Literature DB >> 15940597

Radiographic investigation of angular and linear measurements including first metatarsophalangeal joint dorsiflexion and rearfoot to forefoot axis angle.

Michael J Taranto1, Julie Taranto, Alan Bryant, Kevin P Singer.   

Abstract

This study investigated intra- and inter-rater reliability of several radiographic angular and linear parameters using 6 subjects. Using standard weight-bearing radiographs, the following measurements were performed: first metatarsal protrusion distance, hallux abductus, first intermetatarsal, calcaneal inclination and lateral intermetatarsal angles. Measurement of lateral stressed dorsiflexion of the first metatarsophalangeal joint and the rearfoot-to-forefoot-axis angle taken using a composite view were also obtained. All parameters were measured independently by 2 raters, and measurements were repeated on 3 separate occasions at weekly intervals. Intrarater reliability of radiographic measurements ranged between R = 0.65-1.00 for lateral stressed dorsiflexion, and between R = 0.91 and 0.99 for the rearfoot to forefoot axis angle. Inter-rater reliability of radiographic measurements ranged from R = 0.82-0.99. Specifically, lateral stressed dorsiflexion showed R = 0.87 with a mean difference of -1.47 (confidence interval [CI]: -3.42, 0.47), indicating no significant difference ( t = 1.54, P = 0.13). The rearfoot-to-forefoot-axis angle showed R = 0.92 with a mean difference of -0.15 (CI: -1.05, 0.74), indicating no significant difference ( t = 0.35, P = 0.73). The 7 angular and linear measurements chosen demonstrated high inter- and intrarater reliability. These results indicate that weight-bearing radiographic first metatarsophalangeal joint dorsiflexion using the lateral stressed dorsiflexion view, and measurement of the rearfoot-to-forefoot-axis angle using a composite view could be measured reliably within and between raters.

Entities:  

Mesh:

Year:  2005        PMID: 15940597     DOI: 10.1053/j.jfas.2005.02.011

Source DB:  PubMed          Journal:  J Foot Ankle Surg        ISSN: 1067-2516            Impact factor:   1.286


  2 in total

1.  The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion.

Authors:  Simon J Otter; Brunilda Agalliu; Nicola Baer; Georgie Hales; Katrina Harvey; Keeley James; Richard Keating; Warren McConnell; Rachel Nelson; Saddaf Qureshi; Steven Ryan; Abigail St John; Heather Waddington; Katie Warren; Duane Wong
Journal:  J Foot Ankle Res       Date:  2015-07-23       Impact factor: 2.303

2.  Relationship between patient-reported outcome measures (PROM) and three measures of foot-ankle alignment in patients with metatarsal head pain: a cross-sectional study.

Authors:  Manuel González-Sánchez; Esther Velasco-Ramos; Maria Ruiz Muñoz; Antonio I Cuesta-Vargas
Journal:  J Foot Ankle Res       Date:  2016-12-16       Impact factor: 2.303

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.