Literature DB >> 26158072

Evaluation of penalty design in penalized maximum-likelihood image reconstruction for lesion detection.

Li Yang1, Andrea Ferrero1, Rosalie J Hagge2, Ramsey D Badawi3, Jinyi Qi1.   

Abstract

Detecting cancerous lesions is a major clinical application in emission tomography. Previously, we developed a method to design a shift-variant quadratic penalty function in penalized maximum-likelihood (PML) image reconstruction to improve the lesion detectability. We used a multiview channelized Hotelling observer (mvCHO) to assess the lesion detectability in three-dimensional images and validated the penalty design using computer simulations. In this study, we evaluate the benefit of the proposed penalty function for lesion detection using real patient data and artificial lesions. A high-count real patient dataset with no identifiable tumor inside the field of view is used as the background data. A Na-22 point source is scanned in air at variable locations and the point source data are superimposed onto the patient data as artificial lesions after being attenuated by the patient body. Independent Poisson noise is introduced to the high-count sinograms to generate 200 pairs of lesion-present and lesion-absent datasets, each mimicking a 5-min scan. Lesion detectability is assessed using a mvCHO and a human observer two-alternative forced choice (2AFC) experiment. The results show improvements in lesion detection by the proposed method compared with the conventional first-order quadratic penalty function and a total variation (TV) edge-preserving penalty function.

Entities:  

Keywords:  PET; lesion detection; multiview channelized Hotelling observer; penalized maximum-likelihood reconstruction

Year:  2014        PMID: 26158072      PMCID: PMC4286231          DOI: 10.1117/1.JMI.1.3.035501

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  22 in total

1.  A theoretical study of the contrast recovery and variance of MAP reconstructions from PET data.

Authors:  J Qi; R M Leahy
Journal:  IEEE Trans Med Imaging       Date:  1999-04       Impact factor: 10.048

2.  Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems.

Authors:  J Webster Stayman; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2004-03       Impact factor: 10.048

3.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

4.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images.

Authors:  E U Mumcuoglu; R Leahy; S R Cherry; Z Zhou
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

5.  Regularization design in penalized maximum-likelihood image reconstruction for lesion detection in 3D PET.

Authors:  Li Yang; Jian Zhou; Andrea Ferrero; Ramsey D Badawi; Jinyi Qi
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

6.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

7.  Results of a clinical receiver operating characteristic study comparing filtered backprojection and maximum likelihood estimator images in FDG PET studies.

Authors:  J Llacer; E Veklerov; L R Baxter; S T Grafton; L K Griffeth; R A Hawkins; C K Hoh; J C Mazziotta; E J Hoffman; C E Metz
Journal:  J Nucl Med       Date:  1993-07       Impact factor: 10.057

8.  Comparison of receiver operating characteristic and forced choice observer performance measurement methods.

Authors:  A E Burgess
Journal:  Med Phys       Date:  1995-05       Impact factor: 4.071

9.  Quadratic regularization design for 2-D CT.

Authors:  Hugo R Shi; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2008-10-31       Impact factor: 10.048

10.  Comparison of Lesion Detection and Quantification in MAP Reconstruction with Gaussian and Non-Gaussian Priors.

Authors:  Jinyi Qi
Journal:  Int J Biomed Imaging       Date:  2006-06-29
View more
  3 in total

1.  Robust regression-based estimation of isocenter offset with subpixel precision in tomographic image reconstruction.

Authors:  Xuelin Cui; Lamine Mili; Ibrahim Bechwati; Shouhua Luo
Journal:  J Med Imaging (Bellingham)       Date:  2019-11-15

2.  Theoretical Analysis of Penalized Maximum-Likelihood Patlak Parametric Image Reconstruction in Dynamic PET for Lesion Detection.

Authors:  Li Yang; Guobao Wang; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2015-11-23       Impact factor: 10.048

3.  An improved patch-based regularization method for PET image reconstruction.

Authors:  Juan Gao; Qiegen Liu; Chao Zhou; Weiguang Zhang; Qian Wan; Chenxi Hu; Zheng Gu; Dong Liang; Xin Liu; Yongfeng Yang; Hairong Zheng; Zhanli Hu; Na Zhang
Journal:  Quant Imaging Med Surg       Date:  2021-02
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.