Results of a clinical receiver operating characteristic study comparing filtered backprojection and maximum likelihood estimator images in FDG PET studies.

J Llacer1, E Veklerov, L R Baxter, S T Grafton, L K Griffeth, R A Hawkins, C K Hoh, J C Mazziotta, E J Hoffman, C E Metz.   

Abstract

The results of a receiver operator characteristic (ROC) study comparing maximum likelihood estimator (MLE) reconstructions of human FDG PET brain scan data to filtered backprojection reconstructions of the same data are reported. The purpose of the study was to determine whether MLE reconstructions would result in higher detectability of small focal lesions introduced artificially into otherwise normal scan data. One physician assisted in defining the location and intensity of the lesions and five physicians read the final images. Data from 90 datasets were used for the study. Of those, 42 were left in their original "normal" condition and 48 were modified by added lesions. All datasets were reconstructed by the two methods and submitted to the five physicians for evaluation. The results show an increase in the area under the ROC curve from approximately 0.65 for filtered backprojection to approximately 0.71 for the maximum likelihood reconstructions for four of the five observers with good statistical significance.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 8315502

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

1.  Evaluation of penalty design in penalized maximum-likelihood image reconstruction for lesion detection.

Authors:  Li Yang; Andrea Ferrero; Rosalie J Hagge; Ramsey D Badawi; Jinyi Qi
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-08

2.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

3.  Image reconstruction for PET/CT scanners: past achievements and future challenges.

Authors:  Shan Tong; Adam M Alessio; Paul E Kinahan
Journal:  Imaging Med       Date:  2010-10-01

Review 4.  Quantitative statistical methods for image quality assessment.

Authors:  Joyita Dutta; Sangtae Ahn; Quanzheng Li
Journal:  Theranostics       Date:  2013-10-04       Impact factor: 11.556

5.  Patient specific quality assurance for the delivery of intensity modulated radiotherapy.

Authors:  Nzhde Agazaryan; Timothy D Solberg; John J DeMarco
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.