Consequences of T2 relaxation during half-pulse slice selection for ultrashort TE imaging.

Matthew D Robson1, Peter D Gatehouse.   

Abstract

A "half-pulse" slice selection approach is used in the ultrashort echo time pulse sequence and is required to give minimal transverse relaxation in a two-dimensional acquisition. This method splits the normal excitation radiofrequency pulse in half and acquires a pair of images, each using one of these half-pulses. These half-pulses are used without a refocusing gradient since summing the pair of images yields images with accurate slice selection. When the radiofrequency pulse duration is similar to the sample T(2), characteristics such as the effective echo time and choice of radiofrequency pulse require careful evaluation as some of the approximations in conventional slice selection do not apply. We derive a theory that includes relaxation during excitation using Pauly's excitation k-space formalism. Further, this theory is tested on phantoms with a range of values of T(2) demonstrating the effect on the slice profile. We conclude that relaxation during excitation is significant and should be included in our estimate of the T(2) weighting of the sequence. In general, the T(2) weighting should be measured from the time of the centroid of the excitation pulse.

Mesh:

Year:  2010        PMID: 20665804     DOI: 10.1002/mrm.22323

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  9 in total

1.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  Maximizing MR signal for 2D UTE slice selection in the presence of rapid transverse relaxation.

Authors:  Michael Carl; Jing-Tzyh Alan Chiang; Jiang Du
Journal:  Magn Reson Imaging       Date:  2014-05-09       Impact factor: 2.546

3.  Quantitative MRI measurements of the Achilles tendon in spondyloarthritis using ultrashort echo times.

Authors:  R J Hodgson; N Menon; A J Grainger; P J O'Connor; D McGonagle; P Helliwell; P Emery; M D Robson
Journal:  Br J Radiol       Date:  2012-07       Impact factor: 3.039

4.  30-Second bound and pore water concentration mapping of cortical bone using 2D UTE with optimized half-pulses.

Authors:  Mary Kate Manhard; Kevin D Harkins; Daniel F Gochberg; Jeffry S Nyman; Mark D Does
Journal:  Magn Reson Med       Date:  2017-01-16       Impact factor: 4.668

5.  Simple and robust saturation-based slice selection for ultrashort echo time MRI.

Authors:  Kevin D Harkins; R Adam Horch; Mark D Does
Journal:  Magn Reson Med       Date:  2014-07-09       Impact factor: 4.668

6.  Optimized 3D ultrashort echo time pulmonary MRI.

Authors:  Kevin M Johnson; Sean B Fain; Mark L Schiebler; Scott Nagle
Journal:  Magn Reson Med       Date:  2012-12-04       Impact factor: 4.668

7.  Validation of quantitative bound- and pore-water imaging in cortical bone.

Authors:  Mary Kate Manhard; R Adam Horch; Kevin D Harkins; Daniel F Gochberg; Jeffry S Nyman; Mark D Does
Journal:  Magn Reson Med       Date:  2013-07-22       Impact factor: 4.668

8.  Does fat suppression via chemically selective saturation affect R2*-MRI for transfusional iron overload assessment? A clinical evaluation at 1.5T and 3T.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Xiao Bian; M Beth McCarville; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

9.  Cardiac-respiratory self-gated cine ultra-short echo time (UTE) cardiovascular magnetic resonance for assessment of functional cardiac parameters at high magnetic fields.

Authors:  Verena Hoerr; Nina Nagelmann; Arno Nauerth; Michael T Kuhlmann; Jörg Stypmann; Cornelius Faber
Journal:  J Cardiovasc Magn Reson       Date:  2013-07-04       Impact factor: 5.364

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.