Literature DB >> 26682167

Comparison of 45-degree Kelman and 45-degree balanced phaco tip designs in torsional microcoaxial phacoemulsification.

Süleyman Demircan1, Mustafa Ataş1, Emre Göktaş1, Burhan Başkan1.   

Abstract

AIM: To compare the intraoperative performance and postoperative outcome after microcoaxial torsional phacoemulsification using either a Kelman or balanced phaco tip.
METHODS: Cataracts were treated using 2.2 mm microcoaxial torsional phacoemulsification using either a 45-degree mini-flared Kelman(®) or a 45-degree Intrepid(®) Balanced phaco tip. Intraoperative measurements included total ultrasound (US) time, cumulative dissipated energy (CDE), torsional US time, and balanced salt solution (BSS) use. The central endothelial cell density (ECD) and central corneal thickness (CCT) were evaluated preoperatively and postoperatively 1, 7, and 30d after surgery using noncontact specular microscopy.
RESULTS: The 116 enrolled eyes (116 patients) were divided equally between the Kelman and balanced tip groups. Intraoperative measurements showed significantly less total US time, torsional US time, CDE, and BSS use in the balanced group than in Kelman group (P<0.05). The total US time, torsional US time, CDE, and BSS use were 17.45±14.53s, 16.63±13.97s, 6.38±5.26, and 48.21±17.21 mL in the Kelman group and 11.39 ± 9.60s, 10.90 ± 9.25s, 4.04 ± 3.42, and 41.36 ± 12.70 mL in the balanced group, respectively.
CONCLUSION: Torsional phacoemulsification performed with a balanced tip provided more effective lens removal with less total US time, torsional time, CDE, and BSS use, as well as similar changes in ECD with a Kelman tip in all cataract grades. This special designed phaco tip for torsional phacoemulsification provides an alternative phaco tip for many surgeons' preference with straight phaco tip.

Entities:  

Keywords:  Kelman phaco tip; balanced phaco tip; phaco tip; torsional phacoemulsification

Year:  2015        PMID: 26682167      PMCID: PMC4651883          DOI: 10.3980/j.issn.2222-3959.2015.06.16

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  17 in total

1.  Clinical application of a Scheimpflug system for lens density measurements in phacoemulsification.

Authors:  Jung-Sub Kim; So-Hyang Chung; Choun-Ki Joo
Journal:  J Cataract Refract Surg       Date:  2009-07       Impact factor: 3.351

2.  Combined occlusion-triggered longitudinal and torsional phacoemulsification during coaxial microincision cataract surgery: effect on 30-degree mini-flared tip behavior.

Authors:  Gokulan Ratnarajan; Richard Packard; Mina Ward
Journal:  J Cataract Refract Surg       Date:  2011-03-25       Impact factor: 3.351

3.  Comparison of tips in coaxial microincision cataract surgery with the bevel-down technique.

Authors:  Eun Kyoung Kim; Kyong Jin Jo; Choun-Ki Joo
Journal:  J Cataract Refract Surg       Date:  2011-09-09       Impact factor: 3.351

4.  New phacoemulsification tip with a grooved, threaded-tip construction.

Authors:  Akinari Watanabe
Journal:  J Cataract Refract Surg       Date:  2011-05-20       Impact factor: 3.351

5.  Comparison of corneal endothelial changes following phacoemulsification with transversal and torsional phacoemulsification machines.

Authors:  Mustafa Ataş; Süleyman Demircan; Arzu Seyhan Karatepe Haşhaş; Ahmet Gülhan; Gökmen Zararsız
Journal:  Int J Ophthalmol       Date:  2014-10-18       Impact factor: 1.779

6.  Emulsification action of longitudinal and torsional ultrasound tips and the effect on treatment of the nucleus during phacoemulsification.

Authors:  Teruyuki Miyoshi; Hironori Yoshida
Journal:  J Cataract Refract Surg       Date:  2010-07       Impact factor: 3.351

7.  Comparison of two different ultrasound methods of phacoemulsification.

Authors:  Firat Helvacioglu; Celal Yeter; Sadik Sencan; Zeki Tunc; O Murat Uyar
Journal:  Am J Ophthalmol       Date:  2014-04-30       Impact factor: 5.258

8.  Length and frequency of intraoperative occlusive events with new torsional phacoemulsification software.

Authors:  Robert J Cionni; Alan S Crandall; David Felsted
Journal:  J Cataract Refract Surg       Date:  2011-08-19       Impact factor: 3.351

9.  The Impact of Reused Phaco Tip on Outcomes of Phacoemulsification Surgery.

Authors:  Suleyman Demircan; Gokcen Gokce; Mustafa Atas; Burhan Baskan; Emre Goktas; Gokmen Zararsiz
Journal:  Curr Eye Res       Date:  2015-04-16       Impact factor: 2.424

10.  Comparative analysis of the nuclear lens opalescence by the Lens Opacities Classification System III with nuclear density values provided by Oculus Pentacam: a cross-section study using Pentacam Nucleus Staging software.

Authors:  Fernanda Pedreira Magalhães; Elaine Fiod Costa; Angelino Júlio Cariello; Eduardo Buchele Rodrigues; Ana Luisa Hofling-Lima
Journal:  Arq Bras Oftalmol       Date:  2011 Mar-Apr       Impact factor: 0.872

View more
  7 in total

1.  Prospective study of Centurion® versus Infiniti® phacoemulsification systems: surgical and visual outcomes.

Authors:  Lawrence J Oh; Chu Luan Nguyen; Eugene Wong; Samuel S Y Wang; Ian C Francis
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

2.  Comment on "Comparison of 45-degree Kelman and 45-degree balanced phaco tip designs in torsional microcoaxial phacoemulsification".

Authors:  Neelima Aron; Sagnik Sen; Sudarshan Khokhar
Journal:  Int J Ophthalmol       Date:  2017-08-18       Impact factor: 1.779

3.  Efficacy of Balanced Torsional Phacoemulsification Tip for Cataract Surgery.

Authors:  Huri Sabur; Sayime Aydin Eroglu; Salih Sertac Azarsiz
Journal:  J Curr Ophthalmol       Date:  2022-04-16

4.  Effect of IOP based infusion system with and without balanced phaco tip on cumulative dissipated energy and estimated fluid usage in comparison to gravity fed infusion in torsional phacoemulsification.

Authors:  Praveen K Malik; Taru Dewan; Arun Kr Patidar; Ekta Sain
Journal:  Eye Vis (Lond)       Date:  2017-09-17

5.  Active-fluidics-based torsional phacoemulsification in diabetic eyes: A prospective interventional study.

Authors:  Sudarshan Khokhar; Sagnik Sen; Chirakshi Dhull
Journal:  Indian J Ophthalmol       Date:  2019-05       Impact factor: 1.848

6.  Comparisons of the energy efficiency and intraocular safety of two torsional phacoemulsification tips.

Authors:  Yan-Xiu Sun; Rong Cao; Zi-Yuan Liu; Hua-Qin Xia; Yu-Jie Cen; Lu Gao; Dan-Dan Shi
Journal:  BMC Ophthalmol       Date:  2022-10-03       Impact factor: 2.086

7.  Comparative studies between longitudinal and torsional modes in phacoemulsification, using active fluidics technology along with the intrepid balanced tip.

Authors:  Sushobhan Dasgupta; Rohan Mehra
Journal:  Indian J Ophthalmol       Date:  2018-10       Impact factor: 1.848

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.