Literature DB >> 25242237

Relaxivity-iron calibration in hepatic iron overload: Predictions of a Monte Carlo model.

Nilesh R Ghugre1,2, Eamon K Doyle3, Pippa Storey4, John C Wood5.   

Abstract

PURPOSE: R2* (1/T2*) and single echo R2 (1/T2) have been calibrated to liver iron concentration (LIC) in patients with thalassemia and transfusion-dependent sickle cell disease at 1.5T. The R2*-LIC relationship is linear, whereas that of R2 is curvilinear. However, the increasing popularity of high-field scanners requires generalizing these relationships to higher field strengths. In this study, we tested the hypothesis that numerical simulation can accurately determine the field dependence of iron-mediated transverse relaxation rates.
METHODS: We previously replicated the calibration curves between R2 and R2* and iron at 1.5T using Monte Carlo models incorporating realistic liver structure, iron deposit susceptibility, and proton mobility. In this paper, we extend our model to predict relaxivity-iron calibrations at higher field strengths. Predictions were validated by measuring R2 and R2* at 1.5T and 3T in six β-thalassemia major patients.
RESULTS: Predicted R2* increased twofold at 3T from 1.5T, whereas R2 increased by a factor of 1.47. Patient data exhibited a coefficient of variation of 3.6% and 7.2%, respectively, to the best-fit simulated data. Simulations over the range 0.25T-7T showed R2* increasing linearly with field strength, whereas R2 exhibited a concave-downward relationship.
CONCLUSION: A model-based approach predicts alterations in relaxivity-iron calibrations with field strength without repeating imaging studies. The model may generalize to alternative pulse sequences and tissue iron distribution.
© 2014 Wiley Periodicals, Inc.

Entities:  

Keywords:  3T; Monte Carlo; high field; iron; liver; relaxation; relaxivity

Mesh:

Substances:

Year:  2014        PMID: 25242237      PMCID: PMC4951155          DOI: 10.1002/mrm.25459

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Feasibility, reproducibility, and reliability for the T*2 iron evaluation at 3 T in comparison with 1.5 T.

Authors:  Antonella Meloni; Vincenzo Positano; Petra Keilberg; Daniele De Marchi; Pasquale Pepe; Angelo Zuccarelli; Saveria Campisi; Maria Antonietta Romeo; Tommaso Casini; Pier Paolo Bitti; Calogera Gerardi; Maria Eliana Lai; Basilia Piraino; Gaetano Giuffrida; Giuseppina Secchi; Massimo Midiri; Massimo Lombardi; Alessia Pepe
Journal:  Magn Reson Med       Date:  2011-11-29       Impact factor: 4.668

2.  R2* imaging of transfusional iron burden at 3T and comparison with 1.5T.

Authors:  Pippa Storey; Alexis A Thompson; Christine L Carqueville; John C Wood; R Andrew de Freitas; Cynthia K Rigsby
Journal:  J Magn Reson Imaging       Date:  2007-03       Impact factor: 4.813

3.  Hepatic hemosiderosis in non-human primates: quantification of liver iron using different field strengths.

Authors:  J W Bulte; G F Miller; J Vymazal; R A Brooks; J A Frank
Journal:  Magn Reson Med       Date:  1997-04       Impact factor: 4.668

4.  Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging.

Authors:  I Yamada; W Aung; Y Himeno; T Nakagawa; H Shibuya
Journal:  Radiology       Date:  1999-03       Impact factor: 11.105

5.  Mechanisms of tissue-iron relaxivity: nuclear magnetic resonance studies of human liver biopsy specimens.

Authors:  Nilesh R Ghugre; Thomas D Coates; Marvin D Nelson; John C Wood
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

6.  A method for measurement of liver iron fractions in needle biopsy specimens and some results in acute liver disease.

Authors:  F M Zuyderhoudt; P Hengeveld; J van Gool; G G Jörning
Journal:  Clin Chim Acta       Date:  1978-06-15       Impact factor: 3.786

7.  Differential diagnosis between malignant and benign hepatic tumors using apparent diffusion coefficient on 1.5-T MR imaging: a meta analysis.

Authors:  Youwei Li; Zhengguang Chen; Jichen Wang
Journal:  Eur J Radiol       Date:  2011-02-18       Impact factor: 3.528

8.  Myocardial T2 quantitation in patients with iron overload at 3 Tesla.

Authors:  Hua Guo; Wing-Yan Au; Jerry S Cheung; Daniel Kim; Jens H Jensen; Pek-Lan Khong; Queenie Chan; Kevin C Chan; Christina Tosti; Haiying Tang; Truman R Brown; Wynnie W M Lam; Shau-Yin Ha; Gary M Brittenham; Ed X Wu
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

9.  Patterns of hepatic iron distribution in patients with chronically transfused thalassemia and sickle cell disease.

Authors:  Nilesh R Ghugre; Ignacio Gonzalez-Gomez; Ellen Butensky; Leila Noetzli; Roland Fischer; Roger Williams; Paul Harmatz; Thomas D Coates; John C Wood
Journal:  Am J Hematol       Date:  2009-08       Impact factor: 10.047

10.  Magnetic resonance imaging of the liver with ultrashort TE (UTE) pulse sequences.

Authors:  Karyn E Chappell; Nayna Patel; Peter D Gatehouse; Janice Main; Basant K Puri; Simon D Taylor-Robinson; Graeme M Bydder
Journal:  J Magn Reson Imaging       Date:  2003-12       Impact factor: 4.813

View more
  13 in total

1.  Quantification of liver fat in the presence of iron overload.

Authors:  Debra E Horng; Diego Hernando; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2016-07-13       Impact factor: 4.813

2.  Quantitative ultrashort echo time imaging for assessment of massive iron overload at 1.5 and 3 Tesla.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Aaryani Tipirneni-Sajja; M Beth McCarville; Matthew D Robson; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2017-01-16       Impact factor: 4.668

Review 3.  Topics on quantitative liver magnetic resonance imaging.

Authors:  Yì Xiáng J Wáng; Xiaoqi Wang; Peng Wu; Yajie Wang; Weibo Chen; Huijun Chen; Jianqi Li
Journal:  Quant Imaging Med Surg       Date:  2019-11

4.  Assessment of liver iron overload by 3 T MRI.

Authors:  A Paisant; A Boulic; E Bardou-Jacquet; E Bannier; G d'Assignies; F Lainé; B Turlin; Y Gandon
Journal:  Abdom Radiol (NY)       Date:  2017-06

5.  Ultra-short echo time images quantify high liver iron.

Authors:  Eamon K Doyle; Kristin Toy; Bertin Valdez; Jonathan M Chia; Thomas Coates; John C Wood
Journal:  Magn Reson Med       Date:  2017-06-22       Impact factor: 4.668

6.  Spectroscopy-based multi-parametric quantification in subjects with liver iron overload at 1.5T and 3T.

Authors:  Gregory Simchick; Ruiyang Zhao; Gavin Hamilton; Scott B Reeder; Diego Hernando
Journal:  Magn Reson Med       Date:  2021-09-23       Impact factor: 4.668

7.  Relaxivity-iron calibration in hepatic iron overload: Reproducibility and extension of a Monte Carlo model.

Authors:  Changqing Wang; Scott B Reeder; Diego Hernando
Journal:  NMR Biomed       Date:  2021-08-30       Impact factor: 4.044

8.  Does fat suppression via chemically selective saturation affect R2*-MRI for transfusional iron overload assessment? A clinical evaluation at 1.5T and 3T.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Xiao Bian; M Beth McCarville; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2015-08-26       Impact factor: 4.668

9.  Complex confounder-corrected R2* mapping for liver iron quantification with MRI.

Authors:  Diego Hernando; Rachel J Cook; Naila Qazi; Colin A Longhurst; Carol A Diamond; Scott B Reeder
Journal:  Eur Radiol       Date:  2020-08-12       Impact factor: 5.315

10.  Improving CPMG liver iron estimates with a T 1 -corrected proton density estimator.

Authors:  Eamon K Doyle; Samuel Thornton; Kristin A Toy; Andrew J Powell; John C Wood
Journal:  Magn Reson Med       Date:  2021-07-29       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.