Literature DB >> 22300924

Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study.

J Berge1, A Biondi, P Machi, H Brunel, L Pierot, J Gabrillargues, K Kadziolka, X Barreau, V Dousset, A Bonafé.   

Abstract

BACKGROUND AND
PURPOSE: FD stent placement is a promising therapy for challenging intracranial aneurysms. Long-term evaluations about angiographic and morphologic results are still missing. This is the aim of this multicenter series.
MATERIALS AND METHODS: We report our experience and 1-year FU in a retrospective chart review of 65 consecutive subjects with 77 unruptured or recanalized aneurysms that were treated with Silk FD stents at 6 centers in France. Both angiographic and clinical results were recorded before treatment and at 6 and 12 months after treatment. At the 12-month FU, relationships between angiographic aneurysm occlusion and shrinkage of the thrombosed aneurysm sac were evaluated.
RESULTS: Stent deployment was achieved in 64 cases (98.5%) and failed in 1 case (1.5%). Seven misdeployments of the Silk stent caused the occlusion of 6 parent arteries. Overall acute/subacute procedural morbidity was 7.7%, and mortality was zero. Delayed complications were observed in 10.9% of subjects. At the 6-month FU, permanent morbidity was 7.8% and mortality was 3%. Complete occlusion occurred within 6 months in 68% of aneurysms and within 12 months after treatment in 84.5% of aneurysms. At the 12-month FU, in angiographically complete occluded aneurysms, MR imaging/CT analysis showed the complete disappearance of the thrombosed aneurysm in 30% of cases and partial shrinkage in 52%; furthermore, thrombosed aneurysms were stable in 11% of cases and enlarged in 7%.
CONCLUSIONS: The Silk stent is an effective tool for the treatment of challenging aneurysms because it allows complete occlusion in most cases 1 year after treatment. Permanent morbidity was 7.8%, and mortality was 3%.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22300924      PMCID: PMC8013262          DOI: 10.3174/ajnr.A2907

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  23 in total

1.  Aneurysm rupture following treatment with flow-diverting stents: computational hemodynamics analysis of treatment.

Authors:  J R Cebral; F Mut; M Raschi; E Scrivano; R Ceratto; P Lylyk; C M Putman
Journal:  AJNR Am J Neuroradiol       Date:  2010-11-11       Impact factor: 3.825

Review 2.  Personalized approaches to clopidogrel therapy: are we there yet?

Authors:  Christopher D Anderson; Alessandro Biffi; Steven M Greenberg; Jonathan Rosand
Journal:  Stroke       Date:  2010-10-28       Impact factor: 7.914

3.  Perianeurysmal brain inflammation after flow-diversion treatment.

Authors:  J Berge; T Tourdias; J-F Moreau; X Barreau; V Dousset
Journal:  AJNR Am J Neuroradiol       Date:  2011-09-22       Impact factor: 3.825

4.  Alteration of hemodynamics in aneurysm models by stenting: influence of stent porosity.

Authors:  B B Lieber; A P Stancampiano; A K Wakhloo
Journal:  Ann Biomed Eng       Date:  1997 May-Jun       Impact factor: 3.934

5.  High-profile flow diverter (silk) implantation in the basilar artery: efficacy in the treatment of aneurysms and the role of the perforators.

Authors:  Zsolt Kulcsár; Ulrike Ernemann; Stephan G Wetzel; Alexander Bock; Sophia Goericke; Vasilis Panagiotopoulos; Michael Forsting; Daniel A Ruefenacht; Isabel Wanke
Journal:  Stroke       Date:  2010-07-08       Impact factor: 7.914

6.  Endovascular treatment of unruptured aneurysms.

Authors:  D Roy; G Milot; J Raymond
Journal:  Stroke       Date:  2001-09       Impact factor: 7.914

7.  Neuroform stent-assisted coiling of unruptured intracranial aneurysms: short- and midterm results from a single-center experience with 68 patients.

Authors:  I L Maldonado; P Machi; V Costalat; T Mura; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2010-10-21       Impact factor: 3.825

8.  Stent-assisted coiling of intracranial aneurysms: clinical and angiographic results in 216 consecutive aneurysms.

Authors:  Michel Piotin; Raphaël Blanc; Laurent Spelle; Charbel Mounayer; Rhelen Piantino; Paul J Schmidt; Jacques Moret
Journal:  Stroke       Date:  2009-12-03       Impact factor: 7.914

9.  Unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment.

Authors:  David O Wiebers; J P Whisnant; J Huston; I Meissner; R D Brown; D G Piepgras; G S Forbes; K Thielen; D Nichols; W M O'Fallon; J Peacock; L Jaeger; N F Kassell; G L Kongable-Beckman; J C Torner
Journal:  Lancet       Date:  2003-07-12       Impact factor: 79.321

10.  Long-term follow-up of cerebral aneurysms after endovascular therapy prediction and outcome of retreatment.

Authors:  T Ries; S Siemonsen; G Thomalla; U Grzyska; H Zeumer; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2007-09-20       Impact factor: 3.825

View more
  78 in total

Review 1.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review.

Authors:  Xianli Lv; Hongchao Yang; Peng Liu; Youxiang Li
Journal:  Neuroradiol J       Date:  2016-02-02

Review 2.  Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review.

Authors:  Francesco Briganti; Giuseppe Leone; Mariano Marseglia; Giuseppe Mariniello; Ferdinando Caranci; Arturo Brunetti; Francesco Maiuri
Journal:  Neuroradiol J       Date:  2015-08-27

3.  Initial Experience with p64: A Novel Mechanically Detachable Flow Diverter for the Treatment of Intracranial Saccular Sidewall Aneurysms.

Authors:  S Fischer; M Aguilar-Pérez; E Henkes; W Kurre; O Ganslandt; H Bäzner; H Henkes
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

4.  Periprocedural safety of Pipeline therapy for unruptured cerebral aneurysms: Analysis of 279 Patients in a multihospital database.

Authors:  Robert J McDonald; Jennifer S McDonald; David F Kallmes; Giuseppe Lanzino; Harry J Cloft
Journal:  Interv Neuroradiol       Date:  2015-02       Impact factor: 1.610

5.  Flow Diversion for Intracranial Aneurysm Management: A New Standard of Care.

Authors:  Fawaz Al-Mufti; Krishna Amuluru; Chirag D Gandhi; Charles J Prestigiacomo
Journal:  Neurotherapeutics       Date:  2016-07       Impact factor: 7.620

6.  High-flow bypass with radial artery graft followed by internal carotid artery ligation for large or giant aneurysms of cavernous or cervical portion: clinical results and cognitive performance.

Authors:  Hideaki Ono; Tomohiro Inoue; Takeo Tanishima; Akira Tamura; Isamu Saito; Nobuhito Saito
Journal:  Neurosurg Rev       Date:  2017-09-27       Impact factor: 3.042

7.  Silk flow-diverter stent for the treatment of intracranial aneurysms: a series of 58 patients with emphasis on long-term results.

Authors:  B Lubicz; O Van der Elst; L Collignon; B Mine; F Alghamdi
Journal:  AJNR Am J Neuroradiol       Date:  2014-11-06       Impact factor: 3.825

8.  Silk flow-diverter stent for the treatment of complex intracranial aneurysms: A one-year follow-up multicenter study.

Authors:  G Foa Torres; F Roca; A Noguera; J Godes; S Petrocelli; I Aznar; S Ales; P Muszynski; R Maehara; M Vicente; J M Pumar
Journal:  Interv Neuroradiol       Date:  2018-05-02       Impact factor: 1.610

Review 9.  [Management of paraophthalmic aneurysms : Review of endovascular treatment strategies].

Authors:  P Bhogal; M Aguilar Pérez; G Sauder; H Bäzner; O Ganslandt; H Henkes
Journal:  Ophthalmologe       Date:  2018-02       Impact factor: 1.059

10.  Treatment of complex intracranial aneurysms using flow-diverting silk® stents. An analysis of 32 consecutive patients.

Authors:  Ramazan Buyukkaya; Hasan Kocaeli; Nalan Yildirim; Hakan Cebeci; Cüneyt Erdogan; Bahattin Hakyemez
Journal:  Interv Neuroradiol       Date:  2014-12-05       Impact factor: 1.610

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.