Literature DB >> 18093781

Relaxation effects in the quantification of fat using gradient echo imaging.

Mark Bydder1, Takeshi Yokoo, Gavin Hamilton, Michael S Middleton, Alyssa D Chavez, Jeffrey B Schwimmer, Joel E Lavine, Claude B Sirlin.   

Abstract

Quantification of fat has been investigated using images acquired from multiple gradient echoes. The evolution of the signal with echo time and flip angle was measured in phantoms of known fat and water composition and in 21 research subjects with fatty liver. Data were compared to different models of the signal equation, in which each model makes different assumptions about the T1 and/or T2* relaxation effects. A range of T1, T2*, fat fraction and number of echoes was investigated to cover situations of relevance to clinical imaging. Results indicate that quantification is most accurate at low flip angles (to minimize T1 effects) with a small number of echoes (to minimize spectral broadening effects). At short echo times, the spectral broadening effects manifest as a short apparent T2 for the fat component.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18093781      PMCID: PMC2386876          DOI: 10.1016/j.mri.2007.08.012

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  16 in total

1.  Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia.

Authors:  Mark A Westwood; Lisa J Anderson; David N Firmin; Peter D Gatehouse; Christine H Lorenz; Beatrix Wonke; Dudley J Pennell
Journal:  J Magn Reson Imaging       Date:  2003-11       Impact factor: 4.813

2.  Multicoil Dixon chemical species separation with an iterative least-squares estimation method.

Authors:  Scott B Reeder; Zhifei Wen; Huanzhou Yu; Angel R Pineda; Garry E Gold; Michael Markl; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  Breath-hold water and fat imaging using a dual-echo two-point Dixon technique with an efficient and robust phase-correction algorithm.

Authors:  Jingfei Ma
Journal:  Magn Reson Med       Date:  2004-08       Impact factor: 4.668

4.  Cramér-Rao bounds for three-point decomposition of water and fat.

Authors:  Angel R Pineda; Scott B Reeder; Zhifei Wen; Norbert J Pelc
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

5.  In vivo quantitative characterization of trabecular bone by NMR interferometry and localized proton spectroscopy.

Authors:  J C Ford; F W Wehrli
Journal:  Magn Reson Med       Date:  1991-02       Impact factor: 4.668

6.  Multipoint Dixon technique for water and fat proton and susceptibility imaging.

Authors:  G H Glover
Journal:  J Magn Reson Imaging       Date:  1991 Sep-Oct       Impact factor: 4.813

7.  Accurate determination of spin-density and T1 in the presence of RF-field inhomogeneities and flip-angle miscalibration.

Authors:  R Venkatesan; W Lin; E M Haacke
Journal:  Magn Reson Med       Date:  1998-10       Impact factor: 4.668

8.  Improved method for accurate and efficient quantification of MRS data with use of prior knowledge

Authors: 
Journal:  J Magn Reson       Date:  1997-11       Impact factor: 2.229

9.  Introduction of fast MR imaging in the assessment of hepatic steatosis.

Authors:  M H Fishbein; K G Gardner; C J Potter; P Schmalbrock; M A Smith
Journal:  Magn Reson Imaging       Date:  1997       Impact factor: 2.546

10.  Simple proton spectroscopic imaging.

Authors:  W T Dixon
Journal:  Radiology       Date:  1984-10       Impact factor: 11.105

View more
  202 in total

1.  R*(2) mapping in the presence of macroscopic B₀ field variations.

Authors:  Diego Hernando; Karl K Vigen; Ann Shimakawa; Scott B Reeder
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

Review 2.  Magnetic resonance imaging quantification of liver iron.

Authors:  Claude B Sirlin; Scott B Reeder
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-08       Impact factor: 2.266

Review 3.  Quantitative Assessment of Liver Fat with Magnetic Resonance Imaging and Spectroscopy.

Authors:  Scott B Reeder; Irene Cruite; Gavin Hamilton; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2011-09-16       Impact factor: 4.813

Review 4.  Quantification of liver fat with magnetic resonance imaging.

Authors:  Scott B Reeder; Claude B Sirlin
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-08       Impact factor: 2.266

5.  In vivo characterization of the liver fat ¹H MR spectrum.

Authors:  Gavin Hamilton; Takeshi Yokoo; Mark Bydder; Irene Cruite; Michael E Schroeder; Claude B Sirlin; Michael S Middleton
Journal:  NMR Biomed       Date:  2010-12-12       Impact factor: 4.044

6.  Free-breathing liver fat and R 2 quantification using motion-corrected averaging based on a nonlocal means algorithm.

Authors:  Huiwen Luo; Ante Zhu; Curtis N Wiens; Jitka Starekova; Ann Shimakawa; Scott B Reeder; Kevin M Johnson; Diego Hernando
Journal:  Magn Reson Med       Date:  2020-08-01       Impact factor: 4.668

7.  Nonalcoholic fatty liver disease: MR imaging of liver proton density fat fraction to assess hepatic steatosis.

Authors:  An Tang; Justin Tan; Mark Sun; Gavin Hamilton; Mark Bydder; Tanya Wolfson; Anthony C Gamst; Michael Middleton; Elizabeth M Brunt; Rohit Loomba; Joel E Lavine; Jeffrey B Schwimmer; Claude B Sirlin
Journal:  Radiology       Date:  2013-02-04       Impact factor: 11.105

8.  Association between novel MRI-estimated pancreatic fat and liver histology-determined steatosis and fibrosis in non-alcoholic fatty liver disease.

Authors:  N S Patel; M R Peterson; D A Brenner; E Heba; C Sirlin; R Loomba
Journal:  Aliment Pharmacol Ther       Date:  2013-02-05       Impact factor: 8.171

9.  Automated unsupervised multi-parametric classification of adipose tissue depots in skeletal muscle.

Authors:  Alexander Valentinitsch; Dimitrios C Karampinos; Hamza Alizai; Karupppasamy Subburaj; Deepak Kumar; Thomas M Link; Sharmila Majumdar
Journal:  J Magn Reson Imaging       Date:  2012-10-23       Impact factor: 4.813

Review 10.  Measurement of liver fat fraction and iron with MRI and MR spectroscopy techniques.

Authors:  Puneet Sharma; Maria Altbach; Jean-Philippe Galons; Bobby Kalb; Diego R Martin
Journal:  Diagn Interv Radiol       Date:  2014 Jan-Feb       Impact factor: 2.630

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.