Literature DB >> 26305527

Corneal Deformation Response in Patients With Primary Open-Angle Glaucoma and in Healthy Subjects Analyzed by Corvis ST.

Wei Wang, Shaolin Du, Xiulan Zhang.   

Abstract

PURPOSE: To compare corneal deformation response between patients with primary open-angle glaucoma (POAG) and healthy subjects. A prevalent case-control study was conducted, followed by an integrated meta-analysis.
METHODS: Primary open-angle glaucoma was confirmed by presence of glaucomatous optic disc damage with corresponding visual field defect after excluding secondary causes. Age-matched controls were recruited. Corvis ST (CST) was used to measure 10 parameters of corneal deformation response and central corneal thickness (CCT). The association between parameters of deformation response and clinical factors was assessed by the linear regression analyses. Differences in deformation response between POAG and healthy subjects were compared after adjusting for other factors. Eligible studies were identified by a systematic search of the PubMed, ISI Web of Science, and Embase databases; Web sites of professional associations; and the Google Scholar engine.
RESULTS: This study included 37 patients with POAG and 36 healthy controls. Significant associations were found between IOP and the first applanation time (A1T), first applanation velocity (A1V), second applanation time (A2T), and second applanation velocity (A2V) in each group. The deformation amplitude (DA), A1V, and A2T were lower in the POAG group, whereas the A1T, A2V and peak distance (PD) were greater in the POAG group than in the healthy controls (all P < 0.05). Ten separate studies plus the present study, involving 691 patients with POAG and 740 controls, were ultimately meta-analyzed. The significant differences in the DA, A1T, and A2T were further confirmed, with pooled weighted mean difference (WMD) of 0.13 mm (95% CI 0.04-0.23; P = 0.008) for A1T, -0.13 mm (95% CI -0.21 to -0.05; P = 0.001) for DA, and -0.46 ms (95% CI -0.70 to -0.22; P < 0.001) for A2T.
CONCLUSIONS: The corneal response parameters provided by CST are informative for the assessment of corneal biomechanics. Patients with POAG showed significantly greater A1T and lower DA and A2T values than healthy controls, indicating a less deformable cornea in POAG patients.

Entities:  

Mesh:

Year:  2015        PMID: 26305527     DOI: 10.1167/iovs.15-16926

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  22 in total

1.  Deformable and conformal silk hydrogel inverse opal.

Authors:  Kyungtaek Min; Sookyoung Kim; Sunghwan Kim
Journal:  Proc Natl Acad Sci U S A       Date:  2017-05-30       Impact factor: 11.205

2.  Comparison of corneal biological parameters between transepithelial and epithelium-off corneal cross-linking in keratoconus.

Authors:  Bo-Wen Ouyang; Hui Ding; Han Wang; Zhen-Duo Yang; Tan Zhong; Hong-Ming Fan; Xing-Wu Zhong
Journal:  Int J Ophthalmol       Date:  2021-07-18       Impact factor: 1.779

Review 3.  [Dynamic Scheimpflug Analyzer (Corvis ST) for measurement of corneal biomechanical parameters : A praxis-related overview].

Authors:  R Herber; N Terai; K R Pillunat; F Raiskup; L E Pillunat; E Spörl
Journal:  Ophthalmologe       Date:  2018-08       Impact factor: 1.059

4.  Effect of topical prostaglandins on the biomechanics and shape of the cornea.

Authors:  Shiro Amano; Ryohei Nejima; Kenji Inoue; Kazunori Miyata
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-08-10       Impact factor: 3.117

5.  Comparison of corneal biomechanics in Sjögren's syndrome and non-Sjögren's syndrome dry eyes by Scheimpflug based device.

Authors:  Qin Long; Jing-Yi Wang; Dong Xu; Ying Li
Journal:  Int J Ophthalmol       Date:  2017-05-18       Impact factor: 1.779

6.  Evaluation of Corvis ST tonometer with the updated software in glaucoma practice.

Authors:  Ioannis Halkiadakis; Vasilios Tzimis; Alexandros Gryparis; Ioannis Markopoulos; Vasiliki Konstadinidou; Elias Zintzaras; Michalis Tzakos
Journal:  Int J Ophthalmol       Date:  2022-03-18       Impact factor: 1.779

7.  Measurement repeatability of the dynamic Scheimpflug analyzer.

Authors:  Atsuya Miki; Naoyuki Maeda; Tomoko Asai; Yasushi Ikuno; Kohji Nishida
Journal:  Jpn J Ophthalmol       Date:  2017-10-05       Impact factor: 2.447

8.  Association between optic nerve head morphology in open-angle glaucoma and corneal biomechanical parameters measured with Corvis ST.

Authors:  Shuichiro Aoki; Yoshiaki Kiuchi; Kana Tokumo; Yuri Fujino; Masato Matsuura; Hiroshi Murata; Shunsuke Nakakura; Ryo Asaoka
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-12-21       Impact factor: 3.117

9.  Changes in corneal biomechanics in patients with diabetes mellitus: a systematic review and meta-analysis.

Authors:  Xiaoyi Wang; Guihua Xu; Wei Wang; Juanjuan Wang; Lili Chen; Mingguang He; Zilin Chen
Journal:  Acta Diabetol       Date:  2020-03-22       Impact factor: 4.280

10.  Evaluation of rebound tonometer iCare IC200 as compared with IcarePRO and Goldmann applanation tonometer in patients with glaucoma.

Authors:  Shunsuke Nakakura; Ryo Asaoka; Etsuko Terao; Yuki Nagata; Yasuko Fukuma; Satomi Oogi; Miku Shiraishi; Yoshiaki Kiuchi
Journal:  Eye Vis (Lond)       Date:  2021-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.