Evaluation of Corvis ST tonometer with the updated software in glaucoma practice.

Ioannis Halkiadakis1, Vasilios Tzimis1, Alexandros Gryparis2, Ioannis Markopoulos1, Vasiliki Konstadinidou1, Elias Zintzaras3, Michalis Tzakos1.   

Abstract

AIM: To evaluate the agreement of biomechanically corrected intraocular pressure (b-IOP) and central corneal thickness (CCT) measurements obtained with the updated Corvis ST tonometer versus Goldmann applanation tonometry (GAT) and optical-based corneal pachymetry (OB-CCT) in controls, patients with ocular hypertension (OHT) and primary open angle glaucoma (POAG). Additionally, we examined the differences in corneal deformation parameters provided by the updated Corvis ST among the three groups.
METHODS: For each participant, GAT IOP, OB-CCT and measurements with a Corvis ST with updated software were obtained. Bland-Altman analysis was used to assess the agreement between the two measurement methods.
RESULTS: A consecutive series of 80 eyes from 80 participants (30 with POAG, 25 with OHT and 25 normal controls) were included in this prospective study. The mean GAT IOP of all eyes was 17.2±3.6 mm Hg, and the mean b-IOP was 15.9±3.7 mm Hg (Spearman's rho=0.767, P<0.001). The 95% limits of agreement (LoAs) ranged from -3.1 mm Hg to 5.5 mm Hg for GAT IOP and b-IOP. b-IOP was not correlated with OB-CCT (Spearman's rho=-0.13 P=0.917). Meanwhile there was a weak positive corelation between OB-CCT and GAT IOP-b-IOP difference (Spearman's rho=0.378, P=0.001). The mean OB-CCT was 549.5±36.4 µm, and the Corvis-CCT was 556.1±41.5 µm (Spearman's rho=0.900, P<0.001). No statistically significant difference in the new indices provided by the updated Corvis ST was detected among the three groups. Compared with control eyes, POAG eyes had a significantly reduced applanation time 2 after adjusting for OB-CCT and GAT IOP (P=0.048).
CONCLUSION: Corvis b-IOP and CCT correlate well with GAT IOP and OB-CCT. b-IOP is not affected by CCT, which might be an advantage, especially in thick or thin corneas. Corvis ST yields shorter applanation time 2 measurements in patients with POAG, which might reflect altered corneal viscoelasticity. International Journal of Ophthalmology Press.

Entities:  

Keywords:  corneal biomechanics; glaucoma; intraocular pressure; ocular hypertension; tonometry

Year:  2022        PMID: 35310063      PMCID: PMC8907045          DOI: 10.18240/ijo.2022.03.11

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  36 in total

1.  Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.

Authors:  Gabor Nemeth; Eszter Szalai; Ziad Hassan; Agnes Lipecz; Zsuzsa Flasko; Laszlo Modis
Journal:  Int J Ophthalmol       Date:  2017-02-18       Impact factor: 1.779

2.  Novel Parameter of Corneal Biomechanics That Differentiate Normals From Glaucoma.

Authors:  Rachel Lee; Robert T Chang; Ian Y H Wong; Jimmy S M Lai; Jacky W Y Lee; Kuldev Singh
Journal:  J Glaucoma       Date:  2016-06       Impact factor: 2.503

3.  Central corneal thickness measurements with different imaging devices and ultrasound pachymetry.

Authors:  Lai-Yong Tai; Keat-Ween Khaw; Choung-Min Ng; Visvaraja Subrayan
Journal:  Cornea       Date:  2013-06       Impact factor: 2.651

4.  Dynamic Scheimpflug Ocular Biomechanical Parameters in Healthy and Medically Controlled Glaucoma Eyes.

Authors:  Atsuya Miki; Yuichi Yasukura; Robert N Weinreb; Tomomi Yamada; Shizuka Koh; Tomoko Asai; Yasushi Ikuno; Naoyuki Maeda; Kohji Nishida
Journal:  J Glaucoma       Date:  2019-07       Impact factor: 2.503

5.  Latanoprost treatment differentially affects intraocular pressure readings obtained with three different tonometers.

Authors:  Cristina Sánchez-Barahona; Gema Bolívar; Andreas Katsanos; Miguel A Teus
Journal:  Acta Ophthalmol       Date:  2019-06-11       Impact factor: 3.761

6.  Evaluation of a novel Scheimpflug-based non-contact tonometer in healthy subjects and patients with ocular hypertension and glaucoma.

Authors:  Lukas Reznicek; Daniel Muth; Anselm Kampik; Aljoscha S Neubauer; Christoph Hirneiss
Journal:  Br J Ophthalmol       Date:  2013-08-22       Impact factor: 4.638

7.  Central corneal thickness and corneal hysteresis associated with glaucoma damage.

Authors:  Nathan G Congdon; Aimee T Broman; Karen Bandeen-Roche; Davinder Grover; Harry A Quigley
Journal:  Am J Ophthalmol       Date:  2006-03-09       Impact factor: 5.258

8.  Association between optic nerve head morphology in open-angle glaucoma and corneal biomechanical parameters measured with Corvis ST.

Authors:  Shuichiro Aoki; Yoshiaki Kiuchi; Kana Tokumo; Yuri Fujino; Masato Matsuura; Hiroshi Murata; Shunsuke Nakakura; Ryo Asaoka
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-12-21       Impact factor: 3.117

9.  Corneal biomechanics and biomechanically corrected intraocular pressure in primary open-angle glaucoma, ocular hypertension and controls.

Authors:  Riccardo Vinciguerra; Salwah Rehman; Neeru A Vallabh; Mark Batterbury; Gabriela Czanner; Anshoo Choudhary; Robert Cheeseman; Ahmed Elsheikh; Colin E Willoughby
Journal:  Br J Ophthalmol       Date:  2019-03-28       Impact factor: 4.638

10.  Changes in Corneal Biomechanical Properties after Long-Term Topical Prostaglandin Therapy.

Authors:  Na Wu; Yuhong Chen; Xiaobo Yu; Mengwei Li; Wen Wen; Xinghuai Sun
Journal:  PLoS One       Date:  2016-05-17       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.