Anatomical-based partial volume correction for low-dose dedicated cardiac SPECT/CT.

Hui Liu1, Chung Chan, Yariv Grobshtein, Tianyu Ma, Yaqiang Liu, Shi Wang, Mitchel R Stacy, Albert J Sinusas, Chi Liu.   

Abstract

Due to the limited spatial resolution, partial volume effect has been a major degrading factor on quantitative accuracy in emission tomography systems. This study aims to investigate the performance of several anatomical-based partial volume correction (PVC) methods for a dedicated cardiac SPECT/CT system (GE Discovery NM/CT 570c) with focused field-of-view over a clinically relevant range of high and low count levels for two different radiotracer distributions. These PVC methods include perturbation geometry transfer matrix (pGTM), pGTM followed by multi-target correction (MTC), pGTM with known concentration in blood pool, the former followed by MTC and our newly proposed methods, which perform the MTC method iteratively, where the mean values in all regions are estimated and updated by the MTC-corrected images each time in the iterative process. The NCAT phantom was simulated for cardiovascular imaging with (99m)Tc-tetrofosmin, a myocardial perfusion agent, and (99m)Tc-red blood cell (RBC), a pure intravascular imaging agent. Images were acquired at six different count levels to investigate the performance of PVC methods in both high and low count levels for low-dose applications. We performed two large animal in vivo cardiac imaging experiments following injection of (99m)Tc-RBC for evaluation of intramyocardial blood volume (IMBV). The simulation results showed our proposed iterative methods provide superior performance than other existing PVC methods in terms of image quality, quantitative accuracy, and reproducibility (standard deviation), particularly for low-count data. The iterative approaches are robust for both (99m)Tc-tetrofosmin perfusion imaging and (99m)Tc-RBC imaging of IMBV and blood pool activity even at low count levels. The animal study results indicated the effectiveness of PVC to correct the overestimation of IMBV due to blood pool contamination. In conclusion, the iterative PVC methods can achieve more accurate quantification, particularly for low count cardiac SPECT studies, typically obtained from low-dose protocols, gated studies, and dynamic applications.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26296043      PMCID: PMC4747118          DOI: 10.1088/0031-9155/60/17/6751

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  Correction of partial-volume effect for PET striatal imaging: fast implementation and study of robustness.

Authors:  Vincent Frouin; Claude Comtat; Anthonin Reilhac; Marie-Claude Grégoire
Journal:  J Nucl Med       Date:  2002-12       Impact factor: 10.057

2.  Relationship between arterial diameter and perfused tissue volume in myocardial microcirculation: a micro-CT-based analysis.

Authors:  Nasser M Malyar; Mario Gössl; Patricia E Beighley; Erik L Ritman
Journal:  Am J Physiol Heart Circ Physiol       Date:  2003-12-11       Impact factor: 4.733

3.  Quantitative accuracy of dopaminergic neurotransmission imaging with (123)I SPECT.

Authors:  Marine Soret; Pierre Malick Koulibaly; Jacques Darcourt; Sébastien Hapdey; Irène Buvat
Journal:  J Nucl Med       Date:  2003-07       Impact factor: 10.057

4.  Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects.

Authors:  H W Müller-Gärtner; J M Links; J L Prince; R N Bryan; E McVeigh; J P Leal; C Davatzikos; J J Frost
Journal:  J Cereb Blood Flow Metab       Date:  1992-07       Impact factor: 6.200

5.  Diminishing the impact of the partial volume effect in cardiac SPECT perfusion imaging.

Authors:  P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

6.  Correction for partial volume effects in PET: principle and validation.

Authors:  O G Rousset; Y Ma; A C Evans
Journal:  J Nucl Med       Date:  1998-05       Impact factor: 10.057

7.  A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential.

Authors:  Moshe Bocher; Ira M Blevis; Leonid Tsukerman; Yigal Shrem; Gil Kovalski; Lana Volokh
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06-29       Impact factor: 9.236

8.  The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation.

Authors:  Rolf Vogel; Andreas Indermühle; Jessica Reinhardt; Pascal Meier; Patrick T Siegrist; Mehdi Namdar; Philipp A Kaufmann; Christian Seiler
Journal:  J Am Coll Cardiol       Date:  2005-03-01       Impact factor: 24.094

9.  Partial volume correction strategies for quantitative FDG PET in oncology.

Authors:  Nikie J Hoetjes; Floris H P van Velden; Otto S Hoekstra; Corneline J Hoekstra; Nanda C Krak; Adriaan A Lammertsma; Ronald Boellaard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-04-27       Impact factor: 9.236

10.  3D iteratively reconstructed spatial resolution map and sensitivity characterization of a dedicated cardiac SPECT camera.

Authors:  John A Kennedy; Ora Israel; Alex Frenkel
Journal:  J Nucl Cardiol       Date:  2014-01-16       Impact factor: 5.952

View more
  5 in total

1.  Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT.

Authors:  Qingyi Liu; Hassan Mohy-Ud-Din; Nabil E Boutagy; Mingyan Jiang; Silin Ren; John C Stendahl; Albert J Sinusas; Chi Liu
Journal:  Phys Med Biol       Date:  2017-03-07       Impact factor: 3.609

2.  Noise suppressed partial volume correction for cardiac SPECT/CT.

Authors:  Chung Chan; Hui Liu; Yariv Grobshtein; Mitchel R Stacy; Albert J Sinusas; Chi Liu
Journal:  Med Phys       Date:  2016-09       Impact factor: 4.071

Review 3.  Nuclear Cardiac Imaging in the Interventional Suite.

Authors:  Zachary Pickell; Albert J Sinusas
Journal:  Curr Cardiol Rep       Date:  2022-01-13       Impact factor: 2.931

4.  Non-invasive measures of coronary microcirculation: Taking the long road to the clinic.

Authors:  Kieran S Chung; Patricia K Nguyen
Journal:  J Nucl Cardiol       Date:  2017-07-18       Impact factor: 5.952

5.  The impact of system matrix dimension on small FOV SPECT reconstruction with truncated projections.

Authors:  Chung Chan; Joyoni Dey; Yariv Grobshtein; Jing Wu; Yi-Hwa Liu; Rachel Lampert; Albert J Sinusas; Chi Liu
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.