| Literature DB >> 26207142 |
Simon J Otter1, Brunilda Agalliu1, Nicola Baer1, Georgie Hales1, Katrina Harvey1, Keeley James1, Richard Keating1, Warren McConnell1, Rachel Nelson1, Saddaf Qureshi1, Steven Ryan1, Abigail St John1, Heather Waddington1, Katie Warren1, Duane Wong1.
Abstract
BACKGROUND: Adequate sagittal plane motion of the first metatarsalphalangeal joint (1st MTPJ) is important during normal gait and goniometric measurement is commonly used as a diagnostic and outcome assessment tool. We aimed to determine the intra and inter-rater reliability together with the concurrent validity of a universal plastic goniometer (UG) and a smartphone applicationlication (Dr G) for the measurement of dorsiflexion at the 1st MTPJ.Entities:
Keywords: Biomechanics Cell phone; First metatarsophalangeal joint; Reproducibility of results
Year: 2015 PMID: 26207142 PMCID: PMC4512018 DOI: 10.1186/s13047-015-0088-3
Source DB: PubMed Journal: J Foot Ankle Res ISSN: 1757-1146 Impact factor: 2.303
Fig. 1Location of skin markers
Fig. 2Screenshot of smartphone app
Intra and inter-rater reliability for measuring joint position
| Universal goniometer | Smartphone app | |
|---|---|---|
| 1st MTPJ dorsiflexion Mean (SD) | Mean 32° (SD 8.37) | Mean 27.8° (SD 11.7) |
| Rater 1 Intra-rater reliability | ICC 0.861 (95 % CI 0.702 to 0.937) SEM 2 | ICC 0.807 (95 % CI 0.603 to 0.912) SEM 1.5 |
| Rater 2 Intra-rater reliability | ICC 0.709 (95 % CI 0.448 to 0.860) SEM 1.8 | ICC 0.853 (95 % CI 0.689 to 0.934) SEM 1.5 |
| Rater 3 Intra-rater reliability | ICC 0.829 (95 % CI 0.652 to 0.921) SEM 1.5 | ICC 0.768 (95 % CI 0.537 to 0.893) SEM 2.0 |
| Rater 4 Intra-rater reliability | ICC 0.857 (95 % CI 0.697 to 0.935) SEM 1.6 | ICC 0.929 (95 % CI 0.836 to 0.969) SEM 1.6 |
| Rater 5 Intra-rater reliability | ICC 0.861 (95 % CI 0.707 to 0.937) SEM 1.4 | ICC 0.907 (95 % CI 0.796 to 0.959) SEM 1.3 |
| Average inter-rater reliability | ICC 0.823 (95 % CI 0.642 to 0.918 | ICC 0.853 (95 % CI 0.692 to 0.933) |
| Inter-rater reliability | ICC 0.785 (95 % CI 0.675 to 0.882) | ICC 0.832 (95 % CI 0.737 to 0.911) |
SEM standard error of mean
IC inter class correlation coefficient
CI confidence intervals
Intra and inter-rater reliability for measuring passive joint motion
| 1st MTPJ ROM | Universal Goniometer | Smartphone app |
|---|---|---|
| Mean (SD) | 82.8° (12.2) | 82.9° (11.3) |
| Rater 1 Intra-rater reliability | ICC 0.869 (95 % CI 0.793 to 0.918) SEM 1.6 | ICC 0.869 (95 % CI 0.794 to 0.918) SEM 1.7 |
| Rater 2 Intra-rater reliability | ICC 0.771 (95 % CI 0.650 to 0.854) SEM 1.6 | ICC 0.886 (95 % CI 0.819 to 0.929) SEM 1.4 |
| Rater 3 Intra-rater reliability | ICC 0.809 (95 % CI 0.672 to 0.864) SEM 1.4 | ICC 0.870 (95 % CI 0.795 to 0.919) SEM 1.4 |
| Average intra rater reliability | ICC 0.809 (95 % CI 0.705 to 0.879) | ICC 0.875 (95 % CI 0.803 to 0.922) |
| Inter-rater reliability | ICC 0.693 (95 % CI 0.580 to 0.788) | ICC 0.708 (95 % CI 0.597 to 0.799) |
ROM, range of motion
SEM, standard error of mean
ICC, inter class correlation coefficient
CI, confidence intervals