventional coronary angiography.

Authors:  Nico R Mollet; Filippo Cademartiri; Carlos A G van Mieghem; Giuseppe Runza; Eugène P McFadden; Timo Baks; Patrick W Serruys; Gabriel P Krestin; Pim J de Feyter
Journal:  Circulation       Date:  2005-10-03       Impact factor: 29.690

5.  Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window.

Authors:  A F Kopp; S Schroeder; A Kuettner; M Heuschmid; C Georg; B Ohnesorge; R Kuzo; C D Claussen
Journal:  Radiology       Date:  2001-12       Impact factor: 11.105

6.  Accuracy of MSCT coronary angiography with 64-slice technology: first experience.

Authors:  Sebastian Leschka; Hatem Alkadhi; André Plass; Lotus Desbiolles; Jürg Grünenfelder; Borut Marincek; Simon Wildermuth
Journal:  Eur Heart J       Date:  2005-04-19       Impact factor: 29.983

7.  Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography.

Authors:  Gilbert L Raff; Michael J Gallagher; William W O'Neill; James A Goldstein
Journal:  J Am Coll Cardiol       Date:  2005-08-02       Impact factor: 24.094

8.  Diagnostic value of 64-slice multi-detector row cardiac CTA in symptomatic patients.

Authors:  Georg Mühlenbruch; Tobias Seyfarth; Chee Siong Soo; Namasivayam Pregalathan; Andreas Horst Mahnken
Journal:  Eur Radiol       Date:  2006-09-29       Impact factor: 5.315

9.  Prognostic value of coronary electron-beam computed tomography for coronary heart disease events in asymptomatic populations.

Authors:  P G O'Malley; A J Taylor; J L Jackson; T M Doherty; R C Detrano
Journal:  Am J Cardiol       Date:  2000-04-15       Impact factor: 2.778

10.  Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy.

Authors:  Harald Brodoefel; Christof Burgstahler; Ilias Tsiflikas; Anja Reimann; Stephen Schroeder; Claus D Claussen; Martin Heuschmid; Andreas F Kopp
Journal:  Radiology       Date:  2008-03-27       Impact factor: 11.105

View more
  2 in total

1.  Application of intelligent optimal kV scanning technology (CARE kV) in dual-source computed tomography (DSCT) coronary angiography.

Authors:  Jun Zhang; Shaolei Kang; Dan Han; Xiaojie Xie; Yaming Deng
Journal:  Int J Clin Exp Med       Date:  2015-10-15

2.  Integrated non-invasive approach to atherosclerosis with cardiac CT and carotid ultrasound in patients with suspected coronary artery disease.

Authors:  Ludovico La Grutta; Marta Marasà; Patrizia Toia; Daniele Ajello; Domenico Albano; Erica Maffei; Emanuele Grassedonio; Giuseppina Novo; Massimo Galia; Giuseppe Caruso; Salvatore Novo; Filippo Cademartiri; Massimo Midiri
Journal:  Radiol Med       Date:  2016-10-13       Impact factor: 3.469

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.