PURPOSE: Fat suppression (FS) via chemically selective saturation (CHESS) eliminates fat-water oscillations in multiecho gradient echo (mGRE) R2*-MRI. However, for increasing R2* values as seen with increasing liver iron content (LIC), the water signal spectrally overlaps with the CHESS band, which may alter R2*. We investigated the effect of CHESS on R2* and developed a heuristic correction for the observed CHESS-induced R2* changes. METHODS: Eighty patients [female, n = 49; male, n = 31; mean age (± standard deviation), 18.3 ± 11.7 y] with iron overload were scanned with a non-FS and a CHESS-FS mGRE sequence at 1.5T and 3T. Mean liver R2* values were evaluated using three published fitting approaches. Measured and model-corrected R2* values were compared and statistically analyzed. RESULTS: At 1.5T, CHESS led to a systematic R2* reduction (P < 0.001 for all fitting algorithms) especially toward higher R2*. Our model described the observed changes well and reduced the CHESS-induced R2* bias after correction (linear regression slopes: 1.032/0.927/0.981). No CHESS-induced R2* reductions were found at 3T. CONCLUSION: The CHESS-induced R2* bias at 1.5T needs to be considered when applying R2*-LIC biopsy calibrations for clinical LIC assessment, which were established without FS at 1.5T. The proposed model corrects the R2* bias and could therefore improve clinical iron overload assessment based on linear R2*-LIC calibrations. Magn Reson Med 76:591-601, 2016.
PURPOSE:Fat suppression (FS) via chemically selective saturation (CHESS) eliminates fat-water oscillations in multiecho gradient echo (mGRE) R2*-MRI. However, for increasing R2* values as seen with increasing liver iron content (LIC), the water signal spectrally overlaps with the CHESS band, which may alter R2*. We investigated the effect of CHESS on R2* and developed a heuristic correction for the observed CHESS-induced R2* changes. METHODS: Eighty patients [female, n = 49; male, n = 31; mean age (± standard deviation), 18.3 ± 11.7 y] with iron overload were scanned with a non-FS and a CHESS-FS mGRE sequence at 1.5T and 3T. Mean liver R2* values were evaluated using three published fitting approaches. Measured and model-corrected R2* values were compared and statistically analyzed. RESULTS: At 1.5T, CHESS led to a systematic R2* reduction (P < 0.001 for all fitting algorithms) especially toward higher R2*. Our model described the observed changes well and reduced the CHESS-induced R2* bias after correction (linear regression slopes: 1.032/0.927/0.981). No CHESS-induced R2* reductions were found at 3T. CONCLUSION: The CHESS-induced R2* bias at 1.5T needs to be considered when applying R2*-LIC biopsy calibrations for clinical LIC assessment, which were established without FS at 1.5T. The proposed model corrects the R2* bias and could therefore improve clinical iron overload assessment based on linear R2*-LIC calibrations. Magn Reson Med 76:591-601, 2016.
Authors: M Beth McCarville; Claudia M Hillenbrand; Ralf B Loeffler; Matthew P Smeltzer; Ruitan Song; Chin-Shang Li; Jane S Hankins Journal: Pediatr Radiol Date: 2010-03-24
Authors: Scott B Reeder; Angel R Pineda; Zhifei Wen; Ann Shimakawa; Huanzhou Yu; Jean H Brittain; Garry E Gold; Christopher H Beaulieu; Norbert J Pelc Journal: Magn Reson Med Date: 2005-09 Impact factor: 4.668
Authors: Mark Bydder; Takeshi Yokoo; Gavin Hamilton; Michael S Middleton; Alyssa D Chavez; Jeffrey B Schwimmer; Joel E Lavine; Claude B Sirlin Journal: Magn Reson Imaging Date: 2008-02-21 Impact factor: 2.546
Authors: Yanqiu Feng; Taigang He; Peter D Gatehouse; Xinzhong Li; Mohammed Harith Alam; Dudley J Pennell; Wufan Chen; David N Firmin Journal: Magn Reson Med Date: 2013-01-28 Impact factor: 4.668
Authors: Aaryani Tipirneni-Sajja; Axel J Krafft; M Beth McCarville; Ralf B Loeffler; Ruitian Song; Jane S Hankins; Claudia M Hillenbrand Journal: AJR Am J Roentgenol Date: 2017-05-15 Impact factor: 3.959
Authors: Axel J Krafft; Ralf B Loeffler; Ruitian Song; Aaryani Tipirneni-Sajja; M Beth McCarville; Matthew D Robson; Jane S Hankins; Claudia M Hillenbrand Journal: Magn Reson Med Date: 2017-01-16 Impact factor: 4.668
Authors: Andrea Agostini; Moritz F Kircher; Richard K G Do; Alessandra Borgheresi; Serena Monti; Andrea Giovagnoni; Lorenzo Mannelli Journal: Semin Roentgenol Date: 2016-05-30 Impact factor: 0.800
Authors: Ralf B Loeffler; M Beth McCarville; Anne W Wagstaff; Matthew P Smeltzer; Axel J Krafft; Ruitian Song; Jane S Hankins; Claudia M Hillenbrand Journal: Pediatr Radiol Date: 2016-10-17
Authors: Aaryani Tipirneni-Sajja; Ralf B Loeffler; Axel J Krafft; Andrea N Sajewski; Robert J Ogg; Jane S Hankins; Claudia M Hillenbrand Journal: J Magn Reson Imaging Date: 2018-10-25 Impact factor: 4.813