Literature DB >> 26756964

Coil-to-coil physiological noise correlations and their impact on functional MRI time-series signal-to-noise ratio.

Christina Triantafyllou1, Jonathan R Polimeni2, Boris Keil2, Lawrence L Wald2,3.   

Abstract

PURPOSE: Physiological nuisance fluctuations ("physiological noise") are a major contribution to the time-series signal-to-noise ratio (tSNR) of functional imaging. While thermal noise correlations between array coil elements have a well-characterized effect on the image Signal to Noise Ratio (SNR0 ), the element-to-element covariance matrix of the time-series fluctuations has not yet been analyzed. We examine this effect with a goal of ultimately improving the combination of multichannel array data. THEORY AND METHODS: We extend the theoretical relationship between tSNR and SNR0 to include a time-series noise covariance matrix Ψt , distinct from the thermal noise covariance matrix Ψ0 , and compare its structure to Ψ0 and the signal coupling matrix SSH formed from the signal intensity vectors S.
RESULTS: Inclusion of the measured time-series noise covariance matrix into the model relating tSNR and SNR0 improves the fit of experimental multichannel data and is shown to be distinct from Ψ0 or SSH .
CONCLUSION: Time-series noise covariances in array coils are found to differ from Ψ0 and more surprisingly, from the signal coupling matrix SSH . Correct characterization of the time-series noise has implications for the analysis of time-series data and for improving the coil element combination process. Magn Reson Med 76:1708-1719, 2016.
© 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  32Channel coil; 7T; SNR; array coils; fMRI; noise covariance; physiological noise

Mesh:

Year:  2016        PMID: 26756964      PMCID: PMC5565210          DOI: 10.1002/mrm.26041

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Segmentation of brain MR images through a hidden Markov random field model and the expectation-maximization algorithm.

Authors:  Y Zhang; M Brady; S Smith
Journal:  IEEE Trans Med Imaging       Date:  2001-01       Impact factor: 10.048

2.  Improved optimization for the robust and accurate linear registration and motion correction of brain images.

Authors:  Mark Jenkinson; Peter Bannister; Michael Brady; Stephen Smith
Journal:  Neuroimage       Date:  2002-10       Impact factor: 6.556

3.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

5.  Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters.

Authors:  C Triantafyllou; R D Hoge; G Krueger; C J Wiggins; A Potthast; G C Wiggins; L L Wald
Journal:  Neuroimage       Date:  2005-05-15       Impact factor: 6.556

6.  Signal-to-noise measurements in magnitude images from NMR phased arrays.

Authors:  C D Constantinides; E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-11       Impact factor: 4.668

7.  The Rician distribution of noisy MRI data.

Authors:  H Gudbjartsson; S Patz
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

8.  On-line automatic slice positioning for brain MR imaging.

Authors:  André J W van der Kouwe; Thomas Benner; Bruce Fischl; Franz Schmitt; David H Salat; Martin Harder; A Gregory Sorensen; Anders M Dale
Journal:  Neuroimage       Date:  2005-08-01       Impact factor: 6.556

9.  Physiological noise and signal-to-noise ratio in fMRI with multi-channel array coils.

Authors:  Christina Triantafyllou; Jonathan R Polimeni; Lawrence L Wald
Journal:  Neuroimage       Date:  2010-12-16       Impact factor: 6.556

10.  Modelling temporal stability of EPI time series using magnitude images acquired with multi-channel receiver coils.

Authors:  Chloe Hutton; Evelyne Balteau; Antoine Lutti; Oliver Josephs; Nikolaus Weiskopf
Journal:  PLoS One       Date:  2012-12-20       Impact factor: 3.240

View more
  11 in total

1.  Mapping the human subcortical auditory system using histology, postmortem MRI and in vivo MRI at 7T.

Authors:  Kevin R Sitek; Omer Faruk Gulban; Satrajit S Ghosh; Federico De Martino; Evan Calabrese; G Allan Johnson; Agustin Lage-Castellanos; Michelle Moerel
Journal:  Elife       Date:  2019-08-01       Impact factor: 8.140

Review 2.  Impacting the effect of fMRI noise through hardware and acquisition choices - Implications for controlling false positive rates.

Authors:  Lawrence L Wald; Jonathan R Polimeni
Journal:  Neuroimage       Date:  2016-12-28       Impact factor: 6.556

3.  Optimized partial-coverage functional analysis pipeline (OPFAP): a semi-automated pipeline for skull stripping and co-registration of partial-coverage, ultra-high-field functional images.

Authors:  Peter E Yoo; Jon O Cleary; Scott C Kolbe; Roger J Ordidge; Terence J O'Brien; Nicholas L Opie; Sam E John; Thomas J Oxley; Bradford A Moffat
Journal:  MAGMA       Date:  2018-05-29       Impact factor: 2.310

4.  Intracortical smoothing of small-voxel fMRI data can provide increased detection power without spatial resolution losses compared to conventional large-voxel fMRI data.

Authors:  Anna I Blazejewska; Bruce Fischl; Lawrence L Wald; Jonathan R Polimeni
Journal:  Neuroimage       Date:  2019-01-25       Impact factor: 6.556

5.  Reduction of across-run variability of temporal SNR in accelerated EPI time-series data through FLEET-based robust autocalibration.

Authors:  Anna I Blazejewska; Himanshu Bhat; Lawrence L Wald; Jonathan R Polimeni
Journal:  Neuroimage       Date:  2017-02-20       Impact factor: 6.556

Review 6.  Methods for cleaning the BOLD fMRI signal.

Authors:  César Caballero-Gaudes; Richard C Reynolds
Journal:  Neuroimage       Date:  2016-12-09       Impact factor: 6.556

7.  An 8-dipole transceive and 24-loop receive array for non-human primate head imaging at 10.5 T.

Authors:  Russell L Lagore; Steen Moeller; Jan Zimmermann; Lance DelaBarre; Jerahmie Radder; Andrea Grant; Kamil Ugurbil; Essa Yacoub; Noam Harel; Gregor Adriany
Journal:  NMR Biomed       Date:  2021-01-29       Impact factor: 4.044

8.  Analysis of physiological noise in quantitative cardiac magnetic resonance.

Authors:  Terrence Jao; Krishna Nayak
Journal:  PLoS One       Date:  2019-08-27       Impact factor: 3.240

9.  An in-vivo study of BOLD laminar responses as a function of echo time and static magnetic field strength.

Authors:  Irati Markuerkiaga; José P Marques; Lauren J Bains; David G Norris
Journal:  Sci Rep       Date:  2021-01-21       Impact factor: 4.379

10.  Feasibility of identifying the ideal locations for motor intention decoding using unimodal and multimodal classification at 7T-fMRI.

Authors:  Peter E Yoo; Thomas J Oxley; Sam E John; Nicholas L Opie; Roger J Ordidge; Terence J O'Brien; Maureen A Hagan; Yan T Wong; Bradford A Moffat
Journal:  Sci Rep       Date:  2018-10-22       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.