Literature DB >> 23978552

Comparison between multi-echo T2* with and without fat saturation pulse for quantification of liver iron overload.

Liana Sanches-Rocha1, Bruna Serpa, Eduardo Figueiredo, Nelson Hamerschlak, Ronaldo Baroni.   

Abstract

PURPOSE: To test a magnetic resonance image (MRI) technique that uses an additional pulse in multi-echo T2* sequence that works to suppress the fat signal, in subjects with liver iron overload and concomitant presence of fat in the liver, which have been revealed as a major drawback that compromises the correct iron quantification by MRI.
MATERIALS AND METHODS: Fifty magnetic resonance images of the liver (1.5T scanner) of individuals with blood ferritin increases were retrospectively reviewed for the presence of steatosis, using the sequence in and out of phase, and iron overloading, using two sequences T2 * multi-echo: one standard and other with additional fat suppression pulse. T2 * values and their standard deviations were analyzed statistically.
RESULTS: Our results showed that a significantly lower standard deviation of T2* values is obtained when the fat saturation pulse is applied in patients with steatosis. We found that modulation of fat signal on liver iron overload resulted in a different categorization of some patients. In one case, the patient was re-classified within normal levels of liver iron.
CONCLUSION: Our findings may contribute to a better measure of liver iron overload with relevant implications for patient treatment and care.
© 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Fatty liver; Iron overload; Magnetic resonance imaging

Mesh:

Year:  2013        PMID: 23978552     DOI: 10.1016/j.mri.2013.07.013

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  5 in total

1.  Does fat suppression via chemically selective saturation affect R2*-MRI for transfusional iron overload assessment? A clinical evaluation at 1.5T and 3T.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Xiao Bian; M Beth McCarville; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

2.  Quantitative susceptibility mapping in combination with water-fat separation for simultaneous liver iron and fat fraction quantification.

Authors:  Huimin Lin; Hongjiang Wei; Naying He; Caixia Fu; Shu Cheng; Jun Shen; Baisong Wang; Xu Yan; Chunlei Liu; Fuhua Yan
Journal:  Eur Radiol       Date:  2018-02-22       Impact factor: 5.315

3.  The application value of ultra-short echo time MRI in the quantification of liver iron overload in a rat model.

Authors:  Qiaoling Wu; Xiuwei Fu; Zhizheng Zhuo; Mingfeng Zhao; Hongyan Ni
Journal:  Quant Imaging Med Surg       Date:  2019-02

4.  Liver Lobe Based Multi-Echo Gradient Recalled Echo T2*-Weighted Imaging in Chronic Hepatitis B-Related Cirrhosis: Association with the Presence and Child-Pugh Class of Cirrhosis.

Authors:  Dan Wang; Tian-Wu Chen; Xiao-Ming Zhang; Jie Li; Nan-Lin Zeng; Li Li; Yu-Lian Tang; Yu-Cheng Huang; Rui Li; Fan Chen; Yan-Li Chen
Journal:  PLoS One       Date:  2016-05-12       Impact factor: 3.240

5.  Validation of a new T2* algorithm and its uncertainty value for cardiac and liver iron load determination from MRI magnitude images.

Authors:  Sebastian Bidhult; Christos G Xanthis; Love Lindau Liljekvist; Gerald Greil; Eike Nagel; Anthony H Aletras; Einar Heiberg; Erik Hedström
Journal:  Magn Reson Med       Date:  2015-05-22       Impact factor: 4.668

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.