Literature DB >> 20621547

Reliability of a new hand-held dynamometer in measuring shoulder range of motion and strength.

Angela Cadogan1, Mark Laslett, Wayne Hing, Peter McNair, Maynard Williams.   

Abstract

Acceptable reliability is a prerequisite for inclusion of physical examination tests in clinical examinations of the painful shoulder. The aim of this study was to establish the intraexaminer and interexaminer reliability of measures of shoulder range of motion (ROM) and muscle force using a new hand-held dynamometer with the ability to standardize overpressure force during passive ROM tests. Forty consecutive subjects with shoulder pain were recruited, and tests were performed by two physiotherapists. Tests included active ROM elevation, passive ROM glenohumeral abduction and external rotation and resisted abduction and external rotation. All tests demonstrated high levels of intraexaminer reliability (ICC 0.85-0.99; LOA 6-24° and 1.1-7.0 kg). Highest levels of interexaminer reliability reliability were observed for measures of active ROM flexion (ICC 0.88-0.95; LOA 14-22°). Passive ROM tests demonstrated 'moderate - substantial' interexaminer reliability (ICC 0.45-0.62; LOA 25-34°). The ICCs for resisted tests ranged from 0.68 to 0.84, and LOA ranged from 3.2 to 8.5 kg. Active ROM flexion demonstrated high levels of both intra- and interexaminer reliability. Measures of passive ROM and peak isometric force demonstrated acceptable levels of intraexaminer reliability.
Copyright © 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 20621547     DOI: 10.1016/j.math.2010.05.005

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  23 in total

1.  Eccentric and isometric shoulder rotator cuff strength testing using a hand-held dynamometer: reference values for overhead athletes.

Authors:  Ann M J Cools; Fran Vanderstukken; Frédéric Vereecken; Mattias Duprez; Karel Heyman; Nick Goethals; Fredrik Johansson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-08-21       Impact factor: 4.342

Review 2.  The Digital Neurologic Examination.

Authors:  Adam B Cohen; Brain V Nahed
Journal:  Digit Biomark       Date:  2021-04-26

3.  The Takei Handheld Dynamometer: An Effective Clinical Outcome Measure Tool for Hand and Wrist Function in Boxing.

Authors:  Ian Gatt; Sophie Smith-Moore; Charlie Steggles; Mike Loosemore
Journal:  Hand (N Y)       Date:  2017-05-10

4.  Measuring Eccentric Strength of the Shoulder External Rotators Using a Handheld Dynamometer: Reliability and Validity.

Authors:  Fredrik R Johansson; Eva Skillgate; Mattis L Lapauw; Dorien Clijmans; Valentijn P Deneulin; Tanneke Palmans; Human Kinetic Engineer; Ann M Cools
Journal:  J Athl Train       Date:  2015-05-14       Impact factor: 2.860

5.  Elastic Resistance Effectiveness on Increasing Strength of Shoulders and Hips.

Authors:  Kelsey J Picha; Muataz R Almaddah; Jordan Barker; Tavis Ciochetty; W Scott Black; Tim L Uhl
Journal:  J Strength Cond Res       Date:  2019-04       Impact factor: 3.775

6.  Diagnostic accuracy of clinical examination features for identifying large rotator cuff tears in primary health care.

Authors:  Angela Cadogan; Peter McNair; Mark Laslett; Wayne Hing; Stephen Taylor
Journal:  J Man Manip Ther       Date:  2013-08

7.  The relationship between physical impairments, quality of life and disability of the neck and upper limb in patients following neck dissection.

Authors:  Elise M Gane; Steven M McPhail; Anna L Hatton; Benedict J Panizza; Shaun P O'Leary
Journal:  J Cancer Surviv       Date:  2018-05-16       Impact factor: 4.442

8.  Reliability of new software in measuring cervical multifidus diameters and shoulder muscle strength in a synchronized way; an ultrasonographic study.

Authors:  Leila Rahnama; Asghar Rezasoltani; Minoo Khalkhali-Zavieh; Behnam Rahnama; Farhang Noori-Kochi
Journal:  Braz J Phys Ther       Date:  2015-09-01       Impact factor: 3.377

9.  Prevention of shoulder injuries in overhead athletes: a science-based approach.

Authors:  Ann M Cools; Fredrik R Johansson; Dorien Borms; Annelies Maenhout
Journal:  Braz J Phys Ther       Date:  2015-09-01       Impact factor: 3.377

10.  Reliability and group differences in quantitative cervicothoracic measures among individuals with and without chronic neck pain.

Authors:  Bahar Shahidi; Cynthia L Johnson; Douglas Curran-Everett; Katrina S Maluf
Journal:  BMC Musculoskelet Disord       Date:  2012-10-31       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.