Literature DB >> 26714967

Combination of two-dimensional shear wave elastography with ultrasound breast imaging reporting and data system in the diagnosis of breast lesions: a new method to increase the diagnostic performance.

Dan-Dan Li1,2, Hui-Xiong Xu3,4, Le-Hang Guo1,2, Xiao-Wan Bo1,2, Xiao-Long Li1,2, Rong Wu1,2, Jun-Mei Xu1,2, Yi-Feng Zhang1,2, Kun Zhang1,2.   

Abstract

OBJECTIVES: To evaluate the diagnostic performance of a new method of combined two-dimensional shear wave elastography (i.e. virtual touch imaging quantification, VTIQ) and ultrasound (US) Breast Imaging Reporting and Data System (BI-RADS) in the differential diagnosis of breast lesions.
MATERIALS AND METHODS: From September 2014 to December 2014, 276 patients with 296 pathologically proven breast lesions were enrolled in this study. The conventional US images were interpreted by two independent readers. The diagnosis performances of BI-RADS and combined BI-RADS and VTIQ were evaluated, including the area under the receiver operating characteristic curve (AUROC), sensitivity and specificity. Observer consistency was also evaluated.
RESULTS: Pathologically, 212 breast lesions were benign and 84 were malignant. Compared with BI-RADS alone, the AUROCs and specificities of the combined method for both readers increased significantly (AUROC: 0.862 vs. 0.693 in reader 1, 0.861 vs. 0.730 in reader 2; specificity: 91.5 % vs. 38.7 % in reader 1, 94.8 % vs. 47.2 % in reader 2; all P < .05). The Kappa value between the two readers for BI-RADS assessment was 0.614, and 0.796 for the combined method.
CONCLUSION: The combined VTIQ and BI-RADS had a better diagnostic performance in the diagnosis of breast lesions in comparison with BI-RADS alone. KEY POINTS: • Combination of conventional ultrasound and elastography distinguishes breast cancers more effectively. • Combination of conventional ultrasound and elastography increases observer consistency. • BI-RADS weights more than the 2D-SWE with an increase in malignancy probability.

Entities:  

Keywords:  Breast; Breast Imaging Reporting and Data System (BI-RADS); Cancer; Two-dimensional shear wave elastography; Ultrasound

Mesh:

Year:  2015        PMID: 26714967     DOI: 10.1007/s00330-015-4163-8

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  33 in total

Review 1.  Sonographic breast elastography: a primer.

Authors:  Richard G Barr
Journal:  J Ultrasound Med       Date:  2012-05       Impact factor: 2.153

2.  Shear wave imaging of the breast: still on the learning curve.

Authors:  Richard G Barr
Journal:  J Ultrasound Med       Date:  2012-03       Impact factor: 2.153

3.  Shear-wave elastography improves the specificity of breast US: the BE1 multinational study of 939 masses.

Authors:  Wendie A Berg; David O Cosgrove; Caroline J Doré; Fritz K W Schäfer; William E Svensson; Regina J Hooley; Ralf Ohlinger; Ellen B Mendelson; Catherine Balu-Maestro; Martina Locatelli; Christophe Tourasse; Barbara C Cavanaugh; Valérie Juhan; A Thomas Stavros; Anne Tardivon; Joel Gay; Jean-Pierre Henry; Claude Cohen-Bacrie
Journal:  Radiology       Date:  2012-02       Impact factor: 11.105

4.  Normal breast tissue stiffness measured by a new ultrasound technique: virtual touch tissue imaging quantification (VTIQ).

Authors:  Michael Golatta; Mirjam Schweitzer-Martin; Aba Harcos; Sarah Schott; Hans Junkermann; Geraldine Rauch; Christof Sohn; Jörg Heil
Journal:  Eur J Radiol       Date:  2013-08-08       Impact factor: 3.528

5.  The evolution of breast imaging: past to present.

Authors:  Bonnie N Joe; Edward A Sickles
Journal:  Radiology       Date:  2014-11       Impact factor: 11.105

Review 6.  Breast elastography: the technical process and its applications.

Authors:  C Balleyguier; L Ciolovan; S Ammari; S Canale; S Sethom; R Al Rouhbane; P Vielh; C Dromain
Journal:  Diagn Interv Imaging       Date:  2013-04-22       Impact factor: 4.026

7.  Added value of shear-wave elastography for evaluation of breast masses detected with screening US imaging.

Authors:  Su Hyun Lee; Jung Min Chang; Won Hwa Kim; Min Sun Bae; Mirinae Seo; Hye Ryoung Koo; A Jung Chu; Hye Mi Gweon; Nariya Cho; Woo Kyung Moon
Journal:  Radiology       Date:  2014-06-19       Impact factor: 11.105

8.  Evaluation of breast lesions using sonographic elasticity imaging: a multicenter trial.

Authors:  Richard G Barr; Stamatia Destounis; Logan B Lackey; William E Svensson; Corinne Balleyguier; Carmel Smith
Journal:  J Ultrasound Med       Date:  2012-02       Impact factor: 2.153

9.  Cancer in the global health era: opportunities for the Middle East and Asia.

Authors:  Subhojit Dey; Amr S Soliman
Journal:  Asia Pac J Public Health       Date:  2010-07       Impact factor: 1.399

10.  A non-invasive modality: the US virtual touch tissue quantification (VTTQ) for evaluation of breast cancer.

Authors:  Kentaro Tamaki; Nobumitsu Tamaki; Yoshihiko Kamada; Kano Uehara; Minoru Miyashita; Takanori Ishida; Hironobu Sasano
Journal:  Jpn J Clin Oncol       Date:  2013-08-02       Impact factor: 3.019

View more
  16 in total

1.  Can strain elastography combined with ultrasound breast imaging reporting and data system be a more effective method in the differentiation of benign and malignant breast lesions?

Authors:  Serdar Arslan; Nihal Uslu; Funda Ulu Ozturk; Eda Yilmaz Akcay; Tugan Tezcaner; Ahmet Muhtesem Agildere
Journal:  J Med Ultrason (2001)       Date:  2017-02-02       Impact factor: 1.314

2.  Differentiating the acute phase of gout from the intercritical phase with ultrasound and quantitative shear wave elastography.

Authors:  Qiao Wang; Le-Hang Guo; Xiao-Long Li; Chong-Ke Zhao; Ming-Xu Li; Ling Wang; Xin-Ying Liu; Hui-Xiong Xu
Journal:  Eur Radiol       Date:  2018-06-04       Impact factor: 5.315

3.  The value of virtual touch tissue imaging quantification in the differential diagnosis between benign and malignant breast lesions.

Authors:  Wen-Tao Kong; Wei-Jun Zhou; Yin Wang; Xiao-Min Zhuang; Min Wu
Journal:  J Med Ultrason (2001)       Date:  2019-05-17       Impact factor: 1.314

4.  Quantitative Multiparametric Breast Ultrasound: Application of Contrast-Enhanced Ultrasound and Elastography Leads to an Improved Differentiation of Benign and Malignant Lesions.

Authors:  Panagiotis Kapetas; Paola Clauser; Ramona Woitek; Georg J Wengert; Mathias Lazar; Katja Pinker; Thomas H Helbich; Pascal A T Baltzer
Journal:  Invest Radiol       Date:  2019-05       Impact factor: 6.016

5.  Differential diagnosis of B-mode ultrasound Breast Imaging Reporting and Data System category 3-4a lesions in conjunction with shear-wave elastography using conservative and aggressive approaches.

Authors:  Wenxiang Zhi; Aiyu Miao; Chao You; Jin Zhou; Haixian Zhang; Xiaoli Zhu; Yu Wang; Cai Chang
Journal:  Quant Imaging Med Surg       Date:  2022-07

6.  Combining conventional ultrasound and sonoelastography to predict axillary status after neoadjuvant chemotherapy for breast cancer.

Authors:  Jia-Xin Huang; Shi-Yang Lin; Yan Ou; Cai-Gou Shi; Yuan Zhong; Ming-Jie Wei; Xiao-Qing Pei
Journal:  Eur Radiol       Date:  2022-04-02       Impact factor: 7.034

7.  Quality Measurement of Two-dimensional Shear Wave Speed Imaging for Breast Lesions: the Associated Factors and the Impact to Diagnostic Performance.

Authors:  Dan-Dan Li; Hui-Xiong Xu; Bo-Ji Liu; Xiao-Wan Bo; Xiao-Long Li; Rong Wu
Journal:  Sci Rep       Date:  2017-07-11       Impact factor: 4.379

8.  A Risk Model based on Ultrasound, Ultrasound Elastography, and Histologic Parameters for Predicting Axillary Lymph Node Metastasis in Breast Invasive Ductal Carcinoma.

Authors:  Xiao-Long Li; Hui-Xiong Xu; Dan-Dan Li; Ya-Ping He; Wen-Wen Yue; Jun-Mei Xu; Bo-Ji Liu; Li-Ping Sun; Lin Fang
Journal:  Sci Rep       Date:  2017-06-08       Impact factor: 4.379

9.  Virtual Touch IQ elastography reduces unnecessary breast biopsies by applying quantitative "rule-in" and "rule-out" threshold values.

Authors:  Panagiotis Kapetas; Paola Clauser; Ramona Woitek; Katja Pinker; Maria Bernathova; Thomas H Helbich; Pascal A Baltzer
Journal:  Sci Rep       Date:  2018-02-26       Impact factor: 4.379

10.  Value of shear wave arrival time contour display in shear wave elastography for breast masses diagnosis.

Authors:  Bang-Guo Zhou; Dan Wang; Wei-Wei Ren; Xiao-Long Li; Ya-Ping He; Bo-Ji Liu; Qiao Wang; Shi-Gao Chen; Azra Alizad; Hui-Xiong Xu
Journal:  Sci Rep       Date:  2017-08-01       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.