Literature DB >> 26158045

Energy weighting improves dose efficiency in clinical practice: implementation on a spectral photon-counting mammography system.

Johan Berglund1, Henrik Johansson1, Mats Lundqvist1, Björn Cederström1, Erik Fredenberg1.   

Abstract

In x-ray imaging, contrast information content varies with photon energy. It is, therefore, possible to improve image quality by weighting photons according to energy. We have implemented and evaluated so-called energy weighting on a commercially available spectral photon-counting mammography system. The technique was evaluated using computer simulations, phantom experiments, and analysis of screening mammograms. The CNR benefit of energy weighting for a number of relevant target-background combinations measured by the three methods fell in the range of 2.2 to 5.2% when using optimal weight factors. This translates to a potential dose reduction at constant CNR in the range of 4.5 to 11%. We expect the choice of weight factor in practical implementations to be straightforward because (1) the CNR improvement was not very sensitive to weight, (2) the optimal weight was similar for all investigated target-background combinations, (3) aluminum/PMMA phantoms were found to represent clinically relevant tasks well, and (4) the optimal weight could be calculated directly from pixel values in phantom images. Reasonable agreement was found between the simulations and phantom measurements. Manual measurements on microcalcifications and automatic image analysis confirmed that the CNR improvement was detectable in energy-weighted screening mammograms.

Entities:  

Keywords:  contrast-to-noise ratio; digital mammography; dose efficiency; energy weighting; photon counting; spectral x-ray imaging

Year:  2014        PMID: 26158045      PMCID: PMC4478791          DOI: 10.1117/1.JMI.1.3.031003

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  19 in total

1.  Estimation of the noisy component of anatomical backgrounds.

Authors:  F O Bochud; J F Valley; F R Verdun; C Hessler; P Schnyder
Journal:  Med Phys       Date:  1999-07       Impact factor: 4.071

2.  Detective quantum efficiency dependence on x-ray energy weighting in mammography.

Authors:  R N Cahn; B Cederström; M Danielsson; A Hall; M Lundqvist; D Nygren
Journal:  Med Phys       Date:  1999-12       Impact factor: 4.071

3.  Quantification of breast density with spectral mammography based on a scanned multi-slit photon-counting detector: a feasibility study.

Authors:  Huanjun Ding; Sabee Molloi
Journal:  Phys Med Biol       Date:  2012-07-06       Impact factor: 3.609

4.  Scatter rejection in multislit digital mammography.

Authors:  Magnus Aslund; Björn Cederström; Mats Lundqvist; Mats Danielsson
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

5.  Single-shot dual-energy subtraction mammography with electronic spectrum splitting: feasibility.

Authors:  Hans Bornefalk; John M Lewin; Mats Danielsson; Mats Lundqvist
Journal:  Eur J Radiol       Date:  2006-10-16       Impact factor: 3.528

6.  Measurement of breast-tissue x-ray attenuation by spectral mammography: first results on cyst fluid.

Authors:  Erik Fredenberg; David R Dance; Paula Willsher; Elin Moa; Miriam von Tiedemann; Kenneth C Young; Matthew G Wallis
Journal:  Phys Med Biol       Date:  2013-11-20       Impact factor: 3.609

7.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

8.  Generalized image combinations in dual KVP digital radiography.

Authors:  L A Lehmann; R E Alvarez; A Macovski; W R Brody; N J Pelc; S J Riederer; A L Hall
Journal:  Med Phys       Date:  1981 Sep-Oct       Impact factor: 4.071

9.  Human observer detection experiments with mammograms and power-law noise.

Authors:  A E Burgess; F L Jacobson; P F Judy
Journal:  Med Phys       Date:  2001-04       Impact factor: 4.071

10.  Projection x-ray imaging with photon energy weighting: experimental evaluation with a prototype detector.

Authors:  Polad M Shikhaliev
Journal:  Phys Med Biol       Date:  2009-07-30       Impact factor: 3.609

View more
  3 in total

1.  A framework for performance characterization of energy-resolving photon-counting detectors.

Authors:  Mats Persson; Paurakh L Rajbhandary; Norbert J Pelc
Journal:  Med Phys       Date:  2018-10-12       Impact factor: 4.071

2.  Objective assessment of task performance: a comparison of two FFDM detectors using an anthropomorphic breast phantom.

Authors:  Andrey Makeev; Lynda C Ikejimba; Jesse Salad; Stephen J Glick
Journal:  J Med Imaging (Bellingham)       Date:  2019-10-17

3.  Microcalcification detectability using a bench-top prototype photon-counting breast CT based on a Si strip detector.

Authors:  Hyo-Min Cho; Huanjun Ding; William C Barber; Jan S Iwanczyk; Sabee Molloi
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

  3 in total