Comparison of receiver operating characteristic and forced choice observer performance measurement methods.

A E Burgess1.   

Abstract

The receiver operating characteristic (ROC) method has been successfully used in medical imaging for 20 years. It has been so successful that many people think of it as an end in itself rather than just one of several ways to assess human observer performance of image based decision tasks. Studies of human and ideal observer decision performance are designed to estimate a measure of observer performance (e.g., efficiency, d' or da). The experimenter would like to obtain accurate and precise estimates using a relatively small number of images or decision trials because of a variety of constraints. One purpose of this paper is to introduce medical physicists to another effective psychophysical measurement technique, the forced choice method. The second purpose is to present a comparison of the forced choice and ROC methods, with particular attention to sampling statistics considerations. In brief, the rating scale ROC method is preferable when the limiting constraint is the number of images and at the same time it is not feasible to use the forced choice with more than four alternatives. The forced choice method can be superior for experiments using synthetic images, under some conditions.

Entities:  

Mesh:

Year:  1995        PMID: 7643805     DOI: 10.1118/1.597576

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  25 in total

1.  Observer signal-to-noise ratios for the ML-EM algorithm.

Authors:  Craig K Abbey; Harrison H Barrett; Donald W Wilson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  1996-01-01

2.  Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction.

Authors:  Brendan L Eck; Rachid Fahmi; Kevin M Brown; Stanislav Zabic; Nilgoun Raihani; Jun Miao; David L Wilson
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

3.  A search model and figure of merit for observer data acquired according to the free-response paradigm.

Authors:  D P Chakraborty
Journal:  Phys Med Biol       Date:  2006-07-06       Impact factor: 3.609

4.  A psychophysical test of the visual pathway of children with autism.

Authors:  Francisco J Sanchez-Marin; Jose A Padilla-Medina
Journal:  J Autism Dev Disord       Date:  2007-12-05

5.  Detection of simulated microcalcifications in a phantom with digital mammography: effect of pixel size.

Authors:  Sankararaman Suryanarayanan; Andrew Karellas; Srinivasan Vedantham; Ioannis Sechopoulos; Carl J D'Orsi
Journal:  Radiology       Date:  2007-05-23       Impact factor: 11.105

6.  Visibility of microcalcification in cone beam breast CT: effects of X-ray tube voltage and radiation dose.

Authors:  Chao-Jen Lai; Chris C Shaw; Lingyun Chen; Mustafa C Altunbas; Xinming Liu; Tao Han; Tianpeng Wang; Wei T Yang; Gary J Whitman; Shu-Ju Tu
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

7.  Observer efficiency in discrimination tasks simulating malignant and benign breast lesions imaged with ultrasound.

Authors:  Craig K Abbey; Roger J Zemp; Jie Liu; Karen K Lindfors; Michael F Insana
Journal:  IEEE Trans Med Imaging       Date:  2006-02       Impact factor: 10.048

8.  Validation of CT dose-reduction simulation.

Authors:  Parinaz Massoumzadeh; Steven Don; Charles F Hildebolt; Kyongtae T Bae; Bruce R Whiting
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

9.  Quantitative image quality evaluation of MR images using perceptual difference models.

Authors:  Jun Miao; Donglai Huo; David L Wilson
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

10.  An alternate method for using a visual discrimination model (VDM) to optimize soft-copy display image quality.

Authors:  Dev P Chakraborty
Journal:  J Soc Inf Disp       Date:  2006-10       Impact factor: 2.140

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.