Literature DB >> 20616327

High-profile flow diverter (silk) implantation in the basilar artery: efficacy in the treatment of aneurysms and the role of the perforators.

Zsolt Kulcsár1, Ulrike Ernemann, Stephan G Wetzel, Alexander Bock, Sophia Goericke, Vasilis Panagiotopoulos, Michael Forsting, Daniel A Ruefenacht, Isabel Wanke.   

Abstract

BACKGROUND AND
PURPOSE: The introduction of flow diverters (FDs) has expanded the possibilities for reconstructive treatment of difficult intracranial aneurysms. Concern remains as to the long-term patency of the perforating arteries and side branches covered during stent placement. Our purpose was to evaluate the performance of and early effect on covered branches after implantation of the Silk FD in the treatment of basilar artery aneurysms.
METHODS: Twelve patients with an aneurysm of the basilar artery that was treated by implantation of the Silk FD were included in our retrospective study. Both unruptured and previously ruptured, formerly untreated, and recurrent aneurysms were treated. During follow-up, patients were monitored for clinical evolution, patency of the covered vessels, and aneurysmal obliteration.
RESULTS: Of the 2 ruptured aneurysms, 1 was initially treated by FD implantation. The FD covered the basilar bifurcation and the origin of a P1 segment of the posterior cerebral artery in 9 cases, the origin of the superior cerebellar artery in 9, and of the anterior inferior cerebellar artery in 3. There was 1 acute basilar artery occlusion a few hours after FD implantation. During a mean follow-up of 16 weeks, 3 patients experienced a symptomatic neurologic event.
CONCLUSIONS: Implantation of the Silk FD in the basilar artery was feasible and well tolerated in most cases to date. However, late ischemic events affecting perforating arteries may occur after FD implantation, suggesting that the indication should be restricted to otherwise untreatable aneurysms in this location.

Entities:  

Mesh:

Year:  2010        PMID: 20616327     DOI: 10.1161/STROKEAHA.110.580308

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  72 in total

1.  Value of imaging lenticulostriate arteries before middle cerebral artery stenting for the prevention of perforator stroke.

Authors:  Jian-Ren Liu; Min Zhang; Meng-Li Wei
Journal:  Neuroradiology       Date:  2012-07-10       Impact factor: 2.804

2.  Flow-diverter silk stent for the treatment of intracranial aneurysms: 1-year follow-up in a multicenter study.

Authors:  J Berge; A Biondi; P Machi; H Brunel; L Pierot; J Gabrillargues; K Kadziolka; X Barreau; V Dousset; A Bonafé
Journal:  AJNR Am J Neuroradiol       Date:  2012-02-02       Impact factor: 3.825

Review 3.  Flow-diverter devices in the treatment of intracranial aneurysms: A meta-analysis and systematic review.

Authors:  Xianli Lv; Hongchao Yang; Peng Liu; Youxiang Li
Journal:  Neuroradiol J       Date:  2016-02-02

Review 4.  Endovascular treatment of cerebral aneurysms using flow-diverter devices: A systematic review.

Authors:  Francesco Briganti; Giuseppe Leone; Mariano Marseglia; Giuseppe Mariniello; Ferdinando Caranci; Arturo Brunetti; Francesco Maiuri
Journal:  Neuroradiol J       Date:  2015-08-27

5.  Initial Experience with p64: A Novel Mechanically Detachable Flow Diverter for the Treatment of Intracranial Saccular Sidewall Aneurysms.

Authors:  S Fischer; M Aguilar-Pérez; E Henkes; W Kurre; O Ganslandt; H Bäzner; H Henkes
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

6.  Evaluation of a second-generation self-expanding variable-porosity flow diverter in a rabbit elastase aneurysm model.

Authors:  C N Ionita; S K Natarajan; W Wang; L N Hopkins; E I Levy; A H Siddiqui; D R Bednarek; S Rudin
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

7.  Y-crossing of braided stents with stents and flow diverters does not cause significant stenosis in bench-top studies.

Authors:  Alina Makoyeva; Tim E Darsaut; Igor Salazkin; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

8.  Silk flow-diverter stent for the treatment of complex intracranial aneurysms: A one-year follow-up multicenter study.

Authors:  G Foa Torres; F Roca; A Noguera; J Godes; S Petrocelli; I Aznar; S Ales; P Muszynski; R Maehara; M Vicente; J M Pumar
Journal:  Interv Neuroradiol       Date:  2018-05-02       Impact factor: 1.610

Review 9.  [Management of paraophthalmic aneurysms : Review of endovascular treatment strategies].

Authors:  P Bhogal; M Aguilar Pérez; G Sauder; H Bäzner; O Ganslandt; H Henkes
Journal:  Ophthalmologe       Date:  2018-02       Impact factor: 1.059

10.  Pipeline embolization device in aneurysmal subarachnoid hemorrhage.

Authors:  J P Cruz; C O'Kelly; M Kelly; J H Wong; W Alshaya; A Martin; J Spears; T R Marotta
Journal:  AJNR Am J Neuroradiol       Date:  2012-10-11       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.