Literature DB >> 26015522

Long-term occlusion results with SILK flow diversion in 28 aneurysms: Do recanalizations occur during follow-up?

Anastasios Mpotsaris1, Martin Skalej2, Oliver Beuing2, Bernd Eckert3, Daniel Behme4, Werner Weber5.   

Abstract

BACKGROUND AND
PURPOSE: The purpose of this article is to report on the long-term success rates of Silk flow-diverter (FD) treatment in a multicenter prospective study for the treatment of complex aneurysms.
METHODS: Between May 2008 and January 2011, all consecutive patients featuring complex intracranial aneurysms eligible for FD treatment with the Silk in three neurovascular centers were included. Clinical and imaging data were assessed during hospitalization and follow-up.
RESULTS: Five patients were initially asymptomatic, 20 patients showed various neurological symptoms. Twenty-eight FDs were implanted in 25 patients treating 28 aneurysms. The immediate procedure-related morbidity was 8% (two of 25), mortality 0%. One procedure-related death was observed during follow-up (in-stent thrombosis). Compared to the immediate result nearly two of three aneurysms improved during follow-up; all angiographically confirmed inflow changes took place within six months after treatment. Final anatomic outcome in 24 aneurysms of 22 patients comprised 14 (59%) with complete occlusion, seven (29%) with a neck remnant, two (8%) with residual filling <50%, none with residual filling >50% and one (4%) unchanged in comparison to its pretreatment status. Postinterventional recanalizations were seen in three of 13 (23%) aneurysms treated with FD alone; none were observed in 15 aneurysms treated with adjunctive coiling.
CONCLUSION: Anatomic presentation and location are key for successful FD treatment. The rate of successful occlusion increases during follow-up. Postinterventional monitoring for at least six months is paramount, as anatomic outcome is not reliably predictable and recanalizations may occur in initially completely occluded aneurysms.
© The Author(s) 2015.

Entities:  

Keywords:  Flow diverter; Silk; intracranial aneurysm

Mesh:

Substances:

Year:  2015        PMID: 26015522      PMCID: PMC4757273          DOI: 10.1177/1591019915583119

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  27 in total

1.  Treatment of intra-cranial aneurysms with the SILK flow diverter: 2 years' experience with 28 patients at a single center.

Authors:  Shimon Maimon; Lior Gonen; Erez Nossek; Ido Strauss; Ronen Levite; Zvi Ram
Journal:  Acta Neurochir (Wien)       Date:  2012-03-09       Impact factor: 2.216

2.  Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study.

Authors:  J Berge; A Biondi; P Machi; H Brunel; L Pierot; J Gabrillargues; K Kadziolka; X Barreau; V Dousset; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

3.  Pipeline flow-diverter stent for endovascular treatment of intracranial aneurysms: preliminary experience in 20 patients with 27 aneurysms.

Authors:  Boris Lubicz; Laurent Collignon; Gaï Raphaeli; Olivier De Witte
Journal:  World Neurosurg       Date:  2011 Jul-Aug       Impact factor: 2.104

4.  Intra-aneurysmal thrombosis as a possible cause of delayed aneurysm rupture after flow-diversion treatment.

Authors:  Z Kulcsár; E Houdart; A Bonafé; G Parker; J Millar; A J P Goddard; S Renowden; G Gál; B Turowski; K Mitchell; F Gray; M Rodriguez; R van den Berg; A Gruber; H Desal; I Wanke; D A Rüfenacht
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-11       Impact factor: 3.825

5.  Treatment and follow-up of 22 unruptured wide-necked intracranial aneurysms of the internal carotid artery with Onyx HD 500.

Authors:  Werner Weber; Ralf Siekmann; Bernhard Kis; Dietmar Kuehne
Journal:  AJNR Am J Neuroradiol       Date:  2005-09       Impact factor: 3.825

6.  Treatment of intracranial aneurysms using flow-diverting silk stents (BALT): a single centre experience.

Authors:  M Leonardi; L Cirillo; F Toni; M Dall'olio; C Princiotta; A Stafa; L Simonetti; R Agati
Journal:  Interv Neuroradiol       Date:  2011-10-17       Impact factor: 1.610

7.  High-profile flow diverter (silk) implantation in the basilar artery: efficacy in the treatment of aneurysms and the role of the perforators.

Authors:  Zsolt Kulcsár; Ulrike Ernemann; Stephan G Wetzel; Alexander Bock; Sophia Goericke; Vasilis Panagiotopoulos; Michael Forsting; Daniel A Ruefenacht; Isabel Wanke
Journal:  Stroke       Date:  2010-07-08       Impact factor: 7.914

8.  Treatment of intracranial aneurysms by functional reconstruction of the parent artery: the Budapest experience with the pipeline embolization device.

Authors:  I Szikora; Z Berentei; Z Kulcsar; M Marosfoi; Z S Vajda; W Lee; A Berez; P K Nelson
Journal:  AJNR Am J Neuroradiol       Date:  2010-02-11       Impact factor: 3.825

9.  Complications in the treatment of intracranial aneurysms with silk stents: an analysis of 30 consecutive patients.

Authors:  L Cirillo; M Leonardi; M Dall'olio; C Princiotta; A Stafa; L Simonetti; F Toni; R Agati
Journal:  Interv Neuroradiol       Date:  2012-12-03       Impact factor: 1.610

10.  Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience.

Authors:  Pedro Lylyk; Carlos Miranda; Rosana Ceratto; Angel Ferrario; Esteban Scrivano; Hugh Ramirez Luna; Aaron L Berez; Quang Tran; Peter K Nelson; David Fiorella
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

View more
  9 in total

1.  FRED Flow Diverter: A Study on Safety and Efficacy in a Consecutive Group of 50 Patients.

Authors:  H Luecking; T Engelhorn; S Lang; P Goelitz; S Kloska; K Roessler; A Doerfler
Journal:  AJNR Am J Neuroradiol       Date:  2017-01-19       Impact factor: 3.825

Review 2.  [Management of paraophthalmic aneurysms : Review of endovascular treatment strategies].

Authors:  P Bhogal; M Aguilar Pérez; G Sauder; H Bäzner; O Ganslandt; H Henkes
Journal:  Ophthalmologe       Date:  2018-02       Impact factor: 1.059

3.  Mid-term and long-term follow-up of intracranial aneurysms treated by the p64 Flow Modulation Device: a multicenter experience.

Authors:  Francesco Briganti; Giuseppe Leone; Lorenzo Ugga; Mariano Marseglia; Antonio Macera; Andrea Manto; Luigi Delehaye; Maurizio Resta; Mariachiara Resta; Nicola Burdi; Nunzio Paolo Nuzzi; Ignazio Divenuto; Ferdinando Caranci; Mario Muto; Domenico Solari; Paolo Cappabianca; Francesco Maiuri
Journal:  J Neurointerv Surg       Date:  2016-07-20       Impact factor: 5.836

4.  The Use of Flow Diverting Stents to Treat Para-Ophthalmic Aneurysms.

Authors:  Pervinder Bhogal; Victoria Hellstern; Hansjörg Bäzner; Oliver Ganslandt; Hans Henkes; Marta Aguilar Pérez
Journal:  Front Neurol       Date:  2017-08-07       Impact factor: 4.003

5.  Use of flow diverters in the treatment of unruptured saccular aneurysms of the anterior cerebral artery.

Authors:  P Bhogal; R Martinez Moreno; O Ganslandt; H Bäzner; H Henkes; M Aguilar Perez
Journal:  J Neurointerv Surg       Date:  2016-10-27       Impact factor: 5.836

6.  Endovascular Treatment of Anterior Circulation Aneurysms With the p64 Flow Modulation Device: Mid- and Long-Term Results in 617 Aneurysms From a Single Center.

Authors:  Marta Aguilar Pérez; Elina Henkes; Victoria Hellstern; Carmen Serna Candel; Christina Wendl; Hansjörg Bäzner; Oliver Ganslandt; Hans Henkes
Journal:  Oper Neurosurg (Hagerstown)       Date:  2021-03-15       Impact factor: 2.703

7.  The use of flow diverters to treat small (≤5 mm) ruptured, saccular aneurysms.

Authors:  Pervinder Bhogal; Elina Henkes; Stefan Schob; Muhammad AlMatter; Victoria Hellstern; Hansjörg Bäzner; Oliver Ganslandt; Hans Henkes; Marta Aguilar Pérez
Journal:  Surg Neurol Int       Date:  2018-10-30

8.  Hydrophilic Stent Coating Inhibits Platelet Adhesion on Stent Surfaces: Initial Results In Vitro.

Authors:  Tim Lenz-Habijan; P Bhogal; Marcus Peters; Albrecht Bufe; Rosa Martinez Moreno; Catrin Bannewitz; Hermann Monstadt; Hans Henkes
Journal:  Cardiovasc Intervent Radiol       Date:  2018-07-23       Impact factor: 2.740

9.  Branch vessel occlusion in aneurysm treatment with flow diverter stent.

Authors:  Sophia Hohenstatt; Antonio Arrichiello; Giorgio Conte; Giuseppe Craparo; Ferdinando Caranci; Alessio Angileri; Daniel Levi; Gianpaolo Carrafiello; Aldo Paolucci
Journal:  Acta Biomed       Date:  2020-09-23
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.