Literature DB >> 26183425

Partial fourier and parallel MR image reconstruction with integrated gradient nonlinearity correction.

Shengzhen Tao1,2, Joshua D Trzasko1, Yunhong Shu1, Paul T Weavers1, John Huston1, Erin M Gray1, Matt A Bernstein1.   

Abstract

PURPOSE: To describe how integrated gradient nonlinearity (GNL) correction can be used within noniterative partial Fourier (homodyne) and parallel (SENSE and GRAPPA) MR image reconstruction strategies, and demonstrate that performing GNL correction during, rather than after, these routines mitigates the image blurring and resolution loss caused by postreconstruction image domain based GNL correction.
METHODS: Starting from partial Fourier and parallel magnetic resonance imaging signal models that explicitly account for GNL, noniterative image reconstruction strategies for each accelerated acquisition technique are derived under the same core mathematical assumptions as their standard counterparts. A series of phantom and in vivo experiments on retrospectively undersampled data were performed to investigate the spatial resolution benefit of integrated GNL correction over conventional postreconstruction correction.
RESULTS: Phantom and in vivo results demonstrate that the integrated GNL correction reduces the image blurring introduced by the conventional GNL correction, while still correcting GNL-induced coarse-scale geometrical distortion. Images generated from undersampled data using the proposed integrated GNL strategies offer superior depiction of fine image detail, for example, phantom resolution inserts and anatomical tissue boundaries.
CONCLUSION: Noniterative partial Fourier and parallel imaging reconstruction methods with integrated GNL correction reduce the resolution loss that occurs during conventional postreconstruction GNL correction while preserving the computational efficiency of standard reconstruction techniques. Magn Reson Med 75:2534-2544, 2016.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  GRAPPA; SENSE; gradient nonlinearity; homodyne; nonuniform fast Fourier transform; parallel imaging; partial Fourier

Mesh:

Year:  2015        PMID: 26183425      PMCID: PMC4716004          DOI: 10.1002/mrm.25842

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  18 in total

1.  Modular gradient coil: A new concept in high-performance whole-body gradient coil design.

Authors:  P R Harvey; E Katznelson
Journal:  Magn Reson Med       Date:  1999-09       Impact factor: 4.668

2.  Interpolation revisited.

Authors:  P Thévenaz; T Blu; M Unser
Journal:  IEEE Trans Med Imaging       Date:  2000-07       Impact factor: 10.048

3.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

4.  Reliability in multi-site structural MRI studies: effects of gradient non-linearity correction on phantom and human data.

Authors:  Jorge Jovicich; Silvester Czanner; Douglas Greve; Elizabeth Haley; Andre van der Kouwe; Randy Gollub; David Kennedy; Franz Schmitt; Gregory Brown; James Macfall; Bruce Fischl; Anders Dale
Journal:  Neuroimage       Date:  2005-11-21       Impact factor: 6.556

5.  A complete distortion correction for MR images: I. Gradient warp correction.

Authors:  Simon J Doran; Liz Charles-Edwards; Stefan A Reinsberg; Martin O Leach
Journal:  Phys Med Biol       Date:  2005-03-16       Impact factor: 3.609

6.  Characterization, prediction, and correction of geometric distortion in 3 T MR images.

Authors:  Lesley N Baldwin; Keith Wachowicz; Steven D Thomas; Ryan Rivest; B Gino Fallone
Journal:  Med Phys       Date:  2007-02       Impact factor: 4.071

7.  Integrated image reconstruction and gradient nonlinearity correction.

Authors:  Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; John Huston; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2014-10-08       Impact factor: 4.668

8.  Peripheral vasculature: high-temporal- and high-spatial-resolution three-dimensional contrast-enhanced MR angiography.

Authors:  Clifton R Haider; James F Glockner; Anthony W Stanson; Stephen J Riederer
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

9.  Investigation of MR image distortion for radiotherapy treatment planning of prostate cancer.

Authors:  Z Chen; C-M Ma; K Paskalev; J Li; J Yang; T Richardson; L Palacio; X Xu; L Chen
Journal:  Phys Med Biol       Date:  2006-02-21       Impact factor: 3.609

10.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

View more
  6 in total

1.  Partial fourier shells trajectory for non-cartesian MRI.

Authors:  Shengzhen Tao; Yunhong Shu; Joshua D Trzasko; John Huston; Matt A Bernstein
Journal:  Phys Med Biol       Date:  2019-02-06       Impact factor: 3.609

2.  Magnetization-prepared shells trajectory with automated gradient waveform design.

Authors:  Yunhong Shu; Shengzhen Tao; Joshua D Trzasko; John Huston; Paul T Weavers; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2017-08-21       Impact factor: 4.668

3.  Image-based gradient non-linearity characterization to determine higher-order spherical harmonic coefficients for improved spatial position accuracy in magnetic resonance imaging.

Authors:  Paul T Weavers; Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; Erik J Tryggestad; Jeffrey L Gunter; Kiaran P McGee; Daniel V Litwiller; Ken-Pin Hwang; Matt A Bernstein
Journal:  Magn Reson Imaging       Date:  2016-12-27       Impact factor: 2.546

4.  Gradient nonlinearity calibration and correction for a compact, asymmetric magnetic resonance imaging gradient system.

Authors:  S Tao; J D Trzasko; J L Gunter; P T Weavers; Y Shu; J Huston; S K Lee; E T Tan; M A Bernstein
Journal:  Phys Med Biol       Date:  2016-12-29       Impact factor: 3.609

5.  The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems.

Authors:  Shengzhen Tao; Paul T Weavers; Joshua D Trzasko; John Huston; Yunhong Shu; Erin M Gray; Thomas K F Foo; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2017-06-22       Impact factor: 4.668

6.  Optimization of MRI Gradient Coils With Explicit Peripheral Nerve Stimulation Constraints.

Authors:  Mathias Davids; Bastien Guerin; Valerie Klein; Lawrence L Wald
Journal:  IEEE Trans Med Imaging       Date:  2020-12-29       Impact factor: 10.048

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.