Literature DB >> 26631286

Gender Differences in Wear Rates for 28- vs 32-mm Ceramic Femoral Heads on Modern Highly Cross-linked Polyethylene at Midterm Follow-Up in Young Patients Undergoing Total Hip Arthroplasty.

Jeffrey B Stambough1, Gail Pashos1, Ningying Wu2, Jacob A Haynes1, John M Martell3, John C Clohisy1.   

Abstract

BACKGROUND: We report on the midterm linear and volumetric wear of highly cross-linked polyethylene (HXLPE) and survivorship of 2 prospective young total hip arthroplasty (THA) cohorts that differed by the size of ceramic femoral head used: 28 vs 32 mm.
METHODS: We prospectively analyzed 220 consecutive primary THAs in patients aged ≤50 years who received a cementless THA with a ceramic femoral head on HXLPE liner (C-HXLPE). There were 101 patients (46%) with 28-mm heads and 119 patients (54%) who received 32-mm heads at a mean follow-up of 5.5 years (range, 60-109 months). Wear was calculated using Martell Software.
RESULTS: The 28-mm C-HXLPE cohort demonstrated average linear and volumetric wear of 0.020 mm/y (standard deviation [SD], 0.074; 95% CI, 0.003-0.037) and 18.775 mm(3)/y (SD, 21.743; 95% CI, 13.773-23.778) compared with 0.032 mm/y (SD, 0.087; 95% CI, 0.013-0.050]) and 29.847 mm(3)/y (SD, 35.441; 95% CI, 22.294-37.401) in the 32-mm C-HXLPE group. Subgroup analysis by gender and head size discovered significantly greater wear in females with 32-mm heads compared with 28-mm heads in both linear (0.01, 95% CI = -0.014 to 0.033 vs 0.048, 95% CI = 0.022-0.074 mm/y, P = .004) and volumetric wear (14.11, 95% CI = 8.957-19.271] vs 29.71, 95% CI = 17.584-41.840] mm(3)/y, P = .009). We found a 96% (95% CI = 92.30%-97.94%]) survivorship by Kaplan-Meier analysis at minimum 5 years with no failures because of osteolysis.
CONCLUSIONS: Ceramic on HXLPE demonstrates extremely low wear properties in young patients at midterm follow-up. We identified a gender-dependent difference in wear based on head size, with 32-mm heads being associated with increased wear in females.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Martell method; gender differences; highly cross-linked polyethylene; total hip arthroplasty outcomes; wear

Mesh:

Substances:

Year:  2015        PMID: 26631286      PMCID: PMC5374861          DOI: 10.1016/j.arth.2015.10.024

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  41 in total

1.  Minimum 5-year wear analysis of first-generation highly cross-linked polyethylene in patients 65 years and younger.

Authors:  Amar S Ranawat; Panagiotis Tsailis; Morteza Meftah; Trevor W Koob; Jose A Rodriguez; Chitranjan S Ranawat
Journal:  J Arthroplasty       Date:  2011-12-15       Impact factor: 4.757

2.  A prospective randomised controlled trial comparing three alternative bearing surfaces in primary total hip replacement.

Authors:  V S Nikolaou; M R Edwards; E Bogoch; E H Schemitsch; J P Waddell
Journal:  J Bone Joint Surg Br       Date:  2012-04

3.  A double-blind, prospective, randomized controlled trial comparing highly cross-linked and conventional polyethylene in primary total hip arthroplasty.

Authors:  George T Calvert; Peter A Devane; Jan Fielden; Kathryn Adams; J Geoffrey Horne
Journal:  J Arthroplasty       Date:  2008-06-10       Impact factor: 4.757

4.  Comparison of the responsiveness of the Harris Hip Score with generic measures for hip function in osteoarthritis of the hip.

Authors:  H L Hoeksma; C H M Van Den Ende; H K Ronday; A Heering; F C Breedveld
Journal:  Ann Rheum Dis       Date:  2003-10       Impact factor: 19.103

5.  Determination of polyethylene wear in total hip replacements with use of digital radiographs.

Authors:  J M Martell; S Berdia
Journal:  J Bone Joint Surg Am       Date:  1997-11       Impact factor: 5.284

6.  Impact of the economic downturn on total joint replacement demand in the United States: updated projections to 2021.

Authors:  Steven M Kurtz; Kevin L Ong; Edmund Lau; Kevin J Bozic
Journal:  J Bone Joint Surg Am       Date:  2014-04-16       Impact factor: 5.284

7.  Stress fracture in military recruits: gender differences in muscle and bone susceptibility factors.

Authors:  T J Beck; C B Ruff; R A Shaffer; K Betsinger; D W Trone; S K Brodine
Journal:  Bone       Date:  2000-09       Impact factor: 4.398

8.  THA with highly cross-linked polyethylene in patients 50 years or younger.

Authors:  Derek S Shia; John C Clohisy; Mark F Schinsky; John M Martell; William J Maloney
Journal:  Clin Orthop Relat Res       Date:  2009-01-14       Impact factor: 4.176

9.  Intermediate results of simultaneous alumina-on-alumina bearing and alumina-on-highly cross-linked polyethylene bearing total hip arthroplasties.

Authors:  Young-Hoo Kim; Jun-Shik Kim; Yoo-Wang Choi; Oh-Ryong Kwon
Journal:  J Arthroplasty       Date:  2008-07-09       Impact factor: 4.757

10.  Wear rate of highly cross-linked polyethylene in total hip arthroplasty. A randomized controlled trial.

Authors:  Richard W McCalden; Steven J MacDonald; Cecil H Rorabeck; Robert B Bourne; David G Chess; Kory D Charron
Journal:  J Bone Joint Surg Am       Date:  2009-04       Impact factor: 5.284

View more
  2 in total

1.  Polyethylene and highly cross-linked polyethylene for cemented total hip arthroplasty: A comparison of over ten-year clinical and radiographic results.

Authors:  Tomotoshi Kawata; Koji Goto; Kazutaka So; Yutaka Kuroda; Shuichi Matsuda
Journal:  J Orthop       Date:  2017-08-10

2.  Failure to Meet Same-Day Discharge is Not a Predictor of Adverse Outcomes.

Authors:  Vivek Singh; Afamefuna M Nduaguba; William Macaulay; Ran Schwarzkopf; Roy I Davidovitch
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-01       Impact factor: 3.067

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.