Literature DB >> 26308155

Does fat suppression via chemically selective saturation affect R2*-MRI for transfusional iron overload assessment? A clinical evaluation at 1.5T and 3T.

Axel J Krafft1, Ralf B Loeffler1, Ruitian Song1, Xiao Bian1,2, M Beth McCarville1, Jane S Hankins3, Claudia M Hillenbrand1.   

Abstract

PURPOSE: Fat suppression (FS) via chemically selective saturation (CHESS) eliminates fat-water oscillations in multiecho gradient echo (mGRE) R2*-MRI. However, for increasing R2* values as seen with increasing liver iron content (LIC), the water signal spectrally overlaps with the CHESS band, which may alter R2*. We investigated the effect of CHESS on R2* and developed a heuristic correction for the observed CHESS-induced R2* changes.
METHODS: Eighty patients [female, n = 49; male, n = 31; mean age (± standard deviation), 18.3 ± 11.7 y] with iron overload were scanned with a non-FS and a CHESS-FS mGRE sequence at 1.5T and 3T. Mean liver R2* values were evaluated using three published fitting approaches. Measured and model-corrected R2* values were compared and statistically analyzed.
RESULTS: At 1.5T, CHESS led to a systematic R2* reduction (P < 0.001 for all fitting algorithms) especially toward higher R2*. Our model described the observed changes well and reduced the CHESS-induced R2* bias after correction (linear regression slopes: 1.032/0.927/0.981). No CHESS-induced R2* reductions were found at 3T.
CONCLUSION: The CHESS-induced R2* bias at 1.5T needs to be considered when applying R2*-LIC biopsy calibrations for clinical LIC assessment, which were established without FS at 1.5T. The proposed model corrects the R2* bias and could therefore improve clinical iron overload assessment based on linear R2*-LIC calibrations. Magn Reson Med 76:591-601, 2016.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  R2* quantification; fat suppression (CHESS); hepatic iron overload; liver MRI; quantitative MRI

Mesh:

Year:  2015        PMID: 26308155      PMCID: PMC4769126          DOI: 10.1002/mrm.25868

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  54 in total

1.  Consequences of T2 relaxation during half-pulse slice selection for ultrashort TE imaging.

Authors:  Matthew D Robson; Peter D Gatehouse
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

2.  Comparison of whole liver and small region-of-interest measurements of MRI liver R2* in children with iron overload.

Authors:  M Beth McCarville; Claudia M Hillenbrand; Ralf B Loeffler; Matthew P Smeltzer; Ruitan Song; Chin-Shang Li; Jane S Hankins
Journal:  Pediatr Radiol       Date:  2010-03-24

3.  Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging.

Authors:  Scott B Reeder; Angel R Pineda; Zhifei Wen; Ann Shimakawa; Huanzhou Yu; Jean H Brittain; Garry E Gold; Christopher H Beaulieu; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

4.  Relaxation effects in the quantification of fat using gradient echo imaging.

Authors:  Mark Bydder; Takeshi Yokoo; Gavin Hamilton; Michael S Middleton; Alyssa D Chavez; Jeffrey B Schwimmer; Joel E Lavine; Claude B Sirlin
Journal:  Magn Reson Imaging       Date:  2008-02-21       Impact factor: 2.546

5.  Magnetic susceptibility as a B0 field strength independent MRI biomarker of liver iron overload.

Authors:  Diego Hernando; Rachel J Cook; Carol Diamond; Scott B Reeder
Journal:  Magn Reson Med       Date:  2013-06-25       Impact factor: 4.668

6.  1H NMR chemical shift selective (CHESS) imaging.

Authors:  A Haase; J Frahm; W Hänicke; D Matthaei
Journal:  Phys Med Biol       Date:  1985-04       Impact factor: 3.609

7.  The use of appropriate calibration curves corrects for systematic differences in liver R2* values measured using different software packages.

Authors:  Antonella Meloni; Hugh Y Rienhoff; Amber Jones; Alessia Pepe; Massimo Lombardi; John C Wood
Journal:  Br J Haematol       Date:  2013-03-18       Impact factor: 6.998

8.  Relaxivity-iron calibration in hepatic iron overload: Predictions of a Monte Carlo model.

Authors:  Nilesh R Ghugre; Eamon K Doyle; Pippa Storey; John C Wood
Journal:  Magn Reson Med       Date:  2014-09-19       Impact factor: 4.668

9.  Comparison between multi-echo T2* with and without fat saturation pulse for quantification of liver iron overload.

Authors:  Liana Sanches-Rocha; Bruna Serpa; Eduardo Figueiredo; Nelson Hamerschlak; Ronaldo Baroni
Journal:  Magn Reson Imaging       Date:  2013-08-24       Impact factor: 2.546

10.  Improved MRI R2 * relaxometry of iron-loaded liver with noise correction.

Authors:  Yanqiu Feng; Taigang He; Peter D Gatehouse; Xinzhong Li; Mohammed Harith Alam; Dudley J Pennell; Wufan Chen; David N Firmin
Journal:  Magn Reson Med       Date:  2013-01-28       Impact factor: 4.668

View more
  13 in total

1.  Automated vessel exclusion technique for quantitative assessment of hepatic iron overload by R2*-MRI.

Authors:  Aaryani Tipirneni-Sajja; Ruitian Song; M Beth McCarville; Ralf B Loeffler; Jane S Hankins; Claudia M Hillenbrand
Journal:  J Magn Reson Imaging       Date:  2017-10-30       Impact factor: 4.813

2.  Radial Ultrashort TE Imaging Removes the Need for Breath-Holding in Hepatic Iron Overload Quantification by R2* MRI.

Authors:  Aaryani Tipirneni-Sajja; Axel J Krafft; M Beth McCarville; Ralf B Loeffler; Ruitian Song; Jane S Hankins; Claudia M Hillenbrand
Journal:  AJR Am J Roentgenol       Date:  2017-05-15       Impact factor: 3.959

3.  Autoregressive moving average modeling for hepatic iron quantification in the presence of fat.

Authors:  Aaryani Tipirneni-Sajja; Axel J Krafft; Ralf B Loeffler; Ruitian Song; Armita Bahrami; Jane S Hankins; Claudia M Hillenbrand
Journal:  J Magn Reson Imaging       Date:  2019-02-13       Impact factor: 4.813

4.  Quantitative ultrashort echo time imaging for assessment of massive iron overload at 1.5 and 3 Tesla.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Aaryani Tipirneni-Sajja; M Beth McCarville; Matthew D Robson; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2017-01-16       Impact factor: 4.668

Review 5.  Magnetic Resonanance Imaging of the Liver (Including Biliary Contrast Agents)-Part 2: Protocols for Liver Magnetic Resonanance Imaging and Characterization of Common Focal Liver Lesions.

Authors:  Andrea Agostini; Moritz F Kircher; Richard K G Do; Alessandra Borgheresi; Serena Monti; Andrea Giovagnoni; Lorenzo Mannelli
Journal:  Semin Roentgenol       Date:  2016-05-30       Impact factor: 0.800

6.  Quantitative susceptibility mapping (QSM) minimizes interference from cellular pathology in R2* estimation of liver iron concentration.

Authors:  Jianqi Li; Huimin Lin; Tian Liu; Zhuwei Zhang; Martin R Prince; Kelly Gillen; Xu Yan; Qi Song; Ting Hua; Xiance Zhao; Miao Zhang; Yu Zhao; Gaiying Li; Guangyu Tang; Guang Yang; Gary M Brittenham; Yi Wang
Journal:  J Magn Reson Imaging       Date:  2018-03-22       Impact factor: 4.813

7.  Can multi-slice or navigator-gated R2* MRI replace single-slice breath-hold acquisition for hepatic iron quantification?

Authors:  Ralf B Loeffler; M Beth McCarville; Anne W Wagstaff; Matthew P Smeltzer; Axel J Krafft; Ruitian Song; Jane S Hankins; Claudia M Hillenbrand
Journal:  Pediatr Radiol       Date:  2016-10-17

8.  Ultrashort echo time imaging for quantification of hepatic iron overload: Comparison of acquisition and fitting methods via simulations, phantoms, and in vivo data.

Authors:  Aaryani Tipirneni-Sajja; Ralf B Loeffler; Axel J Krafft; Andrea N Sajewski; Robert J Ogg; Jane S Hankins; Claudia M Hillenbrand
Journal:  J Magn Reson Imaging       Date:  2018-10-25       Impact factor: 4.813

9.  Quantitative susceptibility mapping in combination with water-fat separation for simultaneous liver iron and fat fraction quantification.

Authors:  Huimin Lin; Hongjiang Wei; Naying He; Caixia Fu; Shu Cheng; Jun Shen; Baisong Wang; Xu Yan; Chunlei Liu; Fuhua Yan
Journal:  Eur Radiol       Date:  2018-02-22       Impact factor: 5.315

10.  Quantification of pancreatic iron overload and fat infiltration and their correlation with glucose disturbance in pediatric thalassemia major patients.

Authors:  Jingwen Huang; Jun Shen; Qihua Yang; Ziliang Cheng; Xiaodong Chen; Taihui Yu; Jinglian Zhong; Yun Su; Hua Guo; Biling Liang
Journal:  Quant Imaging Med Surg       Date:  2021-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.