Literature DB >> 12079902

How reliably do rheumatologists measure shoulder movement?

J L Hoving1, R Buchbinder, S Green, A Forbes, N Bellamy, C Brand, R Buchanan, S Hall, M Patrick, P Ryan, A Stockman.   

Abstract

OBJECTIVE: To assess the intrarater and interrater reliability among rheumatologists of a standardised protocol for measurement of shoulder movements using a gravity inclinometer.
METHODS: After instruction, six rheumatologists independently assessed eight movements of the shoulder, including total and glenohumeral flexion, total and glenohumeral abduction, external rotation in neutral and in abduction, internal rotation in abduction and hand behind back, in random order in six patients with shoulder pain and stiffness according to a 6x6 Latin square design using a standardised protocol. These assessments were then repeated. Analysis of variance was used to partition total variability into components of variance in order to calculate intraclass correlation coefficients (ICCs).
RESULTS: The intrarater and interrater reliability of different shoulder movements varied widely. The movement of hand behind back and total shoulder flexion yielded the highest ICC scores for both intrarater reliability (0.91 and 0.83, respectively) and interrater reliability (0.80 and 0.72, respectively). Low ICC scores were found for the movements of glenohumeral abduction, external rotation in abduction, and internal rotation in abduction (intrarater ICCs 0.35, 0.43, and 0.32, respectively), and external rotation in neutral, external rotation in abduction, and internal rotation in abduction (interrater ICCs 0.29, 0.11, and 0.06, respectively).
CONCLUSIONS: The measurement of shoulder movements using a standardised protocol by rheumatologists produced variable intrarater and interrater reliability. Reasonable reliability was obtained only for the movement of hand behind back and total shoulder flexion.

Entities:  

Mesh:

Year:  2002        PMID: 12079902      PMCID: PMC1754152          DOI: 10.1136/ard.61.7.612

Source DB:  PubMed          Journal:  Ann Rheum Dis        ISSN: 0003-4967            Impact factor:   19.103


  15 in total

1.  The reproducibility of measurement of shoulder movement.

Authors:  P D Triffitt; C Wildin; D Hajioff
Journal:  Acta Orthop Scand       Date:  1999-08

2.  The reliability of the three-dimensional FASTRAK measurement system in measuring cervical spine and shoulder range of motion in healthy subjects.

Authors:  K Jordan; K Dziedzic; P W Jones; B N Ong; P T Dawes
Journal:  Rheumatology (Oxford)       Date:  2000-04       Impact factor: 7.580

3.  Variability and reliability of joint measurements.

Authors:  A M Bovens; M A van Baak; J G Vrencken; J A Wijnen; F T Verstappen
Journal:  Am J Sports Med       Date:  1990 Jan-Feb       Impact factor: 6.202

4.  Intratester and intertester reliability of goniometric measurement of passive lateral shoulder rotation.

Authors:  J C MacDermid; B M Chesworth; S Patterson; J H Roth
Journal:  J Hand Ther       Date:  1999 Jul-Sep       Impact factor: 1.950

5.  Decreased shoulder range of motion on paretic side after stroke.

Authors:  A W Andrews; R W Bohannon
Journal:  Phys Ther       Date:  1989-09

6.  Shoulder joint movement and its relationship to disability in the elderly.

Authors:  K Chakravarty; M Webley
Journal:  J Rheumatol       Date:  1993-08       Impact factor: 4.666

7.  Observer variability in measuring elevation and external rotation of the shoulder. Primary Care Rheumatology Society Shoulder Study Group.

Authors:  P Croft; D Pope; R Boswell; A Rigby; A Silman
Journal:  Br J Rheumatol       Date:  1994-10

8.  Flexibility of the shoulder joint measured as range of abduction in a large representative sample of men and women over 65 years of age.

Authors:  E J Bassey; K Morgan; H M Dallosso; S B Ebrahim
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1989

9.  Reliability of goniometric measurements in patients with Duchenne muscular dystrophy.

Authors:  S Pandya; J M Florence; W M King; J D Robison; M Oxman; M A Province
Journal:  Phys Ther       Date:  1985-09

10.  Goniometric reliability in a clinical setting. Shoulder measurements.

Authors:  D L Riddle; J M Rothstein; R L Lamb
Journal:  Phys Ther       Date:  1987-05
View more
  18 in total

1.  Does a positive neer impingement sign reflect rotator cuff contact with the acromion?

Authors:  Xiaofeng Jia; Jong Hun Ji; Vinodhkumar Pannirselvam; Steve A Petersen; Edward G McFarland
Journal:  Clin Orthop Relat Res       Date:  2010-09-28       Impact factor: 4.176

2.  Effectiveness of manual physical therapy for painful shoulder conditions: a systematic review.

Authors:  James Camarinos; Lee Marinko
Journal:  J Man Manip Ther       Date:  2009

3.  Evaluating change in clinical status: reliability and measures of agreement for the assessment of glenohumeral range of motion.

Authors:  Susan W Muir; Charlene Luciak Corea; Lauren Beaupre
Journal:  N Am J Sports Phys Ther       Date:  2010-09

4.  Upper limb joint position sense during shoulder flexion in healthy individuals: a pilot study to develop a new assessment method.

Authors:  Kerry Glendon; Victoria Hood
Journal:  Shoulder Elbow       Date:  2015-09-03

5.  Is soft tissue massage an effective treatment for mechanical shoulder pain? A study protocol.

Authors:  Paul van den Dolder; Paulo Ferreira; Kathryn Refshauge
Journal:  J Man Manip Ther       Date:  2010-03

6.  The relationship between physical impairments, quality of life and disability of the neck and upper limb in patients following neck dissection.

Authors:  Elise M Gane; Steven M McPhail; Anna L Hatton; Benedict J Panizza; Shaun P O'Leary
Journal:  J Cancer Surviv       Date:  2018-05-16       Impact factor: 4.442

7.  Interrater reproducibility of clinical tests for rotator cuff lesions.

Authors:  A J K Ostor; C A Richards; A T Prevost; B L Hazleman; C A Speed
Journal:  Ann Rheum Dis       Date:  2004-10       Impact factor: 19.103

8.  Diagnosing soft tissue rheumatic disorders of the upper limb in epidemiological studies of vibration-exposed populations.

Authors:  Keith T Palmer
Journal:  Int Arch Occup Environ Health       Date:  2007-10-02       Impact factor: 3.015

9.  Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer.

Authors:  Andrea F de Winter; Monique A M B Heemskerk; Caroline B Terwee; Marielle P Jans; Walter Devillé; Dirk-Jan van Schaardenburg; Rob J P M Scholten; Lex M Bouter
Journal:  BMC Musculoskelet Disord       Date:  2004-06-14       Impact factor: 2.362

10.  Range of shoulder motion in patients with adhesive capsulitis; intra-tester reproducibility is acceptable for group comparisons.

Authors:  Einar Kristian Tveitå; Ole Marius Ekeberg; Niels Gunnar Juel; Erik Bautz-Holter
Journal:  BMC Musculoskelet Disord       Date:  2008-04-12       Impact factor: 2.362

View more