Comparison of corneal biomechanics in Sjögren's syndrome and non-Sjögren's syndrome dry eyes by Scheimpflug based device.

Qin Long1, Jing-Yi Wang1, Dong Xu2, Ying Li1.   

Abstract

AIM: To compare the corneal biomechanics of Sjögren's syndrome (SS) and non-SS dry eyes with Corneal Visualization Scheimpflug Technology (CorVis ST).
METHODS: Corneal biomechanics and tear film parameters, namely the Schirmer I test value, tear film break-up time (TBUT) and corneal staining score (CSS) were detected in 34 eyes of 34 dry eye patients with SS (SSDE group) and 34 dry eye subjects without SS (NSSDE group) using CorVis ST. The differences of the above parameters between the two groups were examined, and the relationship between corneal biomechanics and tear film parameters were observed.
RESULTS: The differences in age, sex, intraocular pressure (IOP) and central corneal thickness (CCT) were not significant between the two groups (P>0.05). The tear film parameters had significant differences between the SSDE group and NSSDE group (all P<0.05). Patients in the SSDE group had significantly lower A1-time and HC-time, but higher DA (P=0.01, 0.02, and 0.02, respectively) compared with the NSSDE group. In the SSDE group, DA was negatively correlated with TBUT (rho=-0.38, P=0.03); HC-time was negatively correlated with CSS (rho=-0.43, P=0.02). In the NSSDE group, HC-time was again negatively correlated with CSS (rho=-0.39, P=0.02).
CONCLUSION: There are differences in corneal biomechanical properties between SSDE and NSSDE. The cornea of SSDE tends to show less "stiffness", as seen by a significantly shorter A1-time and HC-time, but larger DA, compared with the cornea of NSSDE. Biomechanical parameters can be influenced by different tear film parameters in both groups.

Entities:  

Keywords:  Sjögren's syndrome; corneal biomechanics; dry eye

Year:  2017        PMID: 28546925      PMCID: PMC5437456          DOI: 10.18240/ijo.2017.05.08

Source DB:  PubMed          Journal:  Int J Ophthalmol        ISSN: 2222-3959            Impact factor:   1.779


  40 in total

1.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

2.  Evaluation of patients with dry eye for presence of underlying Sjögren syndrome.

Authors:  Esen Karamursel Akpek; Alena Klimava; Jennifer E Thorne; Don Martin; Kaevalin Lekhanont; Ann Ostrovsky
Journal:  Cornea       Date:  2009-06       Impact factor: 2.651

3.  Repeatability of ocular biomechanical data measurements with a Scheimpflug-based noncontact device on normal corneas.

Authors:  Gabor Nemeth; Ziad Hassan; Adrienne Csutak; Eszter Szalai; Andras Berta; Laszlo Modis
Journal:  J Refract Surg       Date:  2013-08       Impact factor: 3.573

4.  Corneal biomechanical properties after LASIK, ReLEx flex, and ReLEx smile by Scheimpflug-based dynamic tonometry.

Authors:  Iben Bach Pedersen; Sashia Bak-Nielsen; Anders Højslet Vestergaard; Anders Ivarsen; Jesper Hjortdal
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-27       Impact factor: 3.117

5.  Evaluation of subjective assessments and objective diagnostic tests for diagnosing tear-film disorders known to cause ocular irritation.

Authors:  S C Pflugfelder; S C Tseng; O Sanabria; H Kell; C G Garcia; C Felix; W Feuer; B L Reis
Journal:  Cornea       Date:  1998-01       Impact factor: 2.651

6.  Tear evaporation rates in Sjögren syndrome and non-Sjögren dry eye patients.

Authors:  Eiki Goto; Yukihiro Matsumoto; Mizuka Kamoi; Koji Endo; Reiko Ishida; Murat Dogru; Minako Kaido; Takashi Kojima; Kazuo Tsubota
Journal:  Am J Ophthalmol       Date:  2007-05-23       Impact factor: 5.258

Review 7.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04

8.  Evaluation of corneal deformation analyzed with Scheimpflug based device in healthy eyes and diseased ones.

Authors:  Michele Lanza; Michela Cennamo; Stefania Iaccarino; Carlo Irregolare; Miguel Rechichi; Mario Bifani; Ugo Antonello Gironi Carnevale
Journal:  Biomed Res Int       Date:  2014-06-23       Impact factor: 3.411

9.  The histopathology of labial salivary glands in primary Sjögren's syndrome: focusing on follicular helper T cells in the inflammatory infiltrates.

Authors:  Krisztina Szabo; Gabor Papp; Balazs Dezso; Margit Zeher
Journal:  Mediators Inflamm       Date:  2014-08-07       Impact factor: 4.711

10.  Changes in Corneal Biomechanical Properties after Long-Term Topical Prostaglandin Therapy.

Authors:  Na Wu; Yuhong Chen; Xiaobo Yu; Mengwei Li; Wen Wen; Xinghuai Sun
Journal:  PLoS One       Date:  2016-05-17       Impact factor: 3.240

View more
  5 in total

Review 1.  [Dynamic Scheimpflug Analyzer (Corvis ST) for measurement of corneal biomechanical parameters : A praxis-related overview].

Authors:  R Herber; N Terai; K R Pillunat; F Raiskup; L E Pillunat; E Spörl
Journal:  Ophthalmologe       Date:  2018-08       Impact factor: 1.059

2.  Tear Osmolarity and Matrix Metallopeptidase-9 in Dry Eye Associated with Sjögren's Syndrome.

Authors:  Kyung Yun Kook; Rujun Jin; Lan Li; Hyeon Jeong Yoon; Kyung Chul Yoon
Journal:  Korean J Ophthalmol       Date:  2020-06

3.  Corneal biomechanical alterations in patients with chronic ocular Graft Versus-Host Disease.

Authors:  Giuseppe Giannaccare; Marco Pellegrini; Leonardo Taroni; Federico Bernabei; Carlotta Senni; Arianna Grendele; Vincenzo Scorcia; Emilio C Campos
Journal:  PLoS One       Date:  2019-04-25       Impact factor: 3.240

4.  Characteristics of dry eye in patients with pre-existing Sjögren's syndrome according to the revised 2016 ACR-EULAR classification criteria.

Authors:  Hyeon Jeong Yoon; Won Choi; Jee Myung Yang; Yong Sok Ji; Shin-Seok Lee; Kyung Chul Yoon
Journal:  Medicine (Baltimore)       Date:  2019-03       Impact factor: 1.889

Review 5.  Corneal Biomechanical Assessment with Ultra-High-Speed Scheimpflug Imaging During Non-Contact Tonometry: A Prospective Review.

Authors:  Pedro Manuel Baptista; Renato Ambrosio; Luis Oliveira; Pedro Meneres; Joao Melo Beirao
Journal:  Clin Ophthalmol       Date:  2021-04-06
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.