Literature DB >> 19697090

The John Charnley Award: Metal-on-metal hip resurfacing versus large-diameter head metal-on-metal total hip arthroplasty: a randomized clinical trial.

Donald S Garbuz1, Michael Tanzer, Nelson V Greidanus, Bassam A Masri, Clive P Duncan.   

Abstract

UNLABELLED: Resurfacing arthroplasty has become an attractive option for young patients who want to maintain a high activity level. One recent study reported modestly increased activity levels for patients with resurfacing compared to standard total hip arthroplasty (THA). We conducted a prospective randomized clinical trial to compare clinical outcomes of resurfacing versus large-head metal-on-metal total hip arthroplasty. We randomized 107 patients deemed eligible for resurfacing arthroplasty to have either resurfacing or standard THA. Patients were assessed for quality-of-life outcomes using the PAT-5D index, WOMAC, SF-36, and UCLA activity score. The minimum followup was 0.8 years (mean, 1.1 years; range, 0.8-2.2 years). Of the 73 patients followed at least one year, both groups reported improvement in quality of life on all outcome measures. There was no difference in quality of life between the two arms in the study. Serum levels of cobalt and chromium were measured in a subset of 30 patients. In both groups cobalt and chromium was elevated compared to baseline. Patients receiving a large-head metal-on-metal total hip had elevated ion levels compared to the resurfacing arm of the study. At 1 year, the median serum cobalt increased 46-fold from baseline in patients in the large-head total hip group, while the median serum chromium increased 10-fold. At 1 year, serum cobalt was 10-fold higher and serum chromium 2.6-fold higher than in the resurfacing arm. Due to these excessively high metal ion levels, the authors recommend against further use of this particular large-head total hip arthroplasty. LEVEL OF EVIDENCE: Level I, randomized clinical trial. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19697090      PMCID: PMC2806981          DOI: 10.1007/s11999-009-1029-x

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  Metallosis due to impingement between the socket and the femoral neck in a metal-on-metal bearing total hip prosthesis. A case report.

Authors:  H Iida; E Kaneda; H Takada; K Uchida; K Kawanabe; T Nakamura
Journal:  J Bone Joint Surg Am       Date:  1999-03       Impact factor: 5.284

2.  Serum cobalt levels after metal-on-metal total hip arthroplasty.

Authors:  Wolfram Brodner; Peter Bitzan; Vanee Meisinger; Alexandra Kaider; Florian Gottsauner-Wolf; Rainer Kotz
Journal:  J Bone Joint Surg Am       Date:  2003-11       Impact factor: 5.284

3.  Removal of acetabular bone in resurfacing arthroplasty of the hip: a comparison with hybrid total hip arthroplasty.

Authors:  J M Loughead; I Starks; D Chesney; J N S Matthews; A W McCaskie; J P Holland
Journal:  J Bone Joint Surg Br       Date:  2006-01

4.  The results of primary Birmingham hip resurfacings at a mean of five years. An independent prospective review of the first 230 hips.

Authors:  C B Hing; D L Back; M Bailey; D A Young; R E Dalziel; A J Shimmin
Journal:  J Bone Joint Surg Br       Date:  2007-11

5.  Assessing activity in joint replacement patients.

Authors:  C A Zahiri; T P Schmalzried; E S Szuszczewicz; H C Amstutz
Journal:  J Arthroplasty       Date:  1998-12       Impact factor: 4.757

6.  Pseudotumours associated with metal-on-metal hip resurfacings.

Authors:  H Pandit; S Glyn-Jones; P McLardy-Smith; R Gundle; D Whitwell; C L M Gibbons; S Ostlere; N Athanasou; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2008-07

Review 7.  Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.

Authors:  P-A Vendittoli; S Mottard; A G Roy; C Dupont; M Lavigne
Journal:  J Bone Joint Surg Br       Date:  2007-04

8.  Metal-on-metal hybrid surface arthroplasty: two to six-year follow-up study.

Authors:  Harlan C Amstutz; Paul E Beaulé; Frederick J Dorey; Michel J Le Duff; Pat A Campbell; Thomas A Gruen
Journal:  J Bone Joint Surg Am       Date:  2004-01       Impact factor: 5.284

9.  A double-blind study of 250 cases comparing cemented with cementless total hip arthroplasty. Cost-effectiveness and its impact on health-related quality of life.

Authors:  C H Rorabeck; R B Bourne; A Laupacis; D Feeny; C Wong; P Tugwell; K Leslie; R Bullas
Journal:  Clin Orthop Relat Res       Date:  1994-01       Impact factor: 4.176

10.  A prospective randomized clinical trial comparing metal-on-metal total hip arthroplasty and metal-on-metal total hip resurfacing in patients less than 65 years old.

Authors:  P-A Vendittoli; M Lavigne; A-G Roy; D Lusignan
Journal:  Hip Int       Date:  2006       Impact factor: 1.756

View more
  92 in total

1.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  CORR Insights ®: High prevalence of adverse reactions to metal debris in small-headed ASR™ hips.

Authors:  William Macaulay
Journal:  Clin Orthop Relat Res       Date:  2013-06-21       Impact factor: 4.176

Review 3.  Surgical management of hip osteoarthritis.

Authors:  Rajiv Gandhi; Anthony V Perruccio; Nizar N Mahomed
Journal:  CMAJ       Date:  2013-10-21       Impact factor: 8.262

4.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

5.  Subcapital correction osteotomy for malunited slipped capital femoral epiphysis.

Authors:  Lucas A Anderson; Jeremy M Gililland; Christoper E Pelt; Christopher L Peters
Journal:  J Pediatr Orthop       Date:  2013-06       Impact factor: 2.324

6.  Metal-on-metal hip prostheses: correlation between debris in the synovial fluid and levels of cobalt and chromium ions in the bloodstream.

Authors:  Dalila De Pasquale; Susanna Stea; Stefano Squarzoni; Barbara Bordini; Marilina Amabile; Simona Catalani; Pietro Apostoli; Aldo Toni
Journal:  Int Orthop       Date:  2014-03       Impact factor: 3.075

7.  Surface replacement of the hip can result in decreased acetabular bone stock.

Authors:  Michael Tanzer; Dylan Tanzer; Karen Smith
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 8.  [Evidence-based update in hip arthroplasty].

Authors:  H Gollwitzer; L Gerdesmeyer; R Gradinger; R von Eisenhart-Rothe
Journal:  Orthopade       Date:  2011-06       Impact factor: 1.087

9.  The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty.

Authors:  Sulaiman A Almousa; Nelson V Greidanus; Bassam A Masri; Clive P Duncan; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

10.  What Is the Natural History of Asymptomatic Pseudotumors in Metal-on-metal THAs at Mid-term Followup?

Authors:  Sujith Konan; Clive P Duncan; Bassam S Masri; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2017-02       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.