Literature DB >> 24955927

Added value of shear-wave elastography for evaluation of breast masses detected with screening US imaging.

Su Hyun Lee1, Jung Min Chang, Won Hwa Kim, Min Sun Bae, Mirinae Seo, Hye Ryoung Koo, A Jung Chu, Hye Mi Gweon, Nariya Cho, Woo Kyung Moon.   

Abstract

PURPOSE: To evaluate the additional value of shear-wave elastography (SWE) to B-mode ultrasonography (US) and to determine an appropriate guideline for the combined assessment of screening US-detected breast masses.
MATERIALS AND METHODS: This study was conducted with institutional review board approval, and written informed consent was obtained. From March 2010 to February 2012, B-mode US and SWE were performed in 159 US-detected breast masses before biopsy. For each lesion, Breast Imaging Reporting and Data System (BI-RADS) category on B-mode US images and the maximum stiffness color and elasticity values on SWE images were assessed. A guideline for adding SWE data to B-mode US was developed with the retrospective cohort to improve diagnostic performance in sensitivity and specificity and was validated in a distinct prospective cohort of 207 women prior to biopsy.
RESULTS: Twenty-one of 159 masses in the development cohort and 12 of 207 breast masses in the validation cohort were malignant. In the development cohort, when BI-RADS category 4a masses showing a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images were downgraded to category 3, specificity increased from 9.4% (13 of 138) to 59.4% (82 of 138) and 57.2% (79 of 138) (P < .001), respectively, without loss in sensitivity (100% [21 of 21]). In the validation cohort, specificity increased from 17.4% (34 of 195) to 62.1% (121 of 195) and 53.3% (104 of 195) (P < .001) respectively, without loss in sensitivity (91.7% [11 of 12]).
CONCLUSION: The addition of SWE to B-mode US improved diagnostic performance with increased specificity for screening US-detected breast masses. BI-RADS category 4a masses detected at US screening that showed a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images can be safely followed up instead of performing biopsy. © RSNA, 2014.

Entities:  

Mesh:

Year:  2014        PMID: 24955927     DOI: 10.1148/radiol.14132443

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  28 in total

1.  Combination of two-dimensional shear wave elastography with ultrasound breast imaging reporting and data system in the diagnosis of breast lesions: a new method to increase the diagnostic performance.

Authors:  Dan-Dan Li; Hui-Xiong Xu; Le-Hang Guo; Xiao-Wan Bo; Xiao-Long Li; Rong Wu; Jun-Mei Xu; Yi-Feng Zhang; Kun Zhang
Journal:  Eur Radiol       Date:  2015-12-29       Impact factor: 5.315

2.  Additional diagnostic value of shear-wave elastography and color Doppler US for evaluation of breast non-mass lesions detected at B-mode US.

Authors:  Ji Soo Choi; Boo-Kyung Han; Eun Young Ko; Eun Sook Ko; Jung Hee Shin; Ga Ram Kim
Journal:  Eur Radiol       Date:  2016-01-19       Impact factor: 5.315

3.  Diagnostic performance of shear wave elastography in discriminating malignant and benign breast lesions : Our experience with QelaXtoTM software.

Authors:  Karina Pesce; Fernando Binder; María José Chico; María Paz Swiecicki; Diana Herbas Galindo; Sergio Terrasa
Journal:  J Ultrasound       Date:  2020-06-11

4.  Shear wave elastography in the diagnosis of breast non-mass lesions: factors associated with false negative and false positive results.

Authors:  So Yoon Park; Ji Soo Choi; Boo-Kyung Han; Eun Young Ko; Eun Sook Ko
Journal:  Eur Radiol       Date:  2017-02-06       Impact factor: 5.315

5.  Building an open-source simulation platform of acoustic radiation force-based breast elastography.

Authors:  Yu Wang; Bo Peng; Jingfeng Jiang
Journal:  Phys Med Biol       Date:  2017-01-11       Impact factor: 3.609

6.  Can shear wave elastography be utilized as an additional tool for the assessment of non-mass breast lesions?

Authors:  Sepideh Sefidbakht; Sara Haseli; Neda Khalili; Vahid Bazojoo; Pedram Keshavarz; Banafsheh Zeinali-Rafsanjani
Journal:  Ultrasound       Date:  2021-03-17

7.  Tumor stiffness measured by shear-wave elastography: association with disease-free survival in women with early-stage breast cancer.

Authors:  Jin You Kim; Jin Joo Kim; Lee Hwangbo; Hie Bum Suh; Ji Won Lee; Nam Kyung Lee; Ki Seok Choo; Suk Kim
Journal:  Br J Radiol       Date:  2021-10-05       Impact factor: 3.039

8.  Diagnostic performance of qualitative and quantitative shear wave elastography in differentiating malignant from benign breast masses, and association with the histological prognostic factors.

Authors:  Voraparee Suvannarerg; Piyanuch Chitchumnong; Wipawan Apiwat; Lassanun Lertdamrongdej; Nattinee Tretipwanit; Pongthep Pisarnturakit; Panitta Sitthinamsuwan; Shanigarn Thiravit; Kobkun Muangsomboon; Pornpim Korpraphong
Journal:  Quant Imaging Med Surg       Date:  2019-03

9.  Shear wave elastography for the diagnosis of small (≤2 cm) breast lesions: added value and factors associated with false results.

Authors:  Hye Young Choi; Mirinae Seo; Yu-Mee Sohn; Ji Hye Hwang; Eun Jee Song; Sun Young Min; Hye Jin Kang; Dong Yoon Han
Journal:  Br J Radiol       Date:  2019-03-26       Impact factor: 3.039

10.  The significance of dual-mode elastography in the diagnosis of breast lesions by physicians with different levels of experience.

Authors:  Sijing Huang; Xiuqin Ye; Keen Yang; Hongtian Tian; Zhimin Ding; Jing Chen; Jinfeng Xu; Fajin Dong
Journal:  Quant Imaging Med Surg       Date:  2022-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.