Literature DB >> 22421186

Within-day reliability of shoulder range of motion measurement with a smartphone.

Seung Han Shin1, Du Hyun Ro, O-Sung Lee, Joo Han Oh, Sae Hoon Kim.   

Abstract

Measuring range of motion (ROM) is the first step of a physical examination and functional evaluation of the shoulder joint. Digital inclinometers are available on the market; however, they are expensive, and hence will not come into wide use. In this study, we present a new method for the shoulder ROM measurement using the inclinometer application on a smartphone. We hypothesized that the method would demonstrate acceptable reliability and reproducibility. Three observers performed goniometric and smartphone inclinometric measurements of various shoulder movements, including both active and passive ROM for forward flexion, abduction, external rotation while the arms are at the sides, external rotation at 90° abduction, and internal rotation at 90° abduction. Measurements were performed in the affected shoulders of 41 patients. All measurements were taken twice to assess the intra-observer reliability. Inter- and intra-observer reliabilities were evaluated using the intraclass correlation coefficient (ICC). Reliability between two measurements was also assessed in terms of the ICC. Both the goniometric and inclinometric measurements showed satisfactory inter-observer reliability except for internal rotation at 90° abduction for which the ICC value was <0.7 (range, 0.63-0.68). Intra-observer reliability was excellent with an ICC value>0.9, except for some movements. Within-day inclinometric measurements with a smartphone showed acceptable reliability compared to the classical goniometric measurements of movements and the correlation between the two measurements was fairly high. Considering convenience and cost-effectiveness, this new method could be widely used for measuring the shoulder ROM, although the between-day reliability needs to be established first.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22421186     DOI: 10.1016/j.math.2012.02.010

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  26 in total

1.  Getting smarter with patient positioning.

Authors:  L R Kidd; T Deen
Journal:  J Robot Surg       Date:  2015-03-26

2.  The Unsupported Upper Limb Exercise Test in People Without Disabilities: Assessing the Within-Day Test-Retest Reliability and the Effects of Age and Gender.

Authors:  Ana Oliveira; Joana Cruz; Cristina Jácome; Alda Marques
Journal:  Physiother Can       Date:  2018       Impact factor: 1.037

3.  REACTIVE NEUROMUSCULAR TRAINING RESULTS IN IMMEDIATE AND LONG TERM IMPROVEMENTS IN MEASURES OF HAMSTRING FLEXIBILITY: A CASE REPORT.

Authors:  Rick A Loutsch; Russell T Baker; James M May; Alan M Nasypany
Journal:  Int J Sports Phys Ther       Date:  2015-06

4.  Biopsychosocial Influences on Shoulder Pain: Analyzing the Temporal Ordering of Postoperative Recovery.

Authors:  Corey B Simon; Carolina Valencia; Rogelio A Coronado; Samuel S Wu; Zhigang Li; Yunfeng Dai; Kevin W Farmer; Michael M Moser; Thomas W Wright; Roger B Fillingim; Steven Z George
Journal:  J Pain       Date:  2019-12-28       Impact factor: 5.820

Review 5.  Smart Technology and Orthopaedic Surgery: Current Concepts Regarding the Impact of Smartphones and Wearable Technology on Our Patients and Practice.

Authors:  Neil V Shah; Richard Gold; Qurratul-Ain Dar; Bassel G Diebo; Carl B Paulino; Qais Naziri
Journal:  Curr Rev Musculoskelet Med       Date:  2021-11-03

6.  The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion.

Authors:  Simon J Otter; Brunilda Agalliu; Nicola Baer; Georgie Hales; Katrina Harvey; Keeley James; Richard Keating; Warren McConnell; Rachel Nelson; Saddaf Qureshi; Steven Ryan; Abigail St John; Heather Waddington; Katie Warren; Duane Wong
Journal:  J Foot Ankle Res       Date:  2015-07-23       Impact factor: 2.303

7.  Reliability and criterion validity of two applications of the iPhone™ to measure cervical range of motion in healthy participants.

Authors:  Yannick Tousignant-Laflamme; Nicolas Boutin; Alexandre M Dion; Carol-Anne Vallée
Journal:  J Neuroeng Rehabil       Date:  2013-07-05       Impact factor: 4.262

8.  Validity and reliability of arm abduction angle measured on smartphone: a cross-sectional study.

Authors:  Antonio I Cuesta-Vargas; Cristina Roldán-Jiménez
Journal:  BMC Musculoskelet Disord       Date:  2016-02-20       Impact factor: 2.362

9.  Reliability of measuring the passive range of shoulder horizontal adduction using a smartphone in the supine versus the side-lying position.

Authors:  Jin-Yong Lim; Tae-Ho Kim; Jung-Seok Lee
Journal:  J Phys Ther Sci       Date:  2015-10-30

Review 10.  Mobile Phone-Based Joint Angle Measurement for Functional Assessment and Rehabilitation of Proprioception.

Authors:  Quentin Mourcou; Anthony Fleury; Bruno Diot; Céline Franco; Nicolas Vuillerme
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.