Noise suppressed partial volume correction for cardiac SPECT/CT.

Chung Chan1, Hui Liu2, Yariv Grobshtein3, Mitchel R Stacy4, Albert J Sinusas5, Chi Liu1.   

Abstract

PURPOSE: Partial volume correction (PVC) methods typically improve quantification at the expense of increased image noise and reduced reproducibility. In this study, the authors developed a novel voxel-based PVC method that incorporates anatomical knowledge to improve quantification while suppressing noise for cardiac SPECT/CT imaging.
METHODS: In the proposed method, the SPECT images were first reconstructed using anatomical-based maximum a posteriori (AMAP) with Bowsher's prior to penalize noise while preserving boundaries. A sequential voxel-by-voxel PVC approach (Yang's method) was then applied on the AMAP reconstruction using a template response. This template response was obtained by forward projecting a template derived from a contrast-enhanced CT image, and then reconstructed using AMAP to model the partial volume effects (PVEs) introduced by both the system resolution and the smoothing applied during reconstruction. To evaluate the proposed noise suppressed PVC (NS-PVC), the authors first simulated two types of cardiac SPECT studies: a (99m)Tc-tetrofosmin myocardial perfusion scan and a (99m)Tc-labeled red blood cell (RBC) scan on a dedicated cardiac multiple pinhole SPECT/CT at both high and low count levels. The authors then applied the proposed method on a canine equilibrium blood pool study following injection with (99m)Tc-RBCs at different count levels by rebinning the list-mode data into shorter acquisitions. The proposed method was compared to MLEM reconstruction without PVC, two conventional PVC methods, including Yang's method and multitarget correction (MTC) applied on the MLEM reconstruction, and AMAP reconstruction without PVC.
RESULTS: The results showed that the Yang's method improved quantification, however, yielded increased noise and reduced reproducibility in the regions with higher activity. MTC corrected for PVE on high count data with amplified noise, although yielded the worst performance among all the methods tested on low-count data. AMAP effectively suppressed noise and reduced the spill-in effect in the low activity regions. However it was unable to reduce the spill-out effect in high activity regions. NS-PVC yielded superior performance in terms of both quantitative assessment and visual image quality while improving reproducibility.
CONCLUSIONS: The results suggest that NS-PVC may be a promising PVC algorithm for application in low-dose protocols, and in gated and dynamic cardiac studies with low counts.

Entities:  

Mesh:

Year:  2016        PMID: 27587054      PMCID: PMC5001975          DOI: 10.1118/1.4961391

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  42 in total

1.  Evaluation of three MRI-based anatomical priors for quantitative PET brain imaging.

Authors:  Kathleen Vunckx; Ameya Atre; Kristof Baete; Anthonin Reilhac; Christophe M Deroose; Koen Van Laere; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2011-10-27       Impact factor: 10.048

2.  Partial volume effect compensation for quantitative brain SPECT imaging.

Authors:  Yong Du; Benjamin M W Tsui; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2005-08       Impact factor: 10.048

3.  Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET.

Authors:  Sangtae Ahn; Steven G Ross; Evren Asma; Jun Miao; Xiao Jin; Lishui Cheng; Scott D Wollenweber; Ravindra M Manjeshwar
Journal:  Phys Med Biol       Date:  2015-07-09       Impact factor: 3.609

4.  End-expiration respiratory gating for a high-resolution stationary cardiac SPECT system.

Authors:  Chung Chan; Mark Harris; Max Le; James Biondi; Yariv Grobshtein; Yi-Hwa Liu; Albert J Sinusas; Chi Liu
Journal:  Phys Med Biol       Date:  2014-09-26       Impact factor: 3.609

5.  The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation.

Authors:  Rolf Vogel; Andreas Indermühle; Jessica Reinhardt; Pascal Meier; Patrick T Siegrist; Mehdi Namdar; Philipp A Kaufmann; Christian Seiler
Journal:  J Am Coll Cardiol       Date:  2005-03-01       Impact factor: 24.094

6.  Targeted imaging of the spatial and temporal variation of matrix metalloproteinase activity in a porcine model of postinfarct remodeling: relationship to myocardial dysfunction.

Authors:  Zakir H Sahul; Rupak Mukherjee; James Song; Jarod McAteer; Robert E Stroud; Donald P Dione; Lawrence Staib; Xenophon Papademetris; Lawrence W Dobrucki; James S Duncan; Francis G Spinale; Albert J Sinusas
Journal:  Circ Cardiovasc Imaging       Date:  2011-04-19       Impact factor: 7.792

7.  Partial-volume correction in PET: validation of an iterative postreconstruction method with phantom and patient data.

Authors:  Boon-Keng Teo; Youngho Seo; Stephen L Bacharach; Jorge A Carrasquillo; Steven K Libutti; Himanshu Shukla; Bruce H Hasegawa; Randall A Hawkins; Benjamin L Franc
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

Review 8.  Clinical myocardial perfusion PET/CT.

Authors:  Marcelo F Di Carli; Sharmila Dorbala; Jolene Meserve; Georges El Fakhri; Arkadiusz Sitek; Stephen C Moore
Journal:  J Nucl Med       Date:  2007-05       Impact factor: 10.057

9.  3D iteratively reconstructed spatial resolution map and sensitivity characterization of a dedicated cardiac SPECT camera.

Authors:  John A Kennedy; Ora Israel; Alex Frenkel
Journal:  J Nucl Cardiol       Date:  2014-01-16       Impact factor: 5.952

Review 10.  Diagnosing coronary artery disease with hybrid PET/CT: it takes two to tango.

Authors:  Ibrahim Danad; Pieter G Raijmakers; Paul Knaapen
Journal:  J Nucl Cardiol       Date:  2013-10       Impact factor: 5.952

View more
  3 in total

1.  Fully automatic multi-atlas segmentation of CTA for partial volume correction in cardiac SPECT/CT.

Authors:  Qingyi Liu; Hassan Mohy-Ud-Din; Nabil E Boutagy; Mingyan Jiang; Silin Ren; John C Stendahl; Albert J Sinusas; Chi Liu
Journal:  Phys Med Biol       Date:  2017-03-07       Impact factor: 3.609

Review 2.  Nuclear Cardiac Imaging in the Interventional Suite.

Authors:  Zachary Pickell; Albert J Sinusas
Journal:  Curr Cardiol Rep       Date:  2022-01-13       Impact factor: 2.931

3.  Non-invasive measures of coronary microcirculation: Taking the long road to the clinic.

Authors:  Kieran S Chung; Patricia K Nguyen
Journal:  J Nucl Cardiol       Date:  2017-07-18       Impact factor: 5.952

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.